Troubleshooting

Troubleshooting. General. When an alarm message/fault occurs, the UV lamp switches off and cools down for 2 minutes before re-starting. Clearing the alarm message is done from the RTRun software: Tools > UV Dryer > UV Alarm On/Off. Alarm Messages. Machine Emergency Stop:

conlan
Download Presentation

Troubleshooting

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Troubleshooting

  2. General • When an alarm message/fault occurs, the UV lamp switches off and cools down for 2 minutes before re-starting. • Clearing the alarm message is done from the RTRun software:Tools > UV Dryer > UV Alarm On/Off Confidential

  3. Alarm Messages • Machine Emergency Stop: • An Emergency stop has occurred on the machine. Confidential

  4. Alarm Messages (Cont.) • Shutter Failed to Close: Confidential

  5. Alarm Messages (Cont.) • Shutter Failed to Close (Cont.): • Check that the UV lamp plug is connected to XPPT. • Check that the pneumatic air tube is connected to lamp head. • Check the shutter switch inside the lamp head and all electrical connections/wiring. • Check the 24VDC power supply in the UV electrical cabinet. Confidential

  6. Alarm Messages (Cont.) • Shutter Failed to Open: Confidential

  7. Alarm Messages (Cont.) • Shutter Failed to Open (Cont.): • Check that the UV lamp plug is connected to XPPT. • Check that the pneumatic air tube is connected to lamp head. • Check the shutter switch inside the lamp head and all electrical connections/wiring. • Check the 24VDC power supply in the UV electrical cabinet. Confidential

  8. Lamp Alarm Messages (Cont.) • Lamp Over Temperature: Confidential

  9. Alarm Messages (Cont.) • Lamp Over Temperature (Cont.): • Check that the UV lamp plug is connected to XPPT. • Check that the water tubes are connected and that the cooler is running, without any problems. • Check the electrical connections and wiring. Confidential

  10. Lamp Alarm Messages (Cont.) • Lamp Power Fault: Confidential

  11. Alarm Messages (Cont.) • Lamp Power Fault (Cont.): • During the lamp’s “burn-in” stage, if its current does not exceed 70A after 2 minutes, the lamp switches off and the alarm message appears. • Check the connection between the UV lamp head and the UV electrical cabinet. • Check if the lamp is not broken. • Verify that the four high voltage relays in the UV electrical cabinet are enabled during the “burn-In” stage. Confidential

  12. Lamp Alarm Messages (Cont.) • Lamp Pressure Alarm: Confidential

  13. Alarm Messages (Cont.) • Lamp Pressure Alarm (Cont.): • Verify that the extraction fan ducts, on top of the lamp head, are secured. • Verify that the extraction fan rotates in clockwise direction. • Check the electrical connections and wiring. Confidential

  14. Alarm Messages (Cont.) • Extract Fan Trip: Confidential

  15. Alarm Messages (Cont.) • Extract Fan Trip (Cont.): • Verify that the fan circuit breaker (Q7 inside the UV electrical cabinet) is On. • Check all electrical connections and wiring. Confidential

  16. Alarm Messages (Cont.) • Cooler Pump/Fan Trip: Confidential

  17. Alarm Messages (Cont.) • Cooler Pump/Fan Trip (Cont.): • Verify that the cooler pump circuit breaker(Q6.11 inside the UV electrical cabinet) is On. • Verify that the cooler Fan 1 circuit breaker(Q6.12 inside the UV electrical cabinet) is On. • Verify that the cooler Fan 2 circuit breaker(Q6.13 inside the UV electrical cabinet) is On. • Check the electrical connections and wiring of plug XPC2(from cooler to UV electrical cabinet). Confidential

  18. Alarm Messages (Cont.) • Cooler Over Temperature: Confidential

  19. Alarm Messages (Cont.) • Cooler Over Temperature (Cont.): • Verify that all water connections are secure and there are no leaks. • Check the temperature switch connections and wiring. • Check the electrical connections and wiring of plug XPC2(from cooler to UV electrical cabinet). • Check all electrical connections and wiring. Confidential

  20. Alarm Messages (Cont.) • Cooler Low Level: Confidential

  21. Alarm Messages (Cont.) • Cooler Low Level (Cont.): • Check the cooler’s water level. • Verify that all water connections are secure and there are no leaks. • Check the electrical connections and wiring of plug XPC2(from cooler to UV electrical cabinet). • Check all electrical connections and wiring. Confidential

  22. Alarm Messages (Cont.) • Reflector Open Check Lamp Safety Switch: Confidential

  23. Alarm Messages (Cont.) • Reflector Open Check Lamp Safety Switch (Cont.): • Verify that the lamp reflector is in closed position. • Check the safety switch and the electrical connections and wiring of plug XPLH (from the UV lamp head to UV electrical cabinet). • Verify that the safety relay K9 is energized and green LED is lit. If the orange LED is lit, the safety relay is not energized. Confidential