1 / 11

Payload Regolith Collection, Orientation and Thermal Dynamics

Payload Regolith Collection, Orientation and Thermal Dynamics. Marc Gallant. Presentation Outline. General Payload Requirements Instrument Requirements Regolith Collection Orientation Thermal Dynamics Future Work. General Payload Requirements. “Shall survive launch and impact…”

conor
Download Presentation

Payload Regolith Collection, Orientation and Thermal Dynamics

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Payload Regolith Collection, Orientation and Thermal Dynamics Marc Gallant

  2. Presentation Outline • General Payload Requirements • Instrument Requirements • Regolith Collection • Orientation • Thermal Dynamics • Future Work Marc Gallant

  3. General Payload Requirements • “Shall survive launch and impact…” • Vibration • 5,000 to 16,000 g’s [TBC] • “Shall conform to micro-penetrator…” • Mass: 2.5 kg [TBC] • Volume : 1500 cm3 [TBC] • Power: 5 W [TBC] Marc Gallant

  4. Instrument Requirements • “Shall make two types of measurements…” • Collect regolith • “Shall measure depth of penetration…” • Measure orientation • “Shall report upon thermal dynamics…” • Measure temperature changes Marc Gallant

  5. RegolithExtractionBiomimetic vs. Rotary Drill Drill stem Bevel gear Auger Pinion gear 105 mm Sample chamber Drill motor Pin and crank Drill bit Ref: Gao et al. 39 mm Marc Gallant

  6. RegolithExtraction Marc Gallant

  7. RegolithExtraction Marc Gallant

  8. Orientation“Shall have a range of ±30° or greater” • Spectron™ L Series tilt meter • Range ±45° • Qualified for operation @ -54 °C • Supplier contacted (power, loading) Ref: www.spectronsensors.com Marc Gallant

  9. Thermal Dynamics • “…range of 300 to 400 K [TBC]” • “…time constant < 0.1 s [TBC]” • Combination of requirements difficult to accomplish • No suitable COTS components found • Betatherm™ supplies space-rated components • Contacted about custom thermocouples Marc Gallant

  10. Future Work • Final selection of… • Drill type • Tilt meter • Thermocouples • Verify… • Mass, volume and power • Operational order and duration • Layout Marc Gallant

  11. Questions?

More Related