90 likes | 233 Views
Losses and fabrication tolerances. S. Verdú -Andrés June 10, 2014. SPS DQWCC - Interfaces. RF-seal copper ring gasket for all the ports. Distance from cavity center.
E N D
Losses and fabrication tolerances S. Verdú-Andrés June 10, 2014
SPS DQWCC - Interfaces RF-seal copper ring gasket for all the ports. Distance from cavity center. Includes anomalous effect of copper at cryo temperatures (Rs 0.008 Ohm) and surface roughness effects on surface resistance (x1.3). Are all the gaskets at cryo temperature?
SPS DQWCC – Dissipated power at 3mm Cu gasket • BEAM PORT FLANGE CONNECTION Value corresponding to gasket position at 270mm (270273mm) • Anomalous effect of copper at cryo temperatures (Rs 0.008 Ohm) and • surface roughness effects on surface resistance (x1.3). FPC and beam pipe: fine hexa mesh (100/80) CST simulation "F:\CST\DQWCC for SPS\FPC Design - Revisited\SPS-EDQWCC_Finalization - TunedV16f nFPC-19 - FineMesh.cst"
SPS DQWCC – Dissipated power at 3mm Cu gasket • FPC PORT FLANGE CONNECTION • Anomalous effect of copper at cryo temperatures (Rs 0.008 Ohm) and • surface roughness effects on surface resistance (x1.3).
SPS DQWCC – Dissipated power at 3mm Cu gasket • Pickup FLANGE CONNECTION • Anomalous effect of copper at cryo temperatures (Rs 0.008 Ohm) and • surface roughness effects on surface resistance (x1.3).
SPS DQWCC – FPC hook design • (5 May 2014) Power dissipation with ACE3P: 141W and Qext = 5.39 e5 • Revisit FPC design: • Increase coupling by making hook wider – multipacting • - Other suggestions? • Multipacting studies, thermal studies • Fabrication tolerances: penetration, rotation, etc. • HFSS simulation with surface loss density for FPC hook version presented in the Review is ready. Does it seem convenient to study thermal?
SPS DQWCC – Fabrication Tolerances The two most sensitive geometry parameters for the cavity are height and waist, which gives 0.5% and 0.3% change in frequency with 1 mm of fabrication error.
SPS DQWCC – Fabrication Tolerances (*) Cavity with no tubes (**) Cavity with no tubes. Model must be modified to sweep the parameter under study so that more than one parameter does not change with the sweep. (***) Cavity with tubes.
SPS DQWCC – Frequency check points Generated for frequency check points before operation in SPS. The cavity will operate at 400.79 MHz under 2 K.