An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Measuring points location

  2. Overall vibration level trend according to ISO Vs. High frequency band level trend High Frequency band From 1 KHz to 10 Hz ISO Standard Band From 10 Hz to 1 KHz

  3. Overall vibration level trend according to ISO Vs. High frequency band level trend High frequency band level trend From 1 KHz to 10 KHz Acceleration Overall vibration level trend according to ISO From 10 Hz to 1 KHz Velocity

  4. The Envelope spectrum shows the outer race bearing defect frequency and its harmonics

  5. The High frequency spectrum after lubrication shows disappearance of the high frequency area The Envelope spectrum after lubrication shows the disappearance of outer race bearing defect frequency

  6. The High frequency spectrum and the Envelope spectrum before and after lubrication High Frequency spectrum Before Lubrication High Frequency spectrum After Lubrication Envelope spectrum After Lubrication Envelope spectrum Before Lubrication