DICOM N-Dimensional Presentation State Description and Call for Participation

DICOM N-Dimensional Presentation State Description and Call for Participation. Joe Luszcz. Philips Ultrasound. January 4, 2011. What is Presentation State?. A “recipe” describing a particular presentation (display) of a data object.

dana
Download Presentation

DICOM N-Dimensional Presentation State Description and Call for Participation

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. DICOM N-Dimensional Presentation StateDescription and Call for Participation Joe Luszcz Philips Ultrasound January 4, 2011

  2. What is Presentation State? • A “recipe” describing a particular presentation (display) of a data object. • According to DICOM, 2D Presentation State includes capabilities for specifying: • the output grayscale space in P-Values • the color output space as PCS-Values • grayscale contrast transformations including modality, VOI and presentation LUT • mask subtraction for multi-frame grayscale images • selection of the area of the image to display and whether to rotate or flip it • image and display relative annotations, including graphics, text and overlays • the blending of two image sets into a single presentation

  3. 2D Example:Blending Presentation State Pipeline

  4. Application of Presentation State • Data objects may contain certain attributes as a “default Presentation State” • A separate Presentation State object referencing the data object overrides the default presentation state attributes within the referenced data object

  5. Enhanced DICOM Objects change the game • Many modalities have created “Enhanced” data objects which allow the specification of 3D and 4D data sets (MR, CT, XA, PET, US, …) • These 3D/4D datasets may be presented (viewed) as • A collection of spatially-related frames • Displayed one at a time, as in a light box display • Sequentially, in “fly-through” display • A Multi-Planar Reformatting (MPR) view, which is a derived slice obliquely through the volume dataset • Volume Rendering, which is a view of the volume dataset from a specified viewport and orientation

  6. Example: Ultrasound Display3 MPR + Volume Rendering Views

  7. 3D Workflow • These derived views may be exchanged as 2D objects linked to the source volume data objects • Need a way to represent the “recipe” for creating these 2D views of volume data objects so the viewing operation may be replicated on a different system and/or at a different time

  8. Example 3D Image Review Workflow • Clinician reviews a 2D derived view on a PACS • Decides to reposition the slice or viewport or change processing • 2D object links to the Presentation State object, which provides the recipe and a link to the source volume data • Workstation uses the recipe to regenerate the same 2D view • Clinician uses workstation controls to modify presentation parameters starting from the same point as the original 2D view

  9. What’s happening withinDICOM working groups • Working Group 11 (Presentation State) has a work item to create a general (not modality specific) n-Dimensional Presentation State object • Working Groups 2 (X-Ray Angiography) and 12 (Ultrasound) are collaborating • Need to understand use cases and requirements for all DICOM imaging modalities • Other imaging modalities need to participate if they want a say in the creation of nD PS objects

  10. Ultrasound Requirements for nD Presentation State • Display layout • Intensity settings • Cropping and sculpting • Scaling • Slicing (MPR) • Rendering • Enhanced Blending Pipeline (sup43) • Text and Graphic Annotation • Identification of Anatomic Views

  11. Toshiba’s nD Presentation State Requirements • Annotations • Segmentation • LUT • MPR • Curvilinear Reformat • Volume Rendering • Synchronization

  12. Standardization Challenges • Distinguishing open-system capabilities from proprietary • Open: MPR plane position/orientation, Render viewport • Proprietary: Certain rendering or edge enhancement algorithms • Maximizing similarity of source and review presentations without disclosing trade secrets • Maximizing commonality while recognizing unique modality features

  13. Standardization Challenges

  14. Call for Participation • In the best interest of vendors and clinicians for all modalities to participate • Desired minimum level of participation • Use Cases • Requirements • Test Cases • Better • Participate in Derivation of the Standard

  15. References • DICOM ps3.4 Annex N: Softcopy Presentation State (2D only) • Toshiba White Paper “Volumetric Data Elements”, 17 May 2010 • Ultrasound White Paper “Ultrasound nD Presentation State Requirements”, 4 Aug 2010