STATIM. http://piercers.com/statim-g4-announced/. BY: SANDRA GONZALEZ, JULIE MEDEIROS, MALVINA PREDOLIAK, & KIMBERLY BEDOLLA. History of the S tatim. 460 and 377 B.C. - Hippocrates uses boiling water for instruments 1700’s AD - Lazzaro Spallanzani experiments with bacteria
E N D
STATIM http://piercers.com/statim-g4-announced/ BY: SANDRA GONZALEZ, JULIE MEDEIROS, MALVINA PREDOLIAK, & KIMBERLY BEDOLLA
History of the Statim 460 and 377 B.C. - Hippocrates uses boiling water for instruments 1700’s AD - Lazzaro Spallanzani experiments with bacteria Bacteria died in heated environment www.galloimages.co.za
April 20, 1862 Louis Pasteur tests with heated liquids Pressurized containers are used Pasteurization is discovered Still used today noticulturaleshoy.blogspot.com
First Autoclave Charles Chamberland and Pasteur worked together Pasteurization is developed 1879 - first autoclave developed fr.wikipedia.org
What is autoclave? Pressure cooker Creates steam Usually takes time technologyinscience.blogspot.com
First Statim 1990 Statim developed in Pennsylvania Used for more than 20 years en.wikipedia.org
Several generations of Statim 2012 - latest STATIM G4 Internet connectivity www.dentalproductsreport.com
Efficiency of Autoclave • Compare four methods of sterilization: • Autoclaving • Carbon dioxide lasers • Chemical sterilization (with glutaraldehyde) • Glass-bead • Results: • Autoclaving and lasers: 100% sterilized • Glass bead sterilization: 90% sterilized • Chemical sterilization: 80% sterilized
Pre-sterilisation cleaning of re-usable instruments. • Effective cleaning of instruments is an essential part for reliable sterilisation. • Multiple techniques are used for instrument cleaning prior to sterlisation. • Many practices lack effective pre-cleaning procedures including PPE’s.
Statim Cassette Tray • Dimensions: • L 280mm x W 180mm x H 35mmL 11" x W 7" x H 1.5“ • Unwrapped: 2.2lbs. of solid metal instruments • Wrapped: 2.2lbs. of solid and hollow instruments statim.us
Statim Features: Wrapped: 10 mins. to sterilize Use for later Unwrapped: 3.5 mins. to sterilize For immediate use brnskll.com brnskll.com
Pre-Sterilization: Wrapped Instruments • Wear full PPE’s • Run through an ultrasonic or Miele • After ultrasonic, rinse under water and dry • Package instruments in sterilization pouch • Indicator strip in pouch • Date the pouch • Place on Statim tray www.delhidentist.in
Pre-Sterilization: Unwrapped Instruments • Wear full PPE’s. • Second run through an ultrasonic or Miele. • After ultrasonic, rinse under water and dry • Place on Statim tray in organized manner labanamedicalstore.com
Dental instrument and device sterilization and disinfection practices • 1,391 dentists in private practice • 68% used: • Autoclaves • Chemical Sterilants • Beads • 42% actually effective!
Autoclave performance and practitioner knowledge of autoclave use: A survey of selected UK practices. • 70% checked for effectiveness • Chemical Strips • Spore Tests
Operation of the STATIM • Place instruments in cassette
2. Close & insert cassette • Hinge tab hinge slot • Gently push cassette until it “clicks”. • Check LCD screen
Air-drying phase • 60 minutes • Instruments Sterile • Stop • Don’t stop
Opening the Cassette • Remove cassette • Hold cassette with thumbs facing inward • Press down on latch • Disengage hinge
Maintaining the STATIM • Clean cassette • Clean water reservoir filter • Clean reservoir • Clean exterior
Maintaining Fluid Levels • Water Level • Water Quality
STATIM vs. M9 & M11 Autoclave www.medsupplier.com www.scican.autoklaw.pl
What separates the statim from the autoclave? STATIM Cassette • STATIMS SPEED • IMMEDIATE STEAM GENERATION • DRYING TECHNOLOGY • CASSETTE SYSTEM • USES ONLY A SMALL AMOUNT OF WATER FOR EACH CYCLE • UNIT SIZE IS SMALLER (length,width,height) • A HIGH RESOLUTION 65K COLOR TOUCHSCREEN proclave.net High Resolution Touch Screen in Color www.medilexonline.com
Works Cited • Bagg J, Smith AJ, Hurrell D, McHugh S, Irvine G. Pre-Sterilisation cleaning of re-usable instruments in general dental practice: British Dental Journal [Internet]. 2007 [Cited 2013 November 01]; 202:E22 • Burke F, Coulter W, Cheng S, Palenik C. Autoclave performance and practitioner knowledge of autoclave use: A survey of selected UK practices. Quintessence International 1998 Apr; 29(4): p.231-238 • Darby ML, Walsh MM. Dental Hygiene Theory and Practice. 3rd ed. Dolan JJ, editor. St. Louis (MO): Saunders Elseivier; 2010. p.79-99 • Gurevich R, Dubin R, Cunha B. Dental instrument and device sterilization and disinfection practices. J Hosp Infect [Internet]. 1996 Apr [cited 2013 November 03];32 (4):296-304. • Statim2000/ 5000 G4 Operators Manual [Internet]. Atlanta, Georgia: Statim; c2013 [2013 November 27]. Available from: http://www.scicanusa.com/site/scicanusa/assets/pdf/scican_statim_g4_ops_usa.pdf • Venkatasubramanian, R., Jayanthi, Das UM, Bhatnagar, S. Comparison of the effectiveness of sterilizing endodontic files by four different methods: an in vitro study. J Indian SocPedod Prevent Dent. 2010 Jan-Mar. Vol 28 Issue 1: p: 2-5.
Please enjoy our video on the tutorial of the Statim G4 2000! • http://youtu.be/dog8jmIZf4c