1 / 17

Single Molecule Fluorescence from Organic Dyes in Thin Polymer Films

Single Molecule Fluorescence from Organic Dyes in Thin Polymer Films. Robin Smith and Carl Grossman, Swarthmore College March 5, 2003. Acknowledgements. Carl Grossman Swarthmore College François Treussart, Jean-François Roch, and Romain Alleaume

deanne
Download Presentation

Single Molecule Fluorescence from Organic Dyes in Thin Polymer Films

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Single Molecule Fluorescencefrom Organic Dyes in Thin Polymer Films Robin Smith and Carl Grossman, Swarthmore College March 5, 2003

  2. Acknowledgements Carl Grossman Swarthmore College François Treussart, Jean-François Roch, and Romain Alleaume Laboratoire de Photonique Quantique et Moléculaire, Ecole Normale Supérieure de Cachan, France

  3. General Outline SMF Sample Fabrication Scanning Confocal Microscopy Photostability Photon Antibunching Single Molecule Emission Spectra Spectral Diffusion Photon Echo Measurements Dephasing Time

  4. Scanning Confocal Microscopy

  5. Photostability Photobleaching Blinking of fluorescence intensity versus time Dependence on excitation intensity (~2kW/cm2)

  6. Photon Antibunching The coincidence count histogram is normalized to give the photon-pair correlation function . Since two fluorescence photons cannot be detected within an arbitrarily short time interval, this antibunching in the fluorescence of the emitter at is due to the finite radiative lifetime of the molecular dipole and proof that single molecule emission has been observed.

  7. Single Molecule Correlation Function Data for R-101

  8. Time Intensity Plot

  9. Single MoleculeEmission Spectra Integration Time Scale Fluorescence Lifetime

  10. Dephasing Time Calculation Peak fit to Lorentzian lineshape function Based on classical model of electric dipole radiation Extract central and FWHM frequencies Calculate damping coefficient, the reciprocal of the dephasing time

  11. Spectral Diffusion Fluorescence peak wavelength varies between 590 and 610 nm Broader spectrum at shorter wavelengths gives shorter dephasing times

  12. Photon Echo Measurements Ultrafast optical dephasing (photon echo) measurements were performed on thin films of Nile Blue, Disperse Red, and Rhodamine-640 dyes. The experimental technique uses two-beam, time-delayed degenerate four wave mixing (DFWM) with incoherent light.

  13. PhotonEcho ExperimentSetup

  14. Peak Shift vs Temperature

  15. Dephasing Time Peak shift is twice the depasing time (T. Kobayashi, A. Terasaki, T. Hattori, and K. Kurokawa, Applied Physics B, 47, 107 (1988).) SMF gives dephasing times on the order of 4.7 fs at room temperature. Photon echo gives dephasing times approaching under 10 fs for extrapolation to room temperature,at which temperature peak shifts can no longer be resolved and interference fringes must be used for dephasing time determination.

  16. Conclusions Dephasing times for single molecule and photon echo measurements are likely to agree Spectral diffusion in SMF spectra exists

  17. Summary SMF Sample Fabrication Scanning Confocal Microscopy Photostability Photon Antibunching Single Molecule Emission Spectra Spectral Diffusion Dephasing Measurements

More Related