An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Single-crystal X-ray diffraction at HPCAT D. Popov HPCAT Geophysical Laboratory Carnegie Institution of Washington

  2. Why High-pressure Single Crystal Diffraction? • Reliable structure determination • More precise refinement of crystal structures comparing to powder data • Electron density distribution • Good use of beamtime at Bending Magnet • It is timely, because the high pressure techniques recently become available • Sufficient Q-coverage and completeness (x-ray energy, cell opening). • Matched beamsize to the sample size • Potentials for time resolved studies

  3. HP single-crystal X-ray diffraction requirements • High energy of X-ray: typically >̴30keV • Small x-ray beam • Sufficiently large opening of high pressure cells: more than 60 • Hydrostatic (or close to) pressure medium • Precise sample controls and rotation • Intensity correction procedures • Detector with high dynamic range

  4. HPCAT single-crystal diffraction setup Mar IP Beamstop On-line Ruby system pinhole Sample in gearbox

  5. Evolution of fractional atomic coordinates in Cr2O3

  6. Evolution of Cr-O distances in Cr2O3

  7. Electron density distributions in Si under high pressures

  8. Temperature can be varied! Low temperature > 10K High temperature < 1000K Resistive heating On-line Ruby cryostat pinhole

  9. Time resolved studies of single crystals?

  10. Laue technique is widely used in materials science but rather new in high pressure • Mechanism of phase transitions and transformations • Deformation mechanism • Advantages with respect to application of monochromatic beam • Much faster. • Data collection in time resolved mode is possible. • There is no need to rotate the sample. • No sphere of confusion problem. • Smaller irradiated volume. • Easier to center specific area on a rotation axis. • Much more sensitive to crystal lattice deformation and rotations • Getting d-values • Exchangeable monochromators. • Absorption edges.

  11. HPCAT Laue setup forward geometry channel cut mono detector cover photo diode pinhole CCD sample Lead pieces x/y stage • Resistive heating system • On-line Ruby • Cryostat • Detectors: • MARCCD is used routinely, • test measurements with Perkin Elmer

  12. 90 geometry CCD pinhole DAC photo diode

  13. Commissioning test • Modeling of dislocations arrangements • Modeling of elastic strain gradients

  14. Bent Si wafer X-ray

  15. Bent Si wafer Beam profile 6 7 X ~(110) Z (001) 4 X-ray beam 5 20.5 4 6 2 t Deformation Ɛxx=t/R Ɛzz=ν(t/R)/(ν-1) ν=0.279 1 3 7 R=3.86mm Point 2: a= 5.433 b= 5.434 c= 5.424 γ=89.889 Point 3: a= 5.423 b= 5.422 c= 5.432 γ=90.111 15µm 5 tail tail

  16. Streaks modeling (3-10) (1-31) 7 6 50% of peak intensity 6 (53-1) 7 7 6 (-531) 7 6 (010) (-551) (130) 6 6 7 7 6,7 oversaturated

  17. Tails modeling (3-10) 5 (1-31) 4 3 1 10% of peak intensity 2 4 2 3 1 (53-1) 5 5 1 3 4 2 (-531) 5 3 1 2 4 (-551) (130) (010) 4 4 1 1 2 2 4,5 3 5 3 5

  18. White Laue Technique at HPCAT • Laue diffraction setup is currently available. • Case studies using this setup are in progress. • The setup is intended for time resolved studies.

  19. Summary • High pressure single-crystal X-ray diffraction is implemented routinely at HPCAT in temperature range 10K – 1000K. • Reliable structure determination • Information on geometry of chemical bonds • Electron density distribution • The White Laue technique is promising in time resolved studies of dislocation development and deformation under stress/pressure.