RFX-mod Diagnostic Status and Plans S.Martini on behalf of the RFX Team

RFX-mod Diagnostic Status and Plans S.Martini on behalf of the RFX Team. Introduction 2008 “new entries” 2009 plans Conclusions. FIR polarimeter operational and providing data New measurements: edge T e and n e from He lines intensity ratio, impurity injection by laser Blow-off,

duc
Download Presentation

RFX-mod Diagnostic Status and Plans S.Martini on behalf of the RFX Team

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. RFX-mod Diagnostic Status and PlansS.Martinion behalf of the RFX Team RFX-mod Programme Workshop 2009 – 20-22 January 2009

  2. Introduction • 2008 “new entries” • 2009 plans • Conclusions RFX-mod Programme Workshop 2009 – 20-22 January 2009

  3. FIR polarimeter operational and providing data New measurements: edge Te and ne from He lines intensity ratio, impurity injection by laser Blow-off, q-profile from H pellets ablation cloud desorption diagnostic edge Thomson scattering RFX Achievements 2008 RFX-mod Programme Workshop 2009 – 20-22 January 2009

  4. First polarimeter measurement in RFX-modF. Auriemma, M. Brombin, A. Canton, E. Zilli • Scope • Reconstuction of BΘ profile by measurements of faraday angle. • Details • 5 + 1 channels • FIR radiation at 118.8 μm • Measurements range between 5° and 10° • Time resolution 1÷3 ms • Measure Faraday angles with error < 10% • Future plans • Installation completed during spring 2008 • Measure of the magnetic axis position • BΘ profile computed by Abel inversion • Equilibrium computed using polarimetric measurements as constraints RFX-mod Programme Workshop 2009 – 20-22 January 2009

  5. FIR polarimeter chord layout 6 vertical chords (5 active) ch1 ch2 ch3 ch4 ch5 ch6 FIR radiation: l=118.8 mm RFX-mod Programme Workshop 2009 – 20-22 January 2009

  6. Sample polarimeter measurementshigh current & density #25570 MODEL: m&p ne$ [1-(r/a)15] measurements RFX-mod Programme Workshop 2009 – 20-22 January 2009

  7. Polarimeter summary • first faraday rotation measurements on 5 calibrated chords in high current RFX-mod discharges • ...to do: • residual oscillations at the end of the pulse • automatic calibration procedure • enhancing and stabilizing FIR laser output power • 1 broken beam splitting grid new beam splitting system with quartz plates better beams alignment • installation chord #1 RFX-mod Programme Workshop 2009 – 20-22 January 2009

  8. Thermal Helium Beam (THB) A He atomic beam injected into plasma and 3 of its emission lines (at 667.8, 706.5 and 728.1 nm ) observed. Light collected from 8 different radial positions, 0 to 35 mm with a spatial resolution of 5 mm. A spectrograph is used as polychromator. The lines can be observed by: a CCD with a time resolution of ~100 µs, 3 multianode PMTs for a resolution up to 10 µs. RFX-mod Programme Workshop 2009 – 20-22 January 2009

  9. Thermal Helium Beam (THB) An example of results obtained using THB with CCD cameras: time evolution of edge radial profiles of Te, ne and Pe. At the end of 2008 PMTs have been installed. After calibration and tests, first plasma signals have been collected. RFX-mod Programme Workshop 2009 – 20-22 January 2009

  10. Same laser used for edge Thomson scattering and LBO, with a beam splitter allowing the simultaneous activation. First injections carried out ablating a Ni target, a well-suited impurity for transport studies in RFX-mod plasma. Different target thickness and optic configurations tested to optimize the Ni ablation. Laser Blow-Off (LBO) RFX-mod Programme Workshop 2009 – 20-22 January 2009

  11. Shot #24073 at 1.2 MA. Top: line integrated SXR brightness. Centre: Te by double filter diagnostic. Bottom: dominant mode m=1,n=-7 and secondary mode m=1,n=-11 Sample: LBO inside QSH Island LBO provide Ni source inside QSH island, allowing the study of impurity transport. Lines Ni XVII and Ni XVIII (249 & 292 Å) observed, together with SXR emissivity increase -> Ni entered inside hot structure. RFX-mod Programme Workshop 2009 – 20-22 January 2009

