170 likes | 212 Views
QUALITY AIR DISTRIBUTION PRODUCTS Air Terminal Induction Chilled Beam Flow Schematics – Air Terminal Chilled. QUALITY AIR DISTRIBUTION PRODUCTS CFD of a ceiling model. QUALITY AIR DISTRIBUTION PRODUCTS Air Terminal Induction Chilled Beam. EB AIR- Terminal Induction Models.
E N D
QUALITY AIR DISTRIBUTION PRODUCTSAir Terminal Induction Chilled Beam Flow Schematics – Air Terminal Chilled
QUALITY AIR DISTRIBUTION PRODUCTSAir Terminal Induction Chilled Beam EB AIR- Terminal Induction Models 2 WAYS THROW- 1X4 –BOTTOM VIEW 2 WAYS (2X2) THROW 2 WAYS (2X2) THROW-TOP VIEW 1 WAY THROW-1X4 TOP VIEW 1 WAY THROW (2X2) –BOTTOM VIEW 1 WAY THROW-1X4 –BOTTOM VIEW
QUALITY AIR DISTRIBUTION PRODUCTSAir Terminal Induction Chilled Beam Actual units for projects
QUALITY AIR DISTRIBUTION PRODUCTSAir Terminal Induction Chilled Beam High Capacity Units ( Single+ Double units) Single ATCBU Double ATCBU Double ATCBU
QUALITY AIR DISTRIBUTION PRODUCTSAir Terminal Induction Chilled Beam EVOLUTION • From Induction unit – the idea developed • Ceiling mounting for better coverage • High capacity to bigger loads • No Moving parts/ No Maintenance • Low Noise • Aerodynamic Nozzles and better Induction • All packaged in a compact box
QUALITY AIR DISTRIBUTION PRODUCTSAir Terminal Induction Chilled Beam When not draining the pan, float switch sends signal to CCD controller to shut the water valve so no more water entering the coil, if ½” or more condensate collects on drain pan.
QUALITY AIR DISTRIBUTION PRODUCTSInduction Unit Inductionunit(Type ML) High Capacity Induction Unit (Type HVMG)
QUALITY AIR DISTRIBUTION PRODUCTSInduction Unit • Used in retrofit application and new building designs • Basic Models : Low Boy ML and MG, Available in various heights 11.42”, 22.87”,17.38” . Four basic sizes model 48 -24.25” length , model 64 -30.50” length, model 88 -40” length, model 120 -52.50” length • 2pipe ( 1 Row, 2 Row) & 4 Pipe coil configurations available to meet various loads • Low primary air pressure design with extremely low noise due to efficient nozzle configuration • Higher Induction Ratio’s ( 2.4 to 5.5) can be achieved at lower primary air pressure
QUALITY AIR DISTRIBUTION PRODUCTSTest of Induction unit performance Unit Measurement using various probes Air Velocity + Total Air
QUALITY AIR DISTRIBUTION PRODUCTSInduction Unit Test set up at ETL Lab Various tests were carried out both on Induction unit and ceiling Induction Chilled Beam to validate performance of capacity, throw and noise. We tested several models to highlight performance on conditions as required on different projects.
QUALITY AIR DISTRIBUTION PRODUCTSInduction Unit Low Boy(Type ML) Tall Boy Induction Unit (Type MG) Horizontal Bulkhead Induction (Type HMG)
QUALITY AIR DISTRIBUTION PRODUCTS Active Chilled Beam