LP Series U Uninterruptible Power Supply Technical Specification & Features. LP Series U. Technical presentation. ISO 9001 UL CUL FCC Class A CE. Key Features & Benefits. True On-Line Double Conversion … provides highest level of power reliability
E N D
LP Series UUninterruptible Power SupplyTechnical Specification & Features
LP Series U Technical presentation ISO 9001 UL CUL FCC Class A CE
Key Features & Benefits • True On-Line Double Conversion … provides highest level of power reliability • Fully isolated output … additional power fault protection • Power factor corrected input (>0.99) … clean input • Scalable Using GEDE’s Unique “Redundant Parallel Architecture (RPA) … maximum reliability • Superior battery management … enhanced battery life time • ECO-mode … energy savings for less critical loads e.g., during off hours, emergency lights etc • Small Footprint … easy to place
Key Features & Benefits (continued) • Excellent inrush current handling… prevents tripping protection devices • Superior overload handling … protection against unplanned overloads • Minimal Output Voltage Distortion of <3% … stable power for the load • Multi-functional LCD screen … easy to operate • Multi language display … Spanish etc • Automatic battery testing – every 500 hrs.… no “surprises” • Cold start … unit can be started with no AC present • No load shutdown… prevents unnecessary discharging of batteries
Key Features & Benefits (continued) • Backfeed relay… maximum safety • EPO- Emergency Power Off… maximum safety • Multiple I/O voltages … 120,240, 208 VAC • Alarm interface : RS 232 and OC contacts … easy to integrate with existing systems • Redundant power supply for critical functions (LCD, Bypass) … increased reliability • UL, C-UL and CE markings for world-wide applications ...fits to many different mains voltages
Product Specifications LP Series 8-11U 8 kVA - 6.4 kW LP Series 10-11U 10 kVA - 8 kW LP Series 5-11U 5 kVA- 4 kW LP Series 6-11U 6 kVA - 4.8 kW Voltages and Frequencies Output Voltage • 120 + 208 + 230/240 • Fully isolated, even in bypass mode Output Frequency • 50 or 60 Hz • (Front Panel Selectable) Input Voltage • 208 – 230/240 • 120 V option (for 5/6 kVA only in additional transformer cabinet; Input Frequency • 45-65 Hz Flexible input and output voltages and frequency
Operating Mode True On-Line- double conversion • Bypass enable / disable … in frequency conversion mode no alarms … in case of weak mains protects the equipment against operations on mains • Programmable frequency tracking range(2%, 4%, 6%) … compatible with gen-sets with wider frequency range • HF PWM technique … compact design , low-losses, excellent characteristics Output Completely Independent of Input Voltage and Frequency
LP Series U Front Panel • LCD screen 2 lines with 16 characters - Information Screen status and alarm messages - Service screen internal settings test screens • Set Up Screen setting of parameters • Push buttons (keypads to scroll up, down, reset and enter) • LED operation / alarm status • On/Off switch turns unit on/off completely, including bypass on back of unit
Rear Panel On/Off switch turns unit on/off completely, including bypass Manual Bypass Battery fuses Utility & Bypass Protection Magnetic Circuit breakers for overload or short circuit in the UPS load I/O terminals RS232/contact interface/EPO Conduit box Optional: SNMP or relay card EMI Optional: RPA card Cable entry DC Connector for external batteries
Isolation on bypass EMI protection on bypass I/O terminals Surge protection RFI Filter Isolation transformer always active Battery charging capacity up to 60 minutes run time without additional charger Technology without compromise MANUAL BYPASS No inrush current during start up Bypass MCB Elektronic Bypass Backfeed protection Mains MCB 120/240 H bridge 208 HF input Output Converter RFI converter GND Filter 208 120/240 External Battery LCD Stepdown Internal Converter Supply Batteries up enter down operation alarm General alarm, Utility failure 4X optional 120 Volt auto-input xfrmr Bypass active, Batterey low L N L UPS Shutdown MICRO- processor CONTROL L RS232 External Emergency battery shutdown disconnected INTERFACE Option: SNMP card
THD-I < 10% PF 1 input converter Technology with Premium Performance Input voltage:187-285 V at 100% load Bypass MCB RFI Input voltage: 150-285 V at 50 % load internal supply F3 P Line MCB N
Technology : Output Converter Inverter DC Isolation on bypass 240 V Bypass +380V voltage 208V Output HS EMI F3 H-BRIDGE C2 Output converter C1 current Output 2x 120 V 1x 120 V 208 V 240 V transformer temp.sensor Heatsink 4X IGBT temp.sensor Fan speed controlled by load & heat sink temperature
Battery Specifications • Standard 20 X batteries 12V/7Ah (5/6kVA) or 12V/12Ah (8/10kVA) • Charge voltage = 271V, 13.55V/battery • Constant current/constant voltage characteristic + boost charge current is ± 0.3 C • Temperature protected till 45ºC • Battery extension up to 500 Ah • Battery capacity programmable over LCD/serial port
Superior Battery Management Ripple-free Boost Charging Temperature Compensated Charging Load dependent end of discharge voltage No-load Shutdown Automatic Battery Test /every 500 hours Deep Calibration Test Load dependent runtime prediction Load dependent battery low signal Maximum Up-time Prevents Damage Prolonged Battery Lifetime No Surprises
Output Performance • Output THD < 3% for linear loads • Output Power Factor = 0.8 • Output filter performance control enabling robust operation • Fully isolated output • Protected against: • Low/high DC voltage • Over-temperature • Overload • AC on Output • Short circuit No Compromise on Output Performance
Manual Bypass Bypass Switch Hall Sensor Bypass MCB thyristors to output-transformer Output current Line MCB L1 UPS L2 Bypass Specifications • Bypass input voltage -10 to +10% • Bypass frequency window selectable 2%, 4%, 6% • Tracking rate 1 Hz/sec “low”, 5 Hz/sec “high” • Protected against overload • Short circuit protection • Galvanic isolation State-of-the-art Bypass
Communication • Standard: RS 232 dialogue UPS shutdown Emergency Power off ( EPO ) External DC - fuse alarm • Optional: SNMP - card RS 232 is not available if SNMP is installed Dry contacts Easy to integrate into computer network
Available Options Power Distribution unit (PDU) External battery cabinets External battery cable Seismic anchor SNMP interface card Relay interface card RPA kit (Redundant Parallel Architecture) Alarm boxes Connectivity products, like Splitter box; interface kits; interface software for all common OS, incl Java 120 Volt input voltage transformer/cabinet