1 / 1

HVAC Engineering Consultants in Florida

Our HVAC engineering consultants & HVAC designs guarantee code compliance, right temperature, humidity control, comfort and indoor air quality for the occupants in your building, as well as energy efficiency.

chrispizy66
Download Presentation

HVAC Engineering Consultants in Florida

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. HVAC Design & HVAC Consultancy Standard HVAC Designing is done strictly adhering to ASHRAE guidelines. ASHRAE stands for American Society of Heating Refrigeration, & Air Conditioning Engineers) . ASHRAE also publish his Handbook which is followed worldwide to design any kind of HVAC System. In USA, we also have ISHRAE which stands for USA Society of Heating, Refrigeration & Air Conditioner Engineers) While designing HVAC System, architectural drawing layout is must which specify location of each and every material and its respective location. This layout is then provided to HVAC Consultants and they calculate Heat Load of the location they need to cool off. For calculating Heat Load, U Factor(Overall Heat Transmission Coefficient) is calculated for each and every kind of wall material, roof material, equipment’s generating heat. Also, latitude, longitude, Orientation, Direction, Geographical location, Glass area plays a vital role in Heat Load Calculations. Heat Load is calculated generally in terms of BTU (British Thermal Units). Once Heat Load is calculated, cooling tonnage capacity comes into picture which tells about how much value of TR (Tonnage of Refrigeration) machine is required to offset the heat generated in the room. As a thumb rule, 150 square feet area can be cooled by 1 TR of machine. A drawing is then created by draughtman who locate positions of the required cooling machines, cooling accessories, Duct Layout to the Project Engineer. Post this, equipment is selected and then the concerned contractor takes care of execution i.e. SITC( Supply, Installation ,Testing & Commissioning)

More Related