Image Evaluation

Image Evaluation. Guidelines for Image Analysis Chapter 1. Facility’s Id Correct marker Required anatomy Accurate projection/position No unwanted distortion Cortical Outlines sharp Collimation Radiation Protection IR size & alignment Correct IR system Density & penetration

Download Presentation

Image Evaluation

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Image Evaluation Guidelines for Image Analysis Chapter 1

  2. Facility’s Id • Correct marker • Required anatomy • Accurate projection/position • No unwanted distortion • Cortical Outlines sharp • Collimation • Radiation Protection • IR size & alignment • Correct IR system • Density & penetration • Image contrast • No preventable artifacts • Properly ordered • Requisition & Post-procedure

  3. Facility’s ID • Facility’s name • Patient’s name, age or birth date • Exam time and date • ID plate * outside collimated field * away from direction CR is angled * next to narrowest anatomical

  4. Marking Images • Within collimated field? • Best position? • Accurate *Screen film *Digital * Is Required anatomy present on image?

  5. Patient Obliquity & Extremity Flexion • Accurate position demonstrated • Imaginary line • Degree of extension

  6. Shape Distortion • CR • Elongation • Foreshortening • Joint spaces • Poor positioning * magnified structure

  7. Helpful Hints • Use a grid if part thickness is over 5 inches and over 70 kVp is used • Small to medium plaster cast • +5-7 kVp +50-60% mAs • Large plaster cast • +8-10 kVp + 100% mAs • Fiberglass cast • +3-4 kVp + 25-30% mAs

  8. Detail Sharpness • Small focal spot • Unwanted motion • No magnification • Detail screen • Poor screen film contact • If CR is used; small possible IR

  9. Collimation • All four sides • Within ½ inch of skinline • To specific anatomy on torso • All required anatomy visible

  10. Radiation Protection • Present • Accurate for male and female • Tight collimation • Anatomical artifacts • Personnel protected • * IR positioned CW or LW properly

  11. Body Habitus • CW or LW • Smallest IR, multiple positions • Aligned in same direction • Correct IR system

  12. Density & Penetration • Optimal density • Overexposure & Underexposure • Changing penetration • Hypothetical conversation • Compensating filter or anode heel effect

  13. Guidelines for Digital • Correct diagnostic specifier for anatomy • For non-routine correct specifier • Center structure • Do not overlap collimation edges • Collimate tightly

  14. Image Contrast • Bony & soft tissue • Amount of scatter controlled

  15. Ordered Procedure • Postprocedure • Repeat or reject analysis