440 likes | 878 Views
12a. Cooling Systems; Refrigerants; Condenser/Evaporator Compressive; Absorption; Evaporative; Chillers; Heat Sinks. Chapter 4 (Toa). Cooling Systems. HVAC 11a CNST 305 Environmental Systems 1 Dr. Berryman. Air Conditioning. Definition
E N D
12a Cooling Systems; Refrigerants; Condenser/Evaporator Compressive; Absorption; Evaporative; Chillers; Heat Sinks Chapter 4 (Toa) Cooling Systems HVAC 11a CNST 305 Environmental Systems 1 Dr. Berryman
Air Conditioning • Definition • Process of treating air in an internal environment to establish and maintain required standard of temperature, humidity, cleanliness, and motion.
Heat Transport Systems • Air • Water • Steam A/C Systems can use one…or a combination of transports
Components - A/C System • Minimum Components
Cooling Equipment • Common refrigeration systems Used for different applications and climates
Compression Cycle • Fundamentals • Refrigerant characteristic • Boiling Point • Condensing Point • Saturation Point All three have the same numerical value
Refrigerants • Refrigerant: R-123, R-22, R12 • Water: R-718 • Carbon Dioxide: R-744 • Ammonia: R-717
212°F [100°C] temperature pressure 14.7 psia [0.10MPa] Boiling Point of Water
R-22 boils at -41.4°F [-40.8°C] Refrigerant R-22
121.5°F [49.7°C] temperature 41.2°F [5.1°C] 85 psia [0.59 MPa] 280 psia [1.93 MPa] pressure Boiling Point of R-22
Effects of Pressure • Increase in pressure on a refrigerant • Results • Increased boiling, condensing, and saturation points • Decrease in pressure on a refrigerant • Increased boiling, condensing, and saturation points
Refrigeration Cycle airflow liquid refrigerant(R-22) collects refrigerant vapor -41.4°F [-40.8°C]
Refrigeration Cycle ? Closing the Cycle
expansion device evaporator condenser compressor Refrigeration Cycle
Evaporator A mixture of liquid and vapor refrigerant B refrigerant vapor air
Compressor B C low-pressure refrigerant vapor from evaporator high-pressure refrigerant vapor to condenser
Condenser C refrigerant vapor D liquid refrigerant outdoor air
Expansion Device A mixture of liquid and vapor refrigerant D liquid refrigerant
Basic Refrigeration System C discharge line condenser liquid line B compressor Direct expansion device (DX) A suction line D evaporator
SEER vs HSPF • SEER • Seasonal Energy Efficiency Ratio • Index of MPG for a/c • Number of BTU’s removed by 1 watt of electricity • Rating range from 8 – 14 SEER • Water cooled condensers can achieve higher (system w/ water tower) • HSPF for heat pumps • Heating Seasonal Performance Factor • BTU per watt
Heat Pump Reversible Refrigeration System
COP • Coefficient of Performance (1-5) • Commercial Heating efficiency index • COP of 1 = 3,400 BTU/Kw • Strip heaters, toasters, water heaters, etc. • COP 2 • 3,400 BH electrical - 3,400 OA environment • TOTAL 6,800 BH • COP 3 • 3,400 BH electrical – 6,800 OA environment • TOTAL 10,200 BH • HSPF -Heating Seasonal Performance Factor • BTU per watt – Heating index for Residential • COP 2 = HSPF 6.8
Air Source Heat Pump COP Heat Pump COP changes w/ source temperature
Large A/C Equipment Air Handler Chiller Cooling Tower
Air Handler Fan/Coil Unit
Chiller - Compression • Reciprocating • Cylinder displacement • Scroll • Scroll displacement • Rotary Helical • Screw - type • Centrifugal • impellers Cut Away – Rotary Helical Chiller
Water Towers • Central Plant • 500 – 30,000 GPM
Chillers - Absorption condenser generator evaporator absorber
Refrigerant • Distilled water • Stable • Nontoxic • Low cost • Readily available • Environmentally friendly • High latent heat of vaporization
Boiling Point of Water 115°F [46.1°C] temperature 45°F [7.2°C] 1.5 psia [10.34 kPa] 0.15 psia [1.034 kPa] pressure
Absorbent • Lithium Bromide (LiBr) • High affinity for water (refrigerant) • In solution, higher boiling point than water • Nontoxic
Absorption Cycle Cooling Tower steam or hot water Boiler condenser High Pressure cooling water generator evaporator Air Handler chilled water Low Pressure heat exchanger absorber Cooling Tower
Absorber refrigerant vapor absorber 100°F 0,15 psi intermediate solution absorber spray pump dilute solution cooling water concentrated solution From Cooling Tower To generator
Generator steam or hot water refrigerant vapor generator concentrated solution dilute solution
Condenser refrigerant vapor condenser 115°F 1.5 psi cooling water liquid refrigerant
Evaporator refrigerant vapor 45°F 0,15 psi chilled water evaporator Air Handler liquid refrigerant absorber evaporator spray pump
Expansion Device liquid refrigerant evaporator expansion device
Heat Exchanger concentrated solution precools the concentrated solution heat exchanger dilute solution generator pump