Troubleshooting. General. When an alarm message/fault occurs, the UV lamp switches off and cools down for 2 minutes before re-starting. Clearing the alarm message is done from the RTRun software: Tools > UV Dryer > UV Alarm On/Off. Alarm Messages. Machine Emergency Stop:
E N D
General • When an alarm message/fault occurs, the UV lamp switches off and cools down for 2 minutes before re-starting. • Clearing the alarm message is done from the RTRun software:Tools > UV Dryer > UV Alarm On/Off Confidential
Alarm Messages • Machine Emergency Stop: • An Emergency stop has occurred on the machine. Confidential
Alarm Messages (Cont.) • Shutter Failed to Close: Confidential
Alarm Messages (Cont.) • Shutter Failed to Close (Cont.): • Check that the UV lamp plug is connected to XPPT. • Check that the pneumatic air tube is connected to lamp head. • Check the shutter switch inside the lamp head and all electrical connections/wiring. • Check the 24VDC power supply in the UV electrical cabinet. Confidential
Alarm Messages (Cont.) • Shutter Failed to Open: Confidential
Alarm Messages (Cont.) • Shutter Failed to Open (Cont.): • Check that the UV lamp plug is connected to XPPT. • Check that the pneumatic air tube is connected to lamp head. • Check the shutter switch inside the lamp head and all electrical connections/wiring. • Check the 24VDC power supply in the UV electrical cabinet. Confidential
Lamp Alarm Messages (Cont.) • Lamp Over Temperature: Confidential
Alarm Messages (Cont.) • Lamp Over Temperature (Cont.): • Check that the UV lamp plug is connected to XPPT. • Check that the water tubes are connected and that the cooler is running, without any problems. • Check the electrical connections and wiring. Confidential
Lamp Alarm Messages (Cont.) • Lamp Power Fault: Confidential
Alarm Messages (Cont.) • Lamp Power Fault (Cont.): • During the lamp’s “burn-in” stage, if its current does not exceed 70A after 2 minutes, the lamp switches off and the alarm message appears. • Check the connection between the UV lamp head and the UV electrical cabinet. • Check if the lamp is not broken. • Verify that the four high voltage relays in the UV electrical cabinet are enabled during the “burn-In” stage. Confidential
Lamp Alarm Messages (Cont.) • Lamp Pressure Alarm: Confidential
Alarm Messages (Cont.) • Lamp Pressure Alarm (Cont.): • Verify that the extraction fan ducts, on top of the lamp head, are secured. • Verify that the extraction fan rotates in clockwise direction. • Check the electrical connections and wiring. Confidential
Alarm Messages (Cont.) • Extract Fan Trip: Confidential
Alarm Messages (Cont.) • Extract Fan Trip (Cont.): • Verify that the fan circuit breaker (Q7 inside the UV electrical cabinet) is On. • Check all electrical connections and wiring. Confidential
Alarm Messages (Cont.) • Cooler Pump/Fan Trip: Confidential
Alarm Messages (Cont.) • Cooler Pump/Fan Trip (Cont.): • Verify that the cooler pump circuit breaker(Q6.11 inside the UV electrical cabinet) is On. • Verify that the cooler Fan 1 circuit breaker(Q6.12 inside the UV electrical cabinet) is On. • Verify that the cooler Fan 2 circuit breaker(Q6.13 inside the UV electrical cabinet) is On. • Check the electrical connections and wiring of plug XPC2(from cooler to UV electrical cabinet). Confidential
Alarm Messages (Cont.) • Cooler Over Temperature: Confidential
Alarm Messages (Cont.) • Cooler Over Temperature (Cont.): • Verify that all water connections are secure and there are no leaks. • Check the temperature switch connections and wiring. • Check the electrical connections and wiring of plug XPC2(from cooler to UV electrical cabinet). • Check all electrical connections and wiring. Confidential
Alarm Messages (Cont.) • Cooler Low Level: Confidential
Alarm Messages (Cont.) • Cooler Low Level (Cont.): • Check the cooler’s water level. • Verify that all water connections are secure and there are no leaks. • Check the electrical connections and wiring of plug XPC2(from cooler to UV electrical cabinet). • Check all electrical connections and wiring. Confidential
Alarm Messages (Cont.) • Reflector Open Check Lamp Safety Switch: Confidential
Alarm Messages (Cont.) • Reflector Open Check Lamp Safety Switch (Cont.): • Verify that the lamp reflector is in closed position. • Check the safety switch and the electrical connections and wiring of plug XPLH (from the UV lamp head to UV electrical cabinet). • Verify that the safety relay K9 is energized and green LED is lit. If the orange LED is lit, the safety relay is not energized. Confidential