1 / 12

AATS Aortic Symposium 2010 ▪ New York ▪ April 29-30, 2010

D-dimer level remains a highly sensitive test for acute aortic dissection beyond the first 24 hours after onset. Scott A. LeMaire, Ludivine Russell, Neal R. Barshes, Paul M. Allison, Dana E. Haas, Ying H. Shen, Dianna M. Milewicz, Joseph S. Coselli.

ebony
Download Presentation

AATS Aortic Symposium 2010 ▪ New York ▪ April 29-30, 2010

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. D-dimer level remains a highly sensitive test for acute aortic dissection beyond the first 24 hours after onset Scott A. LeMaire, Ludivine Russell, Neal R. Barshes, Paul M. Allison, Dana E. Haas, Ying H. Shen, Dianna M. Milewicz, Joseph S. Coselli AATS Aortic Symposium 2010 ▪ New York ▪ April 29-30, 2010 This study describes an unlabeled/investigational use of the Siemens Advanced D-dimer Assay, i.e. for the diagnosis of acute aortic dissection.

  2. Study Objective • D-dimer has been proposed as a highly sensitive biomarker to detect acute aortic dissection Elefteriades et al ▪ Cardiology 2008 • Recent data from the International Registry of Acute Aortic Dissection Substudy on Biomarkers (IRAD-Bio) show that D-dimer levels obtained within the first 24 hours after symptom onset had a 96.6% sensitivity Suzuki et al ▪ Circulation 2009

  3. Study Objective • Some patients, particularly those with atypical symptoms, present for evaluation beyond the first 24 hours after onset of acute aortic dissection; it is unclear whether D-dimer levels would be useful in detecting dissection in these patients • The purpose of this study was to determine whether D-dimer levels remain elevated more than 24 hours after the onset of acute aortic dissection

  4. Methods • Institutional approval was obtained for the study, and written informed consent was obtained from all patients • Plasma samples were collected within 10 days after onset of symptoms from 100 patients with unrepaired acute aortic dissection • Whenever possible, serial samples were obtained over a period of 2 or more days • Samples were grouped according to day of collection relative to the onset of aortic dissection; an average of 25 samples were available for each day’s group, from day of onset (day 0) through post-dissection day 10

  5. Clinical Features

  6. Dissection Characteristics

  7. Methods • D-dimer levels were measured in the clinical laboratory by using the Siemens Advanced D-dimer assay (latex-enhanced immunoturbidimetric assay) on an automated coagulation analyzer BCS XP (range of detection, 0.4-55 µg/mL) • The approved cut-off for detecting venous thromboembolism for this assay is 1.6 µg/mL; this value was used as the diagnostic threshold • A post-hoc subgroup analysis was performed to explore whether clinical factors were associated with false-negative D-dimer levels in this cohort

  8. 40.0 Results 35.0 30.0 • The median D-dimer level for all plasma samples (n = 279) was 3.56 µg/mL (interquartile range, 2.55-5.60 µg/mL) • D-dimer levels exceeded the 1.6 µg/mL diagnostic threshold in 266 samples, yielding an overall sensitivity of 95.3% 25.0 20.0 D-dimer levels (μg/mL) 15.0 10.0 1.6 µg/mL threshold 5.0 0.0

  9. D-dimer levels remained markedly elevated throughout the 10-day post-dissection period; daily sensitivities ranged from 89 to 100% 40.0 35.0 30.0 25.0 D-dimer levels (μg/mL) 20.0 15.0 10.0 1.6 µg/mL threshold 5.0 0.0 • Days after onset 0 1 2 3 4 5 6 7 8 9 10 • n 7 27 26 33 26 27 27 30 31 21 24 • Sensitivity 100% 89% 89% 94% 100% 100% 96% 97% 97% 95% 96%

  10. False-negative results were significantly more common in samples obtained from patients without hypertension, with a history of coronary artery disease, or with DeBakey type II dissection • False-negative results did not appear to be related to patient age, intramural hematoma (vs classic dissection), Marfan syndrome, smoking, or cancer

  11. Conclusions • Elevated D-dimer levels remain a sensitive indicator of acute aortic dissection throughout the first 10 days after onset • Post-hoc analysis showed that the sensitivity of D-dimer may be reduced in certain subsets of patients, such as those with dissection involving only the ascending aorta (ie, DeBakey type II) • Although D-dimer testing may be helpful in detecting acute aortic dissection in patients with delayed presentation, further studies are needed to evaluate the impact of clinical factors on the sensitivity of this assay

  12. Acknowledgements • Dr. LeMaire is supported by a Thoracic Surgery Foundation for Research and Education/National Heart, Lung and Blood Institute Co-sponsored Mentored Clinical Scientist Development Award (K08 HL080085) • The Thoracