110 likes | 122 Views
www.omega-usa.com. 1401 Valley View Lane Irving, TX 75061. 41-15208 Test Tool for Externally Controlled Compressors. JANUARY 2010. Denso and Sanden compressors can be tested with the CLT. Denso: 7SEU16 6SEU14 5SE09C. Sanden: PXE 13 PXE 16. 7SEU17 6SEU16 5SER09.
E N D
www.omega-usa.com 1401 Valley View Lane Irving, TX 75061 41-15208 Test Tool for Externally Controlled Compressors JANUARY 2010
Denso and Sanden compressors can be tested with the CLT • Denso: • 7SEU16 • 6SEU14 • 5SE09C • Sanden: • PXE 13 • PXE 16 • 7SEU17 • 6SEU16 • 5SER09 These models can be found in BMW, Mercedes, Toyota and VAG cars
Piston Shoe Pin Main shaft Rotor Mechanical torque limiter EMPCV No Clutch Reduce spring Orifice Cam Swash plate The valve is regulated by the board electronic…. …these signals are hard to measure
CLT1 supports two areas • Identifying the root cause • Right Diagnosis • Systematical search • Minimizing the costs • Service level • Quicker service • Better cost coverage
The tester improves the diagnosis and thereby save money • It eliminates the wrong diagnosis • You do not need to guess • It saves time • The variable area of the compressor can be tested. • It saves money
You can run the compressorwithout removing it! • Just jack out the compressor connector • Connect simulator on the free cable • Connect CLT to the compressor • Connect Power supply to the vehicle battery • The compressor is now ready to be run and pressure to be tested
The simulator prevent the board electronic to generate and save fault messages Clearing the fault memory is a time consuming activity avoided by connecting the simulator
The CLT 1 is easy to connect Compressor cable Power supply cable 2-polig 3-polig
Open circuit and over load are directly indicated OC = ”Open Circuit” = ”Poor contact.Carefully knock 2-3 times on the valve The diode still indicates – change compressor OL = ”Over Load” = Short cut Change compressor directly
Control the compressor effect with the CLT Time consumption:5 min to connect everything. Max 10 to test! Result within 15 minutes!!! Change the effect with the + / - buttons. You can directly see if the compressor react or not!