1 / 15

Direction-detection spectrometer concepts the CCAT

Direction-detection spectrometer concepts the CCAT. Matt Bradford + others 24 October 2006, in progress. 850 micron counts (stolen from A. Benson talk). Recall: modified IMF and star formation timescale included to reproduce 850 micron counts.

diamond
Download Presentation

Direction-detection spectrometer concepts the CCAT

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Direction-detection spectrometer concepts the CCAT Matt Bradford + others 24 October 2006, in progress

  2. 850 micron counts (stolen from A. Benson talk) Recall: modified IMF and star formation timescale included to reproduce 850 micron counts Matt Bradford

  3. Models provide approach to CCAT population z distribution: Apply to C+ 350 um window 13% of sources 350 & 450 microns window are likely to access 31% of the 850 micron population in C+ 450 um window: 21% of sources Redshift Distribution from GALFORM model -- similar to Chapman

  4. C+ 158 microns redshifted for CCAT spectrograph Recall: a 1 mJy 850 micron source is a ULIRG, independent of redshift CCAT spectroscopic sensitivities: 5 sig, 1h W/m2: 1.8e-19 (350) 1.2e-19 (450)

  5. Options for far-IR through mm spectrometers • Grating spectrometer is the best choice for point sources • 1st order  octave of instantaneous bandwidth • Good efficiency • But only moderate resolution • Fabry-Perot naturally accommodates spectral mapping • But scanning time results in sensitivity penalty, esp for searching • Fourier transform spectrometer (FTS) couples the full band to a single detector • Sensitivity penalty • Heterodyne receivers provide the highest spectral resolution • But suffer from quantum noise NEPQN ~ hn [dn]1/2 vs. NEPBG ~ hn [n (n+1) dn]1/2 • Also offer limited bandwidth: • 10 GHz IF bandwidth at 1 THz gives n / Dn ~ 100 Matt Bradford

  6. C+ 158 microns redshifted for CCAT spectrograph Based on 1 hour sensitivities 1 mJy population is likely to be candidates for spectroscopy Source densities: 1 mJy (850) source densities: 1.2e4 per square degree -> means one per 65-100 (@ 450,350) CCAT beams Wideband spectroscopic follow-up

  7. Examples of submillimeter-wave broadband systems: ZEUS for the JCMT / APEX Entrance slit Grating BP Filter Wheel M4 LP Filter 2 Detector Array M6 M5: Primary M2 M3 LP Filter 1 4He Cold Finger Entrance Beam f/12 3He Dual Stage Refrigerator Scatter Filter M1 4He Cryostat Cornell -- Stacey et al. 350, 450 mm windows w/ R~1000-1500 Matt Bradford

  8. A new R~1000 echelle spectrometer for CCATAMULE -- Atacama MUltiband Longslit Echelle Design: Grating 816 micron pitch Assuming 128 spectral element array -- e.g. 0.86 mm pixels -- f/2.5 spectrometer, slightly oversampled Angular deviation off the grating 18 deg total. collimator must be oversized by 12 cm ! --> 30 cm diameter collimator --> grating 30 cm by 40 cm, to accommodate spatial throughput Matt Bradford

  9. AMULE is large • So grating and collimator large fraction of 1 meter in all dimensions -- 1.5-2 times larger than ZEUS • Reimaging optics size will depend on the size of the slit, but also grows relative to ZEUS: • --scales as telescope f# x #of beams: Relative to ZEUS, AMULE will have 8/12 x 128/32 = 2.7 times larger reimaging optics. • Requires 35 cm (+ overhead) window if reimaged from telescope focus inside cryostat (but can be shaped like a slit) • Optics envelope inside cryostat approaching 1 meter in all dimensions. • Large but doable. 40 cm 30 cm 35 cm Matt Bradford

  10. How about an imaging Fabry-Perot(BIG Imaging Fabry-Perot Interferometer (BIFI)) SPIFI demonstrates concept, at JCMT & the South Pole 5x5 spatial array, two scanning FPs provide R up to 10,000 at 200-500 microns 60 mK ADR-cooled focal plane Matt Bradford

  11. ALMA Primary beam at 810 GHz And Herschel under-resolves it Herschel beam at 810 GHz 16x16 array on CCAT ALMA will resolve out extended emission in nearby galaxies CO 3-2 M. Dumke et al. 2001, CO 7-6 Bradford et al. 2003, Matt Bradford

  12. How about an imaging Fabry-Perot(BIG Imaging Fabry-Perot Interferometer (BIFI)) BIFI will be much larger than SPIFI due to the large throughput Limitation is beam divergence in the high-res FP. Dcol ~ 1.5 l (R x nbeams)1/2 3 min x 3 min field Field size (1-D) driven by 20 cm beam Order-sorter also requires collimated 2.2cm (or slow) beam 1-D field size for 20 cm beam High-order FP spacing (mm) w/ F=60 Matt Bradford

  13. BIFI will be much larger than SPIFI due to the huge throughput 8 x 20 cm = 160 cm collimator focus Faster final focal ratio (2-3) to accommodate large array Full field at f/8: 20 cm window! Array is as large as 10 cm Etalon spacing is modest: few cm even for 650 mm Collimated beam + overheads: 25 cm dia(and etalon must be near pupil) Factor of two in all dimensions of the optical train Matt Bradford

  14. WaFIRS is an ideal broad-band point source architecture. -- possibility for multi-object spectroscopy Currently 4-5 cm delta z per module But could be smaller, far from limits: -- stiffness of plates -- detector illumination -- feed (f lambda from the telescope)

  15. WaFIRS is an ideal broad-band point source architecture. -- possibility for multi-object spectroscopy 50 cm for > 10 modules

More Related