1 / 13

SWR Meter/Low Pass Filter Session 4

SWR Meter/Low Pass Filter Session 4. SWR Meter Calibration Methods Discussed Finish SWR meter Start the Low Pass Filter Project. SWR Meter Calibration. SWR = [1+x]/[1-x] where x = Sqrt(P R /P F ). P R is the Forward Power P F is the Reverse Power.

Download Presentation

SWR Meter/Low Pass Filter Session 4

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SWR Meter/Low Pass FilterSession 4 SWR Meter Calibration Methods Discussed Finish SWR meter Start the Low Pass Filter Project

  2. SWR Meter Calibration SWR = [1+x]/[1-x] where x = Sqrt(PR/PF) PR is the Forward Power PF is the Reverse Power We get PR and PF from the SWR meter

  3. SWR Meter Calibration Forward Calibration Balance Assumed…see manual Several Methods Possible • Make a look up table based on LTSPICE • Make a look up table based on precision measurements • Use 1 or 2 but create a graph to read SWR • Use analog meters like the conventional cross meter type • Use 1.5:1 , 2:1 and 3:1 loads….very easy Read TCA March/April 2012 on SWR/Power Meters,VA3DDN QST April 2012 on Power Meters..the old basic meter

  4. SWR Meter Calibration R4=R3 =0

  5. Example Calculation VF = 2.7 VR= 0.50 PF = 10 PR = .50 Then x = SQRT(PR/PF) = 0.22 and SWR = 1.57 SWR Meter Calibration R4=R3 =0

  6. T50-6 Low Pass Filter14 MHz Application 9 Turns 8 Turns Output INPUT

  7. Low Pass Filter14 MHz ApplicationSecond and Third Harmonics Attenuated 45 dB

  8. Low Pass Filter ELSIE14 MHz ApplicationSecond and Third Harmonics Attenuated > 40 dB

  9. Low Pass Filter MeasurementsAIM 4170

  10. Low Pass Filter MeasurementsHP Analyzer VE3ZRK

  11. Simulation • Put the supplied filter file into a folder on your computer 2. The file name is VE3KLCauerLowPass14mHzappVersion2.LCT 3. Open up the Elsie Program 4. Click Retrieve Old Design then open the file above 5. Click Schematic if not opened to start the process 6. Click Plot 7. Now experiment with the filter plot options and other windows

  12. Construction • Build each resonator and test with AIM 4170 Put capacitors close to the coils. See my models Leave lots of wire on inductors as before Rewind coils if necessary: 9 turns and 8 turns # 26 Gauge wire. I have lots of wire and toroids 2. Now label the input/output ports of the circuit board with supplied label 3. Wire the series parts first, then solder the parallel capacitors 4. Measure the SWR with the AIM meter

  13. Can improve SWR meter by using matched diodes and transformers. Use 1% resistors. Good example of Ferrites • Low Pass Filter good for filtering square waves Good example of Powdered Iron (High Q) Summary