LithoWorks PEB. PEB and CD analysis of two plates. August 14, 2003 Thermal analysis of two PEB plates: 093-08_peb_bake7.csv 093-08_peb_bake8.csv. Summary. These are preliminary results The first half of this analysis addresses PEB thermal analysis for PEB’s 7 & 8

Download Presentation

PEB and CD analysis of two plates

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. LithoWorks PEB PEB and CD analysis of two plates August 14, 2003 Thermal analysis of two PEB plates: 093-08_peb_bake7.csv 093-08_peb_bake8.csv

  2. Summary • These are preliminary results • The first half of this analysis addresses PEB thermal analysis for PEB’s 7 & 8 • Investigates Temperature cycle • Energy installed into the wafer (Temp * Time) • Variation in energy installed • Temperature over time contour plots • The second half of the analysis examines two Nanometrics OCD data sets • Fixed focus analysis of wafers 12,16 • Wafer 12 = PEB 8 • Wafer 16 = PEB 7 • The data has been modeled for across wafer variation • Residuals to the wafer model illustrate the anticipated, non-PEB influenced performance • Statement based upon expected whole-wafer variation of PEB temperature • The last slide touches on Wafer 13 & 17 • These are FEM arrays and warrant further study. LithoWorks PEB - Two plate study

  3. Initial Observations • PEB Thermal Analysis • The Bake cycle was examined as a function of: • Time-Temperature curve • Time-temp variations across wafer. • Total energy (integrated time * temperature) delivered to the wafer • Energy variation across wafer due to non-uniform heating. • PEB 7 is more uniform than PEB 8 • Not observed in the temperature or the total energy delivered • Can be seen in the plots of temperature variation from wafer mean over time and in the Energy Variation plots. • Neither bake plate is allowing enough time for the bake temperature to achieve steady state. • See slides 26 to 28 • Feature Response • Note: The On-Wafer sensor orientation has not been corrected or adjusted for this analysis. LithoWorks PEB - Two plate study

  4. Feature Response and Correlation • Feature Response • Note: The On-Wafer sensor orientation has not been corrected or adjusted for this analysis. • Examined wafers 12 (PEB 8) and wafer 16 (PEB 7) • Each feature’s variation was modeled for whole-wafer variations • Wafer-model should correlate to PEB energy variations • Residuals to wafer model should be approximate equal in response • if both wafers were exposed on same scanner • Residuals to wafer model should show exposure tool performance. • MSE Behavior • Differs significantly for Vertical (group 1) and Horizontal (group 2) features. • May be the result of scanner slit vs scan sensitivity of feature edges. • May also be from metrology tool algorithm. • There is no strong and obvious visual correlation of PEB energy and feature response. • There is a suggestion of PEB energy variation and SWA • Further studies • More thought must be given to these correlations. • FEM wafers need to be studied. LithoWorks PEB - Two plate study

  5. PEB #7 LithoWorks PEB - Two plate study

  6. PEB #7 overview • Left graphic • Details location of sensor points • Right graphic • Summary of rise/fall times vs temperature LithoWorks PEB - Two plate study

  7. Sensor variation from wafer mean • Each site contains a plot of delta-temp versus time • Area • product of (degrees * seconds), summed over all sites. This is proportional to the energy entered into the wafer during the bake. • Area Variance • Energy variation across the wafer • Summed deg-sec’s over all sites reporting total variation from mean-temperature over time. LithoWorks PEB - Two plate study

  8. Corresponding points on the graph • Moving the mouse to a point on the temp-time curve will highlight the corresponding points on the delta-temp wafer plot (50.1 sec, 113 C) LithoWorks PEB - Two plate study

  9. On-Wafer thermal loading? Area of sensor packet • Notice how the 7 wafer-center sites are the first to rise in temperature. • Note also the two sites located over the On-Wafer sensor packed lag in heading and also lag in cooling. This area also does not reach uniformity until the end of the heading cycle. • This is most probably due to the thermal-mass loading of the sensor packet. • The red-dot on each plot marks the same relative point on each site. LithoWorks PEB - Two plate study

