An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Issue 4b Compliance location at Contra Costa Canal at Pumping Plant #1 -Proposed Solution - Richard A. Denton Water Resources Manager Contra Costa Water District

  2. Location of Sources of Degradation Holland Tract EC meter Local Seepage Source Contra Costa Canal Pumping Plant #1 Local Drainage Source

  3. CCWD Reduced Pumping Helped with 250 Compliance in Nov. 1999 Pumping Plant #1 Holland Tract Chlorides (mg/L)

  4. Reduced CCWD Pumping Helped with 150 Compliance in Dec. 2004 Holland Tract Chlorides (mg/L) 150 mg/L Pumping Plant #1

  5. Historical data show degradation due to seepage and local drainage Pumping Plant #1 Chlorides (mg/L) All Data 1983-2003 All Pumping Rates

  6. Pumping 30 cfs eliminates most effects 250 mg/L Pumping Plant #1 Chlorides (mg/L) 150 Pumping > 30 cfs

  7. Use cutoff between 30 cfs and 60 cfs 250 mg/L Pumping Plant #1 Chlorides (mg/L) 150 Pumping > 60 cfs

  8. Use Holland Tract to Determine Control Compliance: Beyond SWP and CVP Control Out of Compliance 250 Compliance: Pumping Plant #1 chlorides less than 250 mg/L 0.94 EC

  9. Location of Sources of Degradation Holland Tract EC meter Local Seepage Source Contra Costa Canal Pumping Plant #1 Local Drainage Source

  10. Proposed Modification: 250 M&I Objective • If CCWD diverting more than 20 cubic feet per second (cfs) at Pumping Plant #1 (3-day running average) and 250 mg/L chloride objective not met, M&I chloride objective considered exceeded • If CCWD diverting less than 20 cfs at Pumping Plant #1 (3-day average) and250 mg/L chloride not met, then: • Check Holland electrical conductivity (EC) from 3 days previously • If Holland EC greater than 0.94 mS/cm, M&I objective considered exceeded • If Holland EC equal to or less than 0.94 mS/cm, situation beyond control of DWR and USBR, and M&I objective not exceeded

  11. Proposed Modification: 150 M&I Objective • Similarly, if CCWD diverting more than 20 cfs at PP#1 (3-day average) and daily chloride at PP#1 is above150 mg/L, day does not count toward 150 mg/L objective • If CCWD diverting less than 20 cfs at PP#1 (3-day average) and chlorides above150 mg/L chloride, then: • Check Holland electrical conductivity (EC) from 3 days previously • If Holland EC greater than 0.56 mS/cm, that day does not count toward 150 mg/L M&I objective • If Holland EC is equal to or less than 0.56 mS/cm, situation is beyond control of DWR and USBR, and day counts toward meeting 150 mg/L objective

  12. Summary of CCWD Comments • Compliance location must remain at Pumping Plant #1 to ensure water diverted by CCWD is at or better than 150 mg/L and 250 mg/L M&I chloride objectives • Two major projects are currently well underway to eliminate effect of the two primary sources of degradation in Rock Slough and unlined section of Contra Costa Canal • If Pumping Plant #1 diversions less than 30-60 cfs (3-day average), M&I chloride objectives should not be considered exceeded at Pumping Plant #1 provided electrical conductivity at Holland Tract is at or better than specific EC targets • 250 mg/L = 0.94 EC • 150 mg/L = 0.56 EC

  13. Even with Los Vaqueros, CCWD still uses Rock Slough for water quality and water supply