1 / 10

TITLE

TITLE. INVESTIGATION OF A SINGLE CRYSTAL DIAMOND SENSOR AND ITS APPLICATION IN BACKGROUND MEASUREMENTS FOR HERA Wolfgang Lange, DESY Zeuthen. 1. 3rd NoRDHia Workshop @. OUTLINE OF THIS TALK. Motivation The Sensor Measurements Static Measurements Particle Detection (Source)

dussery
Download Presentation

TITLE

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. TITLE INVESTIGATION OF A SINGLE CRYSTAL DIAMOND SENSOR AND ITS APPLICATION IN BACKGROUND MEASUREMENTS FOR HERA Wolfgang Lange, DESY Zeuthen 1 3rd NoRDHia Workshop @

  2. OUTLINE OF THIS TALK • Motivation • The Sensor • Measurements • Static Measurements • Particle Detection (Source) • Charge Collection during Irradiation • Results • Outlook 2 3rd NoRDHia Workshop @ Wolfgang Lange

  3. Investigation of one of the first available single crystal diamond sensors • Not only measurement of properties but also practical use in an application to achieve experience • Extend this application into environments with radiation load later MOTIVATION 3 3rd NoRDHia Workshop @ Wolfgang Lange

  4. Single Crystal (CVD grown on substrate) by E6 • About 5 by 5 square millimeters • Metallization 3 mm in diameter • Thickness 320 µm • Connected via ultrasonic Al bonding SENSOR 4 3rd NoRDHia Workshop @ Wolfgang Lange

  5. HV Diamond Keithley 487 N2 MEASUREMENTS (1) 5 3rd NoRDHia Workshop @ Wolfgang Lange

  6. MEASUREMENTS (2) 6 3rd NoRDHia Workshop @ Wolfgang Lange

  7. Charge Collection Distance: MEASUREMENTS (3) CCD reaches maximum @ 50V (100% efficiency, thickness = 320 µm) 7 3rd NoRDHia Workshop @ Wolfgang Lange

  8. Charge Collection Distance: MEASUREMENTS (4) CCD @ 80V (100% efficiency, thickness = 320 µm), measured for low doses (Sr90) 8 3rd NoRDHia Workshop @ Wolfgang Lange

  9. 100% charge collection efficiency, CCD = thickness • Stable for low doses • Clearly separated spectrum of minimal ionizing particles • 1 mip results in 11.5 ke- (1.84 fC) RESULTS 9 3rd NoRDHia Workshop @ Wolfgang Lange

  10. application of this sensor in particle counting: • use of a preamplifier, put it in a box, interface electronics • appointed application: radiation monitor (HERA, Zeus) OUTLOOK 10 3rd NoRDHia Workshop @ Wolfgang Lange