130 likes | 316 Views
RollMap & RollSNMP Quick Setup Guide Nikolaos Katsampekis. RollMap LogServer PC. All frames wired With Ethernet and RollNet segments. Control. RollMap. local host. RollCall Control Panel. 2050. LogServer PC. RollCall Proxy (Ctrl). 2052. Logging. Network 1000 Regions
E N D
RollMap & RollSNMP Quick Setup Guide Nikolaos Katsampekis
RollMap LogServer PC All frames wired With Ethernet and RollNet segments Control RollMap local host RollCall Control Panel 2050 LogServer PC RollCall Proxy (Ctrl) 2052 Logging Network 1000 Regions 1100=Region 1 1200=Region 2 1300=Region 3 1400=Region 4 1500=Region 6 1600=Region 7 ………… etc SNMP Logging Ethernet Network IQ Frames 2050 RollSNMP 2056 Thumbnail Service 2064 S&W Hyperion 3U\1U Frames 2601
RollMap Client PC All frames wired With Ethernet and RollNet segments Control RollMap LogServer RollCall Control Panel 2050 LogServer PC RollCall Proxy (Ctrl) 2052 Logging Network 1000 Regions 1100=Region 1 1200=Region 2 1300=Region 3 1400=Region 4 1500=Region 6 1600=Region 7 ………… etc SNMP Logging Ethernet Network IQ Frames 2050 RollSNMP 2056 Thumbnail Service 2064 S&W Hyperion 3U\1U Frames 2601
Proxy Connecting to Frames -At Proxy Set Connections from RollMap to 2053 -At Proxy Set Connections from RollCall to 2050 -At Proxy Add new Ethernet Frames under “Map Connections to Ethernet Chassis”
16 bit/32Bit RollCall Connecting to Proxy 16 Bit RollCall -At Commtrol Select File-> Configure Comms 32 Bit RollCall -Select Build Network (First Icon on Toolbar)
RollSNMP Connecting to LogServer -The RollSNMP service (running at port 2060) Connects silently (running the correct script and drivers) through port 2056 to the LogServer application
RollMap Connecting to 16/32 Bit LogServer and Proxy At RollMap Select File-> Configuration->LogServer Setup At LogServer16 Select Configuration-> Polling Parameters LogServer 16 LogServer 32 One LogServer Only At LogServer32 Select System LogServer 32 Proxy
Frames Passing Information to LogServer At Commtrol Select File -> Unit Name At Gateway card Select LogServer-> Enter Name of LogServer, Select Named LogServer option and enable the correct connection method One LogServer Only
Modules Passing Information to Gateway At each Module card Select the Logging setup Section and enable the Logging checkboxes. Note: All new modules have Logging enabled by default.
Port Information: • IPPort="2050" is used by RollCall IPSharer (Configurable) / RollProxy (control) / Logserver32 / IQ Getaway • IPPort="2051" is used as a secondary port used by RollCall IPSharer for when Ctrl RollProxy is also running on the same PC • IPPort="2052" is used by RollLog/RollProxy(Logging)/Logserver32 -Primary IP Port used by RollMap and other clients to read log data and write changes such us masking • IPPort="2053" is used by RollProxy (Logging) -Secondary IP Port used for when Log Proxy and RollLog are running on the same PC (also used by the Display Processor Service (Hard Coded) • IPPort="2054" is used by RollSNMP Server-side Log data port • IPPort="2056" is used by RollLog/Logserver32 -Secondary (no updates) IP Port used by RollSNMP to write log data to the server • IPPort="2057" is used by Logserver32 RollPipes DLL -Debug Port • IPPort="2060" is used by RollSNMP Service Manager to send debug Messages is also used by Thumbnail Server Service - Installed as part of RollMap (up to 2.5.0 RC2) hard coded • IPPort="2061" is used by Thumbnail Server Service - Installed as part of RollMap (2.5.0 RC3 and later) configurable