Yet More on Clocks

Yet More on Clocks. Peter and John. New bias network for AC coupled BCO. Original version left 120mV DC bias between the two inputs Alternative shown suggested by Dave Nelson and Dieter Freytag (SLAC)

dyre
Download Presentation

Yet More on Clocks

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Yet More on Clocks Peter and John

  2. New bias network for AC coupled BCO • Original version left 120mV DC bias between the two inputs • Alternative shown suggested by Dave Nelson and Dieter Freytag (SLAC) • Implemented on the stavelet by PWP (for H0 only – others unchanged) using 0603 components mounted vertically 2V5 33k 33k

  3. How did we do? H0 post blocking C, 68R ET, 100R BT H0 Recovered BCO, 68R ET, 100R BT => Looks great! Next: vary back termination (0R < X < 100R) to explore margins

  4. H0: Recovered BCO, 56R ET, X1 BT H0: BCO pre blocking C, 56R ET, X1BT H0: BCO pre blocking C, 56R ET, X2BT H0: Recovered BCO, 56R ET, X2BT

  5. H0: Recovered BCO, 56R ET, X3BT H0: BCO pre blocking C, 56R ET, X3BT H0: BCO pre blocking C, 56R ET, X4BT H0: Recovered BCO, 56R ET, X4BT

  6. Can we predict amplitude at capacitor inputs, using MLVDS driver, after 24 drops? Amplitude (mV) 380mV Drop number

  7. Crystal Ball Time • For a 24 drop stave built to the same tape geometry, we can extrapolate the stavelet data to predict the amplitude at the end of the BCO bus • Predict 380mV, 56R end term, 100R back term • We have tested the BCC board with the new bias network for several input amplitudes • 340mV gives 51.8% duty • 186mV gives 52.3% duty • 120mV gives 54.6% duty (limit for ABCN) • Prediction • A stave using BCC V2 with the modified circuit should work just fine! Even looks like we have a factor >2 safety.

  8. This looks great – but... • Caveat • Need to try a chain of many boards with the new circuit to confirm this, not just one • Modifying the card on the stavelet was very tricky, it would be much safer to do this with an alternate“testvehicle” • Any volunteers with suitable facilities? • We could maybe replace the BCC boards on the stavelet with new ones? • I would strongly recommend this be tested before any decision be made to leave BCO clock regeneration out of BCC V3. • Having said that – it looks like we won’t need it ;-)