70 likes | 235 Views
EMMA: Summary of Quad and BPM survey data from Jonathan Strachan and Neil Bliss, Nov’10-Feb’11. Ian Kirkman February 10 th 2011. Quad magnet adjustments and surveys, X-axis (along beam). before (end 2010) : -26 microns +/- 142 microns ( StD ) (means)
E N D
EMMA: Summary of Quad and BPM survey data from Jonathan Strachan and Neil Bliss, Nov’10-Feb’11 Ian Kirkman February 10th 2011
Quad magnet adjustments and surveys, X-axis (along beam) before (end 2010) :-26 microns +/- 142 microns (StD) (means) latest (Feb 2nd 2011) :-8 microns +/- 20 microns (StD) note outlier at -3.58mm in data before adjustment (E28-QUAD-01) IK Feb.10th 2011 Slide 1
Quad magnet adjustments and surveys, Y-axis (transverse) before (end 2010) : 110 microns +/- 181 microns (StD) (means) latest (Feb 2nd 2011) :18 microns +/- 55 microns (StD) note outlier at -3.58mm in data before adjustment (E28-QUAD-01) IK Feb.10th 2011 Slide 1
Quad magnet adjustments and surveys, Z-axis (vertical) before (end 2010) : 26 microns +/- 62 microns (StD) (means) latest (Feb 2nd 2011) :-2 microns +/- 25 microns (StD) IK Feb.10th 2011 Slide 1
BPM survey, X-axis (along beam) latest data: 576 microns +/- 732 microns (StD) (mean) IK Feb.10th 2011 Slide 1
BPM survey, Y-axis (transverse) latest data: -394 microns +/- 1063 microns (StD) (mean) IK Feb.10th 2011 Slide 1
BPM survey, Z-axis (vertical) latest data: 229 microns +/- 459 microns (StD) (mean) IK Feb.10th 2011 Slide 1