An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. FSRUG Feedwater Systems Reliability Users Group (Jan 2012) San Antonio, TX SGFP Minimum Flow Operations – Impact on Reliability Presenter: Art Washburn, P.E.

  2. FSRUG • ICE BREAKER

  3. FSRUG TOPICS • Two Rules to Get You Home • Minimum Flow Protection – WHAT and WHY? • Minimum Flow Operation - Problems • Minimum and Maximum Flow Rates • Minimum Flow Energy Levels • Calculate Recommended Minimum Flow Rate • Guide for Minimum Flow Operation of Pumps • Recirculation - Large vs. Small Eye Impeller Design • Predicted Performance Curve for Replacement Feedwater Pump • Recirculation – Affect on Part Flow Operation and Corrected by Computational Fluid Dynamics (CFD) Analysis • Common Discussions Between User and Pump Supplier • Using Minimum Flow Protection for Discharge Piping Overpressure Protection • Minimum Flow Protection – Why ? • Source References

  4. FSRUG Two Rules:

  5. FSRUG Two Rules: Rule #1 – Make Conservative Decisions

  6. FSRUG Two Rules: Rule #1 – Make Conservative Decisions Rule #2 – Maintain Design Control

  7. FSRUG Two Rules: Rule #1 – Make Conservative Decisions Rule #2 – Maintain Design Control Plant Priorities:

  8. FSRUG Two Rules: Rule #1 – Make Conservative Decisions Rule #2 – Maintain Design Control Plant Priorities: • Nuclear Safety

  9. FSRUG Two Rules: Rule #1 – Make Conservative Decisions Rule #2 – Maintain Design Control Plant Priorities: • Nuclear Safety • Legal Requirements

  10. FSRUG Two Rules: Rule #1 – Make Conservative Decisions Rule #2 – Maintain Design Control Plant Priorities: • Nuclear Safety • Legal Requirements • Efficiency

  11. Minimum Flow Protection – WHAT and WHY? FSRUG • Assure Shutoff Head (zero flow) Operation Does Not Occur to Protect Pump from Catastrophic Damage • Extreme Minimum Flow (Unacceptable Temperature Rise) • Excessive Vibration (Damaging to Equipment) • Minimum Flow Path Recirculation Back to Pump Suction to a Large Volume Tank (Deaerator, Condenser) • Minimum Flow Controlled by Valve, Orifice Assembly • Main System Pump Suction Flow Velocity (8-10 FPS) • Main System Pump Discharge Flow Velocity (18-20 FPS) • Minimum Flow Piping Velocity (25-30 FPS)

  12. Minimum Flow Operation – Problems FSRUG • Pump Oversized for Application • Inlet Eye Diameter (too large, not optimum) • Head per Stage excessively high (OEM Pumps from 1970s) • Operating Strategy Changes since original Plant Specification • Minimum Flow Rate (thermal protection vs. continuous minimum flow rate)

  13. Minimum and Maximum Flow Rates FSRUG Recommended flow rate ranges for minimum and maximum, continuous and short-term, operation. From Gülich, Centrifugal Pumps. Specific Speed, nsns = (n x Q1/2)/(H3/4) nq = ns x 0.01936 Suction Specific Speed, nssnss = (n x Q1/2)/(NPSHR3/4)

  14. Minimum and Maximum Flow Rates FSRUG

  15. Minimum and Maximum Flow Rates FSRUG

  16. Minimum and Maximum Flow Rates FSRUG Ref. ISO/CD 10816-7:2004(E)

  17. FSRUG Minimum Flow Energy Levels The following criteria has an effect on determining minimum flow rates: • Specific Speed (Ns) • Suction Specific Speed (Nss) • Energy Level • Vibration / Pulsation Requirements • Service • Hours of Operation • Pumpage • Temperature Rise – Vapour Pressure • Ratio NPSHA to NPSHR • Impeller Material • Impeller Design • Lip Clearance • Normal Duty Energy Level Pumps

  18. FSRUG Minimum Flow Energy Levels • "Normal Duty" Energy Level for Pumps • "Heavy Duty" • "High Energy" (API-610 - greater than 650 FT/STAGE and greater than 350 HP/STAGE)

  19. Calculate Recommended Minimum Flow Rate FSRUG SGFP – Sulzer 16 x 18 x 17 CD 1 Stage, 5200 RPM

  20. Figure 1 - Guide for Minimum Flow Operation of Pumps FSRUG

  21. Application Notes for Figure 1 FSRUG • The minimum flow values given are for continuous operation. Continuous operation is considered as more than 2-hours in any 24 hours of operation. • For intermittent operation, reduce the minimum flow values given by 10 percentage points. • The minimum flow values given are for suction specific speeds (Nss) less than 10,000. Above 10,000 Nss, then increase the values given by 2 percentage points for each 1,000 Nss greater than 10,000 Nss. • The minimum flow values are percentages of flow at Best Efficiency Point (B.E.P.) flow taken as 100%. • Specific Speed (Ns), Suction Specific Speed (Nss) and head per stage are determined at best efficiency point for the actual impeller trim performance. • For multistage pumps, use the Specific Speed (Ns), Suction Specific Speed (Nss), and the head per stage of the first stage impeller. • Specific Speed (Ns) and Suction Specific Speed (Nss) for double suction impellers are based on 50% of total flow.

  22. Calculate Recommended Minimum Flow Rate FSRUG SGFP – Sulzer 16 x 18 x 17 CD 1 Stage n = 5,200 RPM Q = 20,000 GPM @ BEP H = 2,300 FT/STAGE @ BEP NPSHR = 190 FT @ BEP ns = (n x Q1/2)/(H3/4) = (5200 x 20,0001/2)/(23003/4) = 2200 nss = (n x Q1/2)/(NPSHR3/4) = (5200 x 10,0001/2)/(1903/4) = 10,000 Min Flow = (0.60)(20,000) = 12,000 GPM

  23. Recirculation – Large Vs Small Eye Impeller Design FSRUG • Suction and Discharge Recirculation occurs at off peak (low flow) conditions. • The turbulent mixing action due to suction or discharge re-circulation leads to surging, pulsations, vibration, and noise

  24. Recirculation – Large Vs Small Eye Impeller Design FSRUG • Recirculation & Cavitation Damage • Large Eye = High Nss (suction specific speed)

  25. FSRUG Predicted Performance Curve for Replacement Feedwater Pump

  26. Recirculation – Large Vs Small Eye Impeller Design FSRUG Large eye NPSH performance test, notice the unstable high vibration at low flows. Eye Diameter = 7.38” (Large Eye) NSS = 17,000 6 x 10 x 14 CD

  27. Recirculation – Large Vs Small Eye Impeller Design FSRUG

  28. Recirculation – Large Vs Small Eye Impeller Design; Pump Vibration Levels FSRUG Permissible Vibration Limit ‘Large eye’ 4 vanes 96.4% Max.Dia. Vibration Level Veff (10-10-1000 Hz) / mm.s-1 (RMS) ‘Small eye’ 5 vanes 96.4% Max.Dia. Slide shows the difference between the two impeller designs in vibration levels. Flow Rate / gal (UK)/Min

  29. Recirculation – Large Vs Small Eye Impeller Design FSRUG Stall ring design is a temporary fix, to have the same influence as the small eye design on the pump suction performance, note the B.E.P will not be repositioned with this fix

  30. Recirculation – Large Vs Small Eye Impeller Design FSRUG • Equation for Optimizing Eye Diameter: • Eye Diameter (I.D.) = • [(51.27)(Q/N)^0.666 + (Dia Shaft)^2]^0.5

  31. Recirculation – Affect on Part Flow Operation and Corrected by Computational Fluid Dynamics (CFD) Analysis FSRUG Closed Impellers typically are lift set based on total mechanical endplay, and thermal growth. The location of the impeller to volute cutwater on discharge and suction can affect suction and discharge recirculation.

  32. Recirculation – Affect on Part Flow Operation and Corrected by Computational Fluid Dynamics (CFD) Analysis FSRUG

  33. Recirculation – Affect on Part Flow Operation and Corrected by Computational Fluid Dynamics (CFD) Analysis FSRUG

  34. Recirculation – Affect on Part Flow Operation and Corrected by Computational Fluid Dynamics (CFD) Analysis FSRUG

  35. FSRUG Common Discussions between Utility and Pump Supplier for Replacement Pump or Repaired Pump: • Continuous Minimum Flow Required by Specification vs. Existing Limitations of Minimum Flow Piping Size • Vibration Limits Required by Specification (recent limits are more stringent) • Demands to Guarantee Mechanical Performance (Vibration) on Test Stand and in Field

  36. FSRUG Using Minimum Flow Protection for Discharge Piping Overpressure Protection • Common on Heater Drain Pumps • Be Aware When Rerating as Part of EPU

  37. FSRUG Minimum Flow Protection – Why ? - Shutoff Head Operation

  38. FSRUG SOURCE REFERENCES: • Centrifugal Pumps: Design & Application, Lobanoff and Ross (practical application) • Centrifugal and Axial Flow Pumps, Stepanoff (theory) • Centrifugal Pumps, Gülich • Vertical Turbine, Mixed Flow & Propeller Pumps, Dicmus • Centrifugal Pump Handbook, Sulzer • Pump Handbook, Karassik • Centrifugal Pump Clinic, Karassik • Centrifugal Pumps Selection & Operation, Karassik • Centrifugal Pumps, Karassik