  10. PEB 7; Thermal Energy Delivered • Plot of thermal area (deg-sec) across wafer. • Notice that there is a range of 168,714 deg-sec with the upper left of the wafer receiving the most energy • Thermal-package sensor area is relatively cool • No activation threshold was set for this plot thermal sensor area LithoWorks PEB - Two plate study

  11. PEB 7; Thermal Energy Delivered • Plot of area (deg-sec) integrated over time • Notice that there is a range of 168,174 deg-sec with the upper left of the wafer receiving the most energy LithoWorks PEB - Two plate study

  12. PEB 7: Thermal Energy Variance across wafer • Variation in energy (integrated temperature*time) delivered • Variation is greatest at wafer’s upper left corner, least in center & right. LithoWorks PEB - Two plate study

  13. Thermal Energy Variance Across Wafer - Contour LithoWorks PEB - Two plate study

  14. PEB 8 Data

  15. Plate PEB 8, Bake Curve • Top: PEB 8 • Bottom: PEB 7 • Curves appear very similar in shape. LithoWorks PEB - Two plate study

  16. PEB 8; Delta-Temperature Response • Same point is marked on the time-temp curve. • Distribution in upper left of wafer is now very uniform. (50.1 sec , 113 C) LithoWorks PEB - Two plate study

  17. Comparison PEB 8 vs PEB 7 • Time-Temp Area Differences • PEB 8 • has a higher energy area. • Exhibits greater excursion range and variation across the plate. PEB 8 PEB 7 LithoWorks PEB - Two plate study

  18. Comparison: Delta temperature with time • PEB 8 exhibits more variation at the bottom of the wafer. PEB 8 PEB 7 LithoWorks PEB - Two plate study

  19. PEB 8; Thermal energy delivered LithoWorks PEB - Two plate study

  20. Thermal Energy Delivered – Bake 8 Contour LithoWorks PEB - Two plate study

  21. PEB 8 Thermal Energy LithoWorks PEB - Two plate study

  22. PEB 8; Thermal Energy Variation LithoWorks PEB - Two plate study

  23. Comparison: Thermal Energy Delivered – PEB 8/ PEB 7 • Both wafers as plotted on the same scale. • More thermal energy delivered to PEB 7 PEB 8 PEB 7 LithoWorks PEB - Two plate study

  24. Thermal Energy Variation – Bake 8 Contour • Energy delivered as a delta from the wafer average temperature. • Energy = Sum((Temperature-Activation Temp.) * DeltaTime) • DeltaTime = time interval of sample LithoWorks PEB - Two plate study

  25. PEB 8: Greatest variation in thermal energy LithoWorks PEB - Two plate study

  26. Comparison: Thermal Energy Variation – PEB 8/ PEB 7 • Scales vary but characteristic is same • PEB 7 has has significantly better energy uniformity PEB 8 PEB 7 LithoWorks PEB - Two plate study

  27. Comparison energy variation statistics • PEB 8 exhibits • A greater mean temperature, range and variance of temperature than PEB 7 PEB 8 PEB 7 LithoWorks PEB - Two plate study

  28. PEB 8/ PEB 7; thermal variation • PEB 8 and 7 variations plotted to the same scale. PEB 8 PEB 7 LithoWorks PEB - Two plate study

  29. Thermal range study Bake8 • Temperature range about the average temperature of the wafer at each time-slice. • The cycled-temperature rose a total of 98.07 degrees. • Steady state uniformity is 0.18 degree across wafer. • Notice that the wafer at 121 degrees (max. temp at 134 sec.) did not reach steady-state uniformity. LithoWorks PEB - Two plate study

  30. Thermal range study Bake7 • Same study with PEB 7 • This study shows a red square at each transition start/stop point on the curve. LithoWorks PEB - Two plate study

