1 / 5

VMware Certified Advanced Professional 6.5 - Data Center Virtualization Design Exam 3V0-624 study materials

Troytec.com study materials are highly customized as per the syllabus of VMware for 3V0-624 Certification exam. Getting VMware Certified Advanced Professional 6.5 - Data Center Virtualization Design Exam 2019 exam is possible only when you choose to opt for good study materials. The Troytec exam questions are well structured and you get them in easy to use formats, Practice software, Android and PDF file. Get more information visits it: https://www.troytec.com/exam/ 3V0-624-exams

Download Presentation

VMware Certified Advanced Professional 6.5 - Data Center Virtualization Design Exam 3V0-624 study materials

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 3V0-624 VMware Certified Advanced Professional 6.5 - Data Center Virtualization Design Exam Exam : 3V0-624 Demo Edition © 2017- 2018Troy Tec, LTD All Rights Reserved 1 http://www.troytec.com

  2. 3V0-624 QUESTION: 1 A company has requested assistance with a new cross-site failover design to support business-critical applications. A. It has two sites when are very well-connected, and latency is less than 5ms round trip. A. The customer requires that its applications be restarted even in the event of a total site failure. A. The applications must be kept online even when migrated during maintenance. A. Storage arrays at either site support both synchronous and asynchronous replication. Which two options are accurate application requirements for this scenario? (Choose two.) A. The design must ensure continuous application uptime even during a total site failure. B. The design must prioritize application availability. C. The design must ensure application recoverability at the second site. D. The applications are latency-sensitive. Answer: A, B QUESTION: 2 An organization's security policy requires a design where the ESXi hosts will be manageable only through vCenter Server. Which two security configurations will help meet this requirement? (Choose two) A. enable lockdown mode strict B. disable DCUI access C. enable lockdown mode normal D. disable shell access Answer: C, D QUESTION: 3 DRAG DROP A company would like to utilize its current infrastructure but wants to adopt virtualization to consolidate its environment. Currently, the infrastructure contains: A. server with 2 x 8 cores CPUs and 96G8 of memory A. backup LAN with a single physical switch A. production LAN A. sufficient datastore performance as determined by the storage team Match the existing infrastructure component to its appropriate concept. 2 http://www.troytec.com

  3. 3V0-624 Answer: Exhibit QUESTION: 4 DRAG DROP A company has requested assistance with a new cross-site failover design between two sites which will support business- critical applications. Latency between the sites is less than 5ms round-trip.The company requires: A. application must be restarted quickly in the event of a total site failure A. allow for planned migration during maintenance A. applications must be kept online even when migrated due to planned maintenance Drag each statement to its correct concept 3 http://www.troytec.com

  4. 3V0-624 Answer: Exhibit QUESTION: 5 A customer warns to virtualize an Oracle database with vSphere 6.5, but is concerned about its performance. Which three design elements will ensure optimum performance? (Choose three.) A. Share as much memory as possible with the balloon driver. B. Use VMXNET3 for the network adapter. C. Create affinity rules for the virtual machine to a single physical socket. D. Use VMware Paravirtual SCSI adapters for data and log vDisk. E. Enable Hyper-Threading 4 http://www.troytec.com

  5. 3V0-624 Answer: A, B, E 5 http://www.troytec.com

More Related