The Smartest Line-Interactive UPS with Pure Sine Wave Output in High Frequency Technology

JPX. The Smartest Line-Interactive UPS with Pure Sine Wave Output in High Frequency Technology. Features. Microprocessor controlling High Frequency Design with High Power Density Boost and Buck voltage regulation Pure Sine Wave Output Selectable output voltage via front panel

Download Presentation

The Smartest Line-Interactive UPS with Pure Sine Wave Output in High Frequency Technology

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. JPX The Smartest Line-Interactive UPS with Pure Sine Wave Output in High Frequency Technology

  2. Features • Microprocessor controlling • High Frequency Design with High Power Density • Boost and Buck voltage regulation • Pure Sine Wave Output • Selectable output voltage via front panel • Selectable operating mode via front panel • Provide Overload, Short-Circuit, Overheat and Fan fail Protection. • Available to connect external battery cabinet to extend the backup time • Hot-Swappable / User replaceable battery design

  3. Features • Available for various installation environment with individual UPS & EBM case • Output THD<5% with PFC load under Battery Mode • Intelligent Slot for SNMP monitoring • Available for 19” rack installation above 1.5Kva • Green Power function to save battery energy with no load • Smart RS232 and USB communication port • Available to switch on UPS without battery • EPO switch for operation safety

  4. Models • R750/500: Slim Type with 1U High • 1000: Mini-Tower Type

  5. Models • 1500/2000VA: 19” Tower-Rack 2-in-1. UPS and EBM is in different chassis. 2U High.

  6. Models • 3000VA: 19” Tower-Rack 2-in-1. 2U High.

  7. Specification

  8. Specification

  9. Rear Panel - 750/1Kva • Input Power Cord • Outlets • RS232 • USB • RJ11/RJ45 connector T1000 R750

  10. Rear Panel – 1.5/2Kva • Inlet • External Outlets • SNMP Slot • RS232 UPS EBM • USB • External Battery Connector • EPO Connector • RJ11/RJ45

  11. Rear Panel – 3Kva • Inlet • Outlets • SNMP Slot • RS232 • USB • Output NFB • External Battery Connector • EPO Connector • RJ11/RJ45

  12. LED Panel • ON/OFF Switch • Self-Test/Silence • Configuration Key • Enter Key • Load Level • Battery Level • Fault LED • Bad Battery LED • OPV Indicator • Operating mode indicator • Line Mode LED • Battery Mode LED

  13. Selectable Output Voltage • The JPX provides the configuration key to let the user select the suitable output voltage by himself for 220Vac or 230Vac or 240Vac.

  14. Selectable Operating Mode • The JPX also provides the function to let the user to setup the acceptable operating mode for its application. • Normal: Acceptable AC input voltage for +/-20%. • Generator: No change to voltage window. However, the low frequency transfer point is changed to 40Hz and there is no limitation for high frequency transfer point. • Wide Range: The acceptable AC input voltage will be changed to -30% ~ +20%. But the AVR transfer point would be not changed.