RESIDENTIAL FIRE SEPARATION CASE STUDY
BELMONT SUBDIVISION Ashburn, Virginia 1994
Belmont Fire Photos Courtesy Melvin Byrne Loudoun County Fire/Rescue Service
Leesburg Ashburn Sterling
433 Single Family Dwellings 425 429 Townhomes Under Construction Not To Scale
433 Single Family Dwellings 425 429 Fire Origin
433 Single Family Dwellings 425 429 Destroyed
433 Single Family Dwellings 425 429 Substantially Damaged
433 Single Family Dwellings 425 429 Minor Damage to Townhouses
6 Feet < 8 Feet Fire Separation Distance
Linked to Drywall Curing Operation in 433 CAUSE OF FIRE
Propane Storage CONTRIBUTING FACTORS: Fire Separation Cedar Shakes
Separation Requirements • 3 Feet From Lot Line or • One Hour Wall
DALE CITY Trentdale
8 FEET WEAK LINK HOUSE
HERITAGE HUNT Gainesville
ZONINGAMENDMENT • 0 Feet Side Yard • 10 Feet Combined
SENTRY RIDGE Manassas
NFPA 80A Recommended practice for fire protection of buildings from exterior fire exposures
NFPA 80A Provides an objective approach for the designer to determine and mitigate fire risk
Fire Risk Determined By: • Building Construction • Opening Protectives • Building Size
Fire Risk Mitigation • Distance Between Buildings • Fire Resistive Construction • Residential Fire Sprinklers
Application Example SD #99-00366 Roseberry Section 1 Lots 12 & 13
Width of Building - 48 ft • Height of Building - 30 ft • Fire Severity - Light • Percent of Openings - 100% Exposure Analysis
Exposure Analysis Table Calculation • 48 ft / 30 ft = 1.6 • Guide number is 1.74 • Separation Distance = (1.74 x 30 ft) + 5 ft = 57 ft
Spatial Separation - Table 2-3 • Construction Improvements • Residential Fire Sprinklers Means of Protection