  12. Using new fast CMOS camera, first safety factor profile, q(r), measurements in RFX-mod by observing ablation cloud of H pellets. q profile from pellet ablation cloud • Cloud angle has been measured RFX-mod Programme Workshop 2009 – 20-22 January 2009

  13. First measurements prove the possibility to measure q(r). Spatial resolution and accuracy to improve with Li pellet injector thanks to lower pellet speed and more elongated cloud. q profile from pellet ablation cloud • profiles agree with toroidal equilibrium model RFX-mod Programme Workshop 2009 – 20-22 January 2009

  14. To seek better density control during operation, new diagnostic, DESO, implemented A series of dummy openings before each RFX-mod shot improves piezo valves flow reproducibility. By processing time evolution of in-vessel pressure, DESO computes both total number of particles supplied by the valve system and total number of particles outgassed from wall and extracted by pumping system. DESOrption diagnostic RFX-mod Programme Workshop 2009 – 20-22 January 2009

  15. DESO measurements, coupled to other diagnostics data (masses of injected pellets, mass spectrometer measurements of particles removed from wall during He GDC’s), allows to compute 3 parameters : Des% Desorption Factor -> ratio between particles extracted after pulse end and total ones fuelled. DeltaPart Number of particles left in the wall after each shot -> difference between total fuelled particles and outgassed ones (in case of He GDC extracted particles are subtracted), TotPart -> total number of particles stored in the wall since last baking or boronization procedure, computed as sum of DeltaPart for all shots since last wall conditioning. DESOrption diagnostic RFX-mod Programme Workshop 2009 – 20-22 January 2009

  16. Des% describes wall capability to absorb particles in each shot. Correlates to I/N values more than TotPart: a non-absorbing wall (Des%>100%) forces I/N to 210-14Am, corresponding to maximum sustainable ne. Conversely, DeltaPart behavior shows that more particles are stored in the wall at each shot, i.e. an effective way to prevent wall particle accumulation has not yet been found. DESOrption diagnostic RFX-mod Programme Workshop 2009 – 20-22 January 2009

  17. Edge Thomson Scattering • Single pulse ruby laser (7J @ 694nm, 30ns at FWHM) focused on a 3mm pin-hole in vacuum. • Sapphire lens & prism deflect beam by 30° and image the pin-hole in vacuum vessel. • A camera lens (f=83mm / F#1.2) collects light at ~150°from 16 positions over f=1mm fibers: • 12 scattering volumes for Te, ∼10mm resolution; • 4 measuring points for detecting background plasma light. • The entrance port hosts the input system & the collection window  stable alignment. • Fibers are arranged in a 4x4 pattern and fed into a 4 spectral channels spectrometer. • An Intensified CCD (ICCD) acquires the Thomson and the Background signal RFX-mod Programme Workshop 2009 – 20-22 January 2009

  18. Edge Thomson Scattering Example of measure Red: edge Ts Blue : closest main Ts profile #25119,n 8E19 Done: acquisition has shifted from CCD camera to fast APD Status: able to measure for n> 3 x 1019 Fiber coupling and optics rearrange should shift limit to 1 x 1019 To reach lower limits a mechanical modification needed (to overcome vignetting of external channels) RFX-mod Programme Workshop 2009 – 20-22 January 2009

  19. 2009 plans Acquiring new diagnostics in order to : Improve fundamental data set (NPA) Supplement operation of NBI on loan from TPE-RX (FILD). Enhance analysis capability at high current (Li NB diagnostic) Completion / development 2008 activities RFX-mod Programme Workshop 2009 – 20-22 January 2009

  20. Ti measurement from NPA A Neutral Particle Analyser (NPA), based on re-ionization and magnetic deflection has been borrowed from the Max Planck Institute in Greifswald 22 channels analyse the ion (H,D) distribution function in the 0.2-30 keV energy range. RFX-mod Programme Workshop 2009 – 20-22 January 2009

