1 / 8

Directory Structure

Directory Structure. We have 3 algs under MuonRawDataMonitoring: RPCLV1, RPC and MDTvsRPC The shifter plots are under the subdirectory Dqmf for each algs The Dqmf algs are applied to the shifter plots. RPCLV1 shifter plot 1. Description of the variable:

dyani
Download Presentation

Directory Structure

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Directory Structure We have 3 algs under MuonRawDataMonitoring: RPCLV1, RPC and MDTvsRPC The shifter plots are under the subdirectory Dqmf for each algs The Dqmf algs are applied to the shifter plots.

  2. RPCLV1 shifter plot 1 • Description of the variable: • Combination of phi view RPC layers that caused the trigger versus RPC Sector Logic. • The first group are about LowPt RPC and the second group about RPC highPt • Expected features of the histogram: • We should have populated: • LPt combination with at least 3 layers • HPt no combination with L=1 and only combination with 3 layers • DQMF algs: reference itself

  3. RPCLV1 shifter plot 2 Description of the variable: BcId from 0-7+Shift for for phi view RPC trigger hits vs RPC Sector Logic. Shift=0 for LowpT and Shift=8 for HighPt Expected features of the histogram: We should have populated mostly one bcId+Shift. But the time alignment is in progress and a much larger spread is expected. DQMF algs: reference itself

  4. RPCLV1 shifter plot 3 Description of the variable: BcId from 0-7+Shift for phi view RPC trigger hits vs trigger type. Shift=0 for LowpT and Shift=8 for HighPt. Expected features of the histogram: We should have populated mostly one bcId+shift. But the time alignment between other LV1 detector is in progress and a much larger spread is expected. DQMF algs: reference itself

  5. RPC shifter plot 1 Description of the variable: The distribution of the log10 average occupancy of the RPC strip panels Expected features of the histogram: Most of the panel should have an occupancy less than 0.1 (log10=-1) and more than 0.0001 (log10=-4) DQMF algs: Number of panels with an average occupancy between MIN and MAX must be bigger than THRESHOLD

  6. RPC shifter plot 2 Description of the variable: The distribution of the average efficiency of the RPC strip panels measured by RPC standalone tracking. Expected features of the histogram: Most of the panels should have an average efficiency bigger than 0.9. DQMF algs: Number of panels with an average efficiency larger than MIN must be bigger than THRESHOLD

  7. RPC shifter plot 3 Description of the variable: The distribution of the rms value of RPC hits belonging to a RPC standalone track. Expected features of the histogram: We should have a spread less than one bunch crossing, but the time alignment is in progress and a much larger spread could be expected. DQMF algs: RMS Histo must be less than THRESHOLD

  8. MDTvsRPC shifter plot 1 Description of the variable: The distribution of the spatial residual along z (bending view) between a RPC hit and a MDT hit of adiacent RPC plane and MDT multiplayer. Expected features of the histogram: We should have a distribution centered in zero and with spread less than 20 cm. DQMF algs: The Sigma of the Histo Gaussian fit must be less than THRESHOLD

More Related