  31. Range Uniformity Summary • Plots exhibit the thermal range across the wafer at each time-slice • Both plates exhibit the same steady-state thermal resolution. • Thermal range and maximum temperatures differs by approximately one degree • Neither plate reaches steady state while at the maximum temperature. • Bake 8 has • greater across-wafer variations (9.6 v 7.0 degrees) • Greater range at the final temperature (0.9 v 0.6 degree) • Smoother cooling curves than 7 • Near identical rise/cool thermal slopes and time at the maximum temperature compared with Bake 7 • Conclusion: Bake 8 has more thermal variation across the wafer. Bake 8 Bake 7 Bake 8 LithoWorks PEB - Two plate study

  32. Thermal Uniformity at any point in time • Generate single or matrix graphics of all of the plots. • A “movie” video will also be added to allow you to watch wafer heating. LithoWorks PEB - Two plate study

  33. PEB 8 – Steady State Temperature LithoWorks PEB - Two plate study

  34. PEB 8 Steady State Temp LithoWorks PEB - Two plate study

  35. Thermal changes during the up-ramp LithoWorks PEB - Two plate study

  36. CD data review

  37. Data Setup and Organization Wafer 12: processed on PEB plate 8, const. exp/focus 18.5/0 Wafer 13: processed on PEB plate 8, FEM 18.5/0 +- 0.5/0.05 Wafer 16: processed on PEB plate 7, const. exp/focus 18.5/0 Wafer 17: processed on PEB plate 7, FEM 18.5/0 +- 0.5/0.05 • The measurements are taken on a nominal 150:150 grating, • somewhat overexposed here (~140nm average linewidth). • All wafers have PAB step on plate 1, also attached. • For the PEB data, there are several measurements for each plate, each corresponding to a different orientation of the sensor wafer. • '3_oclock', for example, means that the wafer module is at the 3o'clock position relative to the cassette. • 1-2 o'clock is the position between 1 and 2, which appears to be 3/4 of a full rotation from the orientation of the process wafer when it's on the PEB plate-since OnWafer formats the data such that the module is situated at 3 o'clock, this means we just have to rotate the 1-2 data 180 degrees and should have the right orientation. • Within the Nanometrics data set, there are two "groups" of data for each wafer • group 1 corresponds to measurements made on gratings with lines of vertical orientation • group 2 corresponds to the horizontal orientation. LithoWorks PEB - Two plate study

  38. Wafers 13,15; Assumed Dose and Focus layout • Wafers 12 & 16 are fixed focus/dose LithoWorks PEB - Two plate study

  39. MSE behavior (12 & 16) • MSA can be used to determine the measurement quality • Variation is in fact a little better for the FEM wafers than the fixed exposure. • Probably due to the bi-modal distribution of the fixed-exposure data. Layout, all sites LithoWorks PEB - Two plate study

  40. MSE; Wafer 12 (PEB 8) • Horizontal and vertical features are responding differently to MSE LithoWorks PEB - Two plate study

  41. Wafer 12, TCD (fixed focus, Group #1) • Vertical Features All features LithoWorks PEB - Two plate study

  42. Wafer 12, TCD group 2 (Horizontal) • Field layout is shown on the left. LithoWorks PEB - Two plate study

  43. Wafer #12 –T3 (PR) Group 1 • Photoresist thickness behaves quite differently for vertical vs horizontal feature orientation. Group 2 LithoWorks PEB - Two plate study

  44. Wafer 12, BCD • Have about 3 nm of difference in mean values. • Range of values is the same to within 0.7 nm LithoWorks PEB - Two plate study

  45. Wafer #12, BCD Residuals to Wafer variation • Aberrations of scan or slit are influencing the CD variation • Left = vertical features so edges are influenced by the scan • Right = horizontal features so there is more slit influence. LithoWorks PEB - Two plate study

  46. Wafer 12; SWA LithoWorks PEB - Two plate study

  47. Wafer #12; SWA Residuals to wafer model • The horizontal line behavior (right) is very surprising. • Metrology Algorithm? LithoWorks PEB - Two plate study

  48. Wafer #12 model; BARC T2 • Good, repeatable to about 0.1 nm LithoWorks PEB - Two plate study

  49. Wafer #12; BARC residuals • Vertical features (#1) have characteristic ring. Ring is not as evident in the horizontal features on the left. • Scale on left is wider because of the difference in noise. LithoWorks PEB - Two plate study