1 / 23

Free walls, roofs and billboards

Free walls, roofs and billboards. Wind loading and structural response Lecture 22 Dr. J.D. Holmes. Free walls, roofs and billboards. free-standing walls. elevated walls and billboards. free roofs and canopies. Free walls, roofs and billboards. attached canopies. solar panels. C D = 1.2.

Download Presentation

Free walls, roofs and billboards

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Free walls, roofs and billboards Wind loading and structural response Lecture 22 Dr. J.D. Holmes

  2. Free walls, roofs and billboards • free-standing walls • elevated walls and billboards • free roofs and canopies

  3. Free walls, roofs and billboards • attached canopies • solar panels

  4. CD = 1.2 CD = 1.1 Ground Ground TWO-DIMENSIONAL WALL SQUARE WALL Free walls, roofs and billboards free-standing walls • wind at 90o to plane of wall (lecture 8, Chapter 4) reference U taken as Uh (top of wall)

  5. Free walls, roofs and billboards free-standing walls • wind at 90o to plane of wall (lecture 8, Chapter 4) reference U taken as Uh (top of wall)

  6. 4 3 2 1 0 Maximum Cpn Mean b h 0.1110 100 b/h Free walls, roofs and billboards free-standing walls • wind at 90o to plane of wall Jensen Number (h/zo) = 50 to 160

  7. 4 3 2 1 0 Maximum Cpn b h Mean 0.1 1 10100 b/h Free walls, roofs and billboards free-standing walls • wind at 45o to plane of wall Jensen Number (h/zo) = 50 to 160

  8. 1.0 1.6 b/h=2 b/h=3 1.4 0.7 1.9 b/h=5 1.1 b/h=10 2.2 1.6 0.8 0.6 0.4 2.7 1.8 1.4 1.1 1.0 0.8 0.7 0.6 Free walls, roofs and billboards free-standing walls • wind at 45o to plane of wall mean Cpn Net pressure difference high for first 1-2 wall heights from windward end

  9. 4 3 2 1 0 225 no corner 45 y 45 Cpn corner 45 infinite 45 corner 225 no corner 225 0.1 1 10 100 y/h Free walls, roofs and billboards free-standing walls • wind at 45o to plane of wall mean Cpn Effect of corner is to reduce largest net pressure

  10. s • wind at 0o to plane of walls h Shielding Free walls, roofs and billboards Parallel free-standing walls (noise barriers on urban freeways) significant shielding effects up to 10 wall heights separation

  11. = = Free walls, roofs and billboards Billboards • wind at 0o to plane of board mean Cpn Cpn 1.5 effect of elevation : increase magnitude of mean net pressure coefficient

  12. 2c 1.5 1.1 c 45o c Ground Free walls, roofs and billboards Billboards • wind at 45o to plane of board mean Cpn

  13. Free walls, roofs and billboards New table proposed for ASCE-7-05 • Solid freestanding walls and solid signs • Force coefficients Cf given as function ofclearance ratio,s/h, and aspect ratio, B/s

  14. Free walls, roofs and billboards Walls on bridges • wind at 0o to plane of wall Coefficients based onU at top of wall : little effect of s/h ratio

  15. pnet flat pnet pitched pnet troughed Free walls, roofs and billboards Free-standing roofs Usual convention : positive net pressure is downwards

  16. pnet Free walls, roofs and billboards Free-standing roofs

  17. pnet Free walls, roofs and billboards Free-standing roofs Effect of stored goods : flow stagnates underneath - pnet goes more negative

  18. d=9.3m Free walls, roofs and billboards Free-standing roofs pitched - full scale upper surface pressures dominate - especially near the ridge

  19. Free walls, roofs and billboards Free-standing roofs pitched - model tests high positive and negative values for roof pitches of 22.5o and 30o Cpn averaged over half a roof

  20. -4.0 -3.0 -2.0 -1.0 0.0 wc Cpn hc/h =1 h hc or 4.0, whichever is the lesser hc/h=0.75 or 4.0, whichever is the lesser hc/h=0.5 0.0 0.5 1.0 1.5 2.0 2.5 3.0 Canopy height-to-width ratio,hc/wc Free walls, roofs and billboards Attached canopies (over loading bays etc.) zero pitch - model scale when mounted near the top of the wall, uplift force is high

  21. l   d e h2 c h1 w Free walls, roofs and billboards Solar panels on roofs of buildings wind loads are affected by many parameters :

  22. Free walls, roofs and billboards Solar panels • ‘stand-off’ distance reduces net load normal to roof • higher roof pitch produces less uplift force • panel near eaves or gable ends experience higher loads • generally better to mount parallel to roof slope ( = 0)

  23. End of Lecture 22John Holmes225-405-3789 JHolmes@lsu.edu