170 likes | 269 Views
Sentry 8501. High Efficiency Radiation Monitor. System Features. Microprocessor Controlled Uses Windows XP Touch Screen LCD Display Multi-channel Analyzer Broadband Internet Card High Resolution Digital Camera 2” x 2” NaI Detector(s) NEMA enclosure Strobe & Audio Alarm.
E N D
Sentry 8501 High Efficiency Radiation Monitor
System Features • Microprocessor Controlled • Uses Windows XP • Touch Screen LCD Display • Multi-channel Analyzer • Broadband Internet Card • High Resolution Digital Camera • 2” x 2” NaI Detector(s) • NEMA enclosure • Strobe & Audio Alarm
User Flexibility • Detector(s), up to 250 feet from monitor • Accommodates up to 9 detectors & cameras • Alarm threshold can be user defined • Alarm details stored on monitor’s hard drive • Optional notice to remote(s) • Photo of event – 1-9 images • Isotope ID plus MCA spectrum • Optional supervisor intervention to reset • Monitor to include or exclude medical isotopes
Monitor Mode Screen • Display counts above average background • Or can be in “Sleeping Watchdog” Mode
Upon Alarm Activation • Strobe & Audio alarms activate • Counts exceeding background noted on the screen, in red • Date & time is recorded • Picture(s) is taken of the event • Isotope spectrum is analyzed • Isotope ID is made • Detector location is noted • All data & pictures are stored on the HD • Optional Alarm alert(s) are forwarded
Password Protected Enter Password for System Set-Up View Event Log Reset System System Power Off
EVENT – last event at the top • DATE – date of event • TIME – to the second • COUNTS – above alarm threshold • LIMIT – threshold setting • ISOTOPE – nuclide ID • EVENT LOCATION – detector ID • CAMERA – if active, photo exist Tap event line for more details
Design Criteria • Operates without intervention • Functional in high radiation environments • High speed capture of event • Remote event notification • Nuclide identification • Photographic documentation of events • Optional exclusion of medical isotopes • Retained documentation of events • Automated field calibration checks
Sentry 8501 Specifications • Indicated Use: Gamma detection • Detector: 2.0” diam. X 2.0” thick, NaI(Tl) crystal • Detection Range: 35 keV – 3.0 MeV • Sensitivity: Typical, 15 cps/uR/hr 137-Cs gamma • Sampling Rate: 1 millisecond • Count Refresh Rate: 1 second • Isotope ID Sampling Rate: 2 seconds • Operating System: Windows XP • Monitor Display: 8” VGA TFT w/ touch screen • Display Resolution: 640 x 480 native, supports 1280 x 1024 • Nuclide ID: with 256 Multi-Channel Analyzers • Nuclide ID Range: 35 – 3000 keV • Nuclide Library: up to 99 gamma isotopes • Dimensions: 16” high, 11” wide, 8” deep; weight = 14 lbs • Power Requirements: 110 VAC / 500 Watts • Camera: high resolution digital
Sentry 8501 High Efficiency Radiation Monitor