  21. Ti measurement from NPA the 11 (H) channels of NPA system will be used to measure Ti and detect fast ion tails. Fast data acquisition will allow 50ms count windows. Data will be analyzed using Monte Carlo codes simulating neutrals production inside the plasma: utilize modified Nené code, originally developed to reconstruct particle source term in transport simulations. RFX-mod Programme Workshop 2009 – 20-22 January 2009

  22. Fast Ion Losses Diagnostic (FILD) To supplement high power NBI injector on loan from TPE-RX, a fast-ion diagnostic will study losses due to instabilities. 2009 dedicated to a feasibility study to identify the best solution between: Magnetic collimator spectrometer Faraday cup collector RFX-mod Programme Workshop 2009 – 20-22 January 2009

  23. FILD Top and side view of collimator. Gyroradius (energy) of the particle determines how far from the aperture it strikes the scintillator (left). Pitch angle determines where it strikes along the orthogonal dimension (right). RFX-mod Programme Workshop 2009 – 20-22 January 2009

  24. FILD • Depending on their energy, they pass a number of foils before being stopped, thus causing a current signal. FILD realized with a Faraday cup collector: Charged particles penetrate through a stack of conducting foils, separated by insulating foils. RFX-mod Programme Workshop 2009 – 20-22 January 2009

  25. Lithium neutral beam diagnostic A 35 keV Li beam with current of 1 mA will penetrate the plasma up to ne~2·1019 m-3. ne profile obtained from intensity of selected spectral Li lines measured by a CCD camera and an array of 16 avalanche detectors ne profile with high spatial resolution and bandwidth of 100 Hz ne fluctuation at 16 radial positions up to 500 kHz. RFX-mod Programme Workshop 2009 – 20-22 January 2009

  26. Lithium neutral beam diagnostic Collection optics (left) and poloidal section (right) for TEXTOR Lithium beam diagnostic RFX-mod Programme Workshop 2009 – 20-22 January 2009

  27. Completion / further development 2008 activities Upgrade of the Diagnostic Neutral Beam Injector CXRS affected by high background due to natural charge exchange processes, particularly in outer plasma region. Maximization of optical throughput in 2008 did not increase signal enough to disentangle active CX component from dominating passive one. =>To increase the active CX emission, an upgrade of the beam performance is called for. Best solution is to decrease beam divergence with new extraction and acceleration grids. This will increase the beam current density, and favor both MSE and CXRS measurements. RFX-mod Programme Workshop 2009 – 20-22 January 2009

  28. Increased optical etendue insufficient: CX signal still dominated by passive component. Simulations (Von Hellermann code) suggested looking at O VIII rather than C VI. Yet monitoring O VIII line @ 6068 Å with highly luminous high resolution spectrometer yielded no active CX signal. Passive O VIII core plasma emission provided Ti evaluation, although uncertainties on transport coefficients and measurement geometry do not permit to exactly define radial measuring position: at high density Ti~Te , at intermediate ne Ti ~ 50% Te,, while at low ne O emission too low for Doppler broadening evaluations. MST experience suggests using UV emission lines (larger effective CX cross sections) -> Calculation of such lines added in simulations and new diagnostic layout being designed, to compensate for optical fibers losses. Diagnostic Neutral Beam: Ti measurements RFX-mod Programme Workshop 2009 – 20-22 January 2009

  29. Hα measurements provided a weak beam emission signal that will be used for a first attempt to estimate Bt in the center. However the weakness of the signal confirms need to restore injector current at least to original value( 2.5 equivalent A) and that smaller beam divergence should be sought for, possibly by changing the extraction grids. Diagnostic Neutral Beam: Bt measurements RFX-mod Programme Workshop 2009 – 20-22 January 2009

  30. Completion/further development 2008 activities Microwave reflectometer After successfull commissioning of first band, installation of the other 4 bands planned for 2009. Soft X-Ray (SXR) diagnostics New horizontal SXR camera Various mechanical parts have been built and will be completed in 2009. Most electronics purchased and tested. The diagnostic will be installed on RFX in the first part of 2009. SXR Multifilter Supplies the core Te by two-foil technique. Planned to upgrade from 4 to 6 channels with an improved chord layout. Tomography vacuum and control system The new vacuum system and control computer will be installed in the first shutdown of 2009. RFX-mod Programme Workshop 2009 – 20-22 January 2009

  31. Completion/further development 2008 activities Edge measurements Temperature and density profile from thermal He beam A first set-up, consisting of a spectrometer coupled to a CCD camera, gave Te and ne in with a time response of 80 ms at 3 radial positions. The spectrometer will be modified to accomodate 3 slits coupled to photomultipliers for a time response up to 2 MHz, suitable for Te and ne fluctuations measurements Fast insertable pneumatic system for edge probes Following the feasibility study performed during year 2008, the system will be developed in 2009. Arcless power supply for ion saturation measurement Following the design activity performed in year 2008, the construction and test of the new power supply will be carried out. RFX-mod Programme Workshop 2009 – 20-22 January 2009

  32. Ka band (2640 GHz, ne: 0.92·1019m3), installed. First measurements show strong reflection when the ne > critical value : (fpe2 = e2ne/(4p2e0me) > fmw2) Signal post-processing to extract physical information in preparation. Other 4 bands in 2009 to get fast time evolution of a 5-point density profile Microwave Reflectometer RFX-mod Programme Workshop 2009 – 20-22 January 2009

  33. In addition to temperature, plasma density and potential measurements added. Measurement circuit rebuilt => range of temperature measurement doubled. System for protecting circuits from plasma arcs tested and installed. New acquisition system based on optical fibers: sampling frequency increased to 5 MHz. Effect of magnetizing winding currents (up to 50 kA) on optical transmitters reduced by positioning close to vacuum vessel. Upgrade of triple Langmuir probe RFX-mod Programme Workshop 2009 – 20-22 January 2009

  34. impurity pellet injector • Injector characteristics • Pellet speed: 50÷200 m/s • Pellet size: Ø0.5÷2 mm x 1÷3 mm • Magazine: 30 pellets • Material: Li, C, B • Aims • Measurement of the pitch of the magnetic field lines • Transport studies • First wall conditioning RFX-mod Programme Workshop 2009 – 20-22 January 2009

  35. Interface to RFX-mod designed and ordered. Important preparation activities completed: Lithium handling and pellet preparation tools have developed Tests done to determine vacuum pumping requirements to limit driver gas injection into RFX-mod. Sabot loading parts re-design improved launch system reliability and reduced running manpower requirements. Injector to be installed in early 2009. Impurity pellet injector RFX-mod Programme Workshop 2009 – 20-22 January 2009

  36. Most of the electronics (acquisition) purchased; 2 prototype amplifiers tested, defining the final version of the amplification stage. The various parts of the diagnostic have been built but the final on RFX-mod will occur in 2009 New horizontal SXR camera RFX-mod Programme Workshop 2009 – 20-22 January 2009

  37. Completion/further development 2008 activities Impurity pellet injector Due to delay in designing injector/machine interface, injector will be mounted in beginning of 2009. It will be used with Lithium for wall conditioning and for magnetic pitch angle measurements using the new fast CMOS camera. Impurity transport studies will be also performed. RFX-mod Programme Workshop 2009 – 20-22 January 2009

  38. RFX-mod diagnostics present & future RFX-mod Programme Workshop 2009 – 20-22 January 2009

  39. RFX-mod diagnostics present & future RFX-mod Programme Workshop 2009 – 20-22 January 2009

  40. Conclusions Some interesting new diagnostics became fully operational in 2008 Others made progress and should be available before summer 2009 This makes the diagnostic data set reacher and should entice more challenging experimental proposal for the RFX-mod experimental program Developement work continues and “new entries” are expected also for next year RFX-mod Programme Workshop 2009 – 20-22 January 2009