260 likes | 557 Views
Presented by- Biswajit Baruah And Bhaskar Chetia. Pressure Measuring DEVICES. What is Fluid Pressure ?. Fluid contained in a vessel exerts force on all its sides. The force per unit area is called Fluid Pressure. Mathematically- p= P/A where P= the force and
E N D
Presented by- BiswajitBaruah And BhaskarChetia Pressure Measuring DEVICES
What is Fluid Pressure? • Fluid contained in a vessel exerts force on all its sides. The force per unit area is called Fluid Pressure. • Mathematically- p= P/A where P= the force and A= area on which the force acts p= intensity of pressure S.I. unit is N/m2or Pascal
Pressure Head- • Represents the internal energy of a fluid due to the pressure exerted on its container. It may also be called static pressure head or simply static head. • Mathematically, h = p / γ where h=pressure head p=intensity of pressure γ=specific wt. of the liquid Hence, pressure intensity may be expressed in two ways- • As force per unit area & • As an equivalent static head.
Pascal’s Principle: Any change in the pressure of a fluid is transmitted uniformly in all directions throughout the fluid. A small force F1 applied to a piston with a small area produces a much larger force F2 on the larger piston. This allows a hydraulic jack to lift heavy objects.
Devices used for measuring pressure- • Fluid pressure may be measured by following devices- 1. Manometers- (a) Simple manometers- PIEZOMETER, U-TUBE MANOMETER & SINGLE- COLUMN MANOMETER. (b) Differential manometers- U-TUBE DIFFERENTIAL MANOMETER & INVERTED U-TUBE DIFFERENTIAL MANOMETER. 2. Mechanical gauges- BOURDON TUBE PRESSURE GAUGE, DIAPHRAGM PRESSURE GAUGE & VACUUM GAUGE.
MANOMETER- measures pressure at a point in a fluid by balancing the column of fluid by the same or another column of fluid. U-TUBE MANOMETER PIEZOMETER SINGLE-COLUMN MANOMETERS INCLINED VERTICAL
Differential manometers- U-TUBE DIFFERENTIAL MANOMETER INVERTED U-TUBE DIFFERENTIAL MANOMETER
Simple manometers-Consists of a glass-tube whose one end is connected to a point where pressure is to be measured and the other end is exposed to the atmosphere Includes- Piezometers U-tube manometers & Single-column manometers
PIEZOMETER- -It is the simplest form of Manometer,used for measuring moderate pressure.It consist of a Tube,open at one end to the Atmosphere,inwhich,Liquid can rise freely without overflow,theHeight,to which the Liquid rises up in the Tube,gives the Pressure Head directly. p= γ h - -not suitable for measuring Negative Pressure because Air will enter in the pipe through the Tube Disadvantages Cannot be used for measuring large pressures in case of lighter liquids. & Cannot be used for measuring gas pressures Measures gauge pressure only.
U-tube manometer- S2 • "U"-Tube manometer enables the pressure of both liquids and gases to be measured with the same instrument. • The fluid whose pressure is being measured should have a mass density less than that of the manometric fluid and the two fluids must be immiscible. S1 The pressures in the right limb and the left limb above the datum line B-C are equal Pressure head above B-C in the right limb= h2S2 Pressure head above B-C in the left limb = h+h1S1 Equating, h+h1S1= h2S2 OR, h= h2S2 _ h1S1 FOR POSITIVE GAUGE PRESSURE
. S1 U-TUBE MANOMETER S2 FOR NEGATIVE GAUGE PRESSURE The pressures in the right limb and the left limb above the datum line X-X are equal Pressure head above X-X in the right limb= 0 Pressure head above X-X in the left limb = h+h1S1+h2S2 Equating, h+h1S1+h2S2 = 0 OR ,h = _( h1S1+h2S2)
SINGLE-COLUMN MANOMETER (VERTICAL) A>>a S1 Light liquid a= area of crossection A= area of crossection Datum line A x Z1 = a x h2 Or, Z1= (a x h2)/A ............(1) Equating the pressure heads above the datum line Z-Z, h +(h1+ Z1)S1 = (h2+ Z1)S2 or, h = (h2+ Z1)S2 _(h1+ Z1)S1or, h = Z1 (S2_ S1) + h2S2_ h1S1 = { (a x h2)/A } (S2_ S1) + h2S2_ h1S1 As A>>a, so ratio A/a is very very small and can be neglected and above equation becomes, • h = h2S2_ h1S1…………………………………………………… (2) S2 Heavy liquid
#useful for the measurement of small pressures and is more sensitive than the vertical tube.-# Due to inclination the distance moved by the heavy liquid in the right limb is more. Let, l = length of the heavy liquid moved in the right limb, θ = inclination of right limb horizontal and Z2 = vertical rise of liquid in the right limb from X-X= l sin θ Putting the value of Z2 in equation (2) we get, h = l sinθ x S2_h1S1 SINGLE-COLUMN MANOMETER (INCLINED)
Differential U-tube manometer- • a differential manometer is used to measure the difference in pressures between two points in a pipe, or in two different pipes. • -most commonly used types- • 1.U-tube differential manometer. • 2.Inverted U-tube differential manometer
Case 1.Figure (a) below shows a differential manometer whose two ends are connected with two different points A and B at the same level and containing same liquid. We know that the pressures in the left limb and the right limb , above the datum line X-X, are equal Pressure head in the left limb = hA + (h +h1)S1 Pressure head in the right limb = hB + h1S1 + hS Equating, hA + (h +h1)S1 = hB + h1S1 + hS or, hA- hB = h ( S – S1) i.e. difference of pressure head, hA- hB = h ( S – S1)
case 2- Figure (b) below shows a differential manometer whose two ends are connected with two different points A and B at different levels and containing different liquids. We know that the pressures in the left limb and the right limb , above the datum line X-X, are equal Pressure head in the left limb = hA + (h +h1)S1 Pressure head in the right limb = hB + h2S2 + hS Equating, hA + (h +h1)S1= hB + h2S2 + hS or, hA- hB = h ( S – S1) + h2S2 - h1S1 Thus, difference of pressure at A and B, hA- hB = h ( S – S1) + h2S2 - h1S1
Mechanical gauges- • Used for measuring medium and high pressures. • Employs elastic systems such as tubes, diaphragms, bellows,etc. • Types- Bourdon tube pressure gauge. Diaphragm gauge & Vacuum gauge.
Bourdon tube pressure gauge The bourdon tube pressure instrument is one of the oldest pressure sensing instruments in use today. The bourdon tube consists of a thin-walled tube that is flattened diametrically on opposite sides to produce a cross-sectional area elliptical in shape, having two long flat sides and two short round sides. The tube is bent lengthwise into an arc of a circle of 270 to 300 degrees. Pressure applied to the inside of the tube causes distension of the flat sections and tends to restore its original round cross-section. This change in cross-section causes the tube to straighten slightly. Since the tube is permanently fastened at one end, the tip of the tube traces a curve BOURDON TUBE PRESSURE GAUGE that is the result of the change in angular position with respect to the centre. Within limits, the movement of the tip of the tube can then be used to position a pointer to indicate the applied internal pressure.
Diaphragm gauge- • This type of gauge employs a metallic disc or diaphragm instead of a bent tube. This tube or diaphragm is used for actuating the indicating device. Referring to the figure below, when pressure is applied on the lower side of the diaphragm it is deflected upward. This movement of the diaphragm is transmitted to a rack and pinion. The latter is attached to the spindle of needle moving on a graduated dial. The dial can again be graduated in a suitable scale.
Vacuum Gauge- Bourdon gauges discussed earlier can be used to measure vacuum instead of pressure. Slight changes in the design are required for this purpose. Thus, in this case, the tub is bent inwards instead of outwards as in pressure gauges. Vacuum gauges are graduated in millimetres of mercury blow the atmospheric pressure. In such cases, therefore, absolute pressure in millimetres of mercury is the difference between barometer reading and vacuum gauge reading. Vacuum gauges are used to measure the vacuum in the condensers, etc. if there is leakage the vacuum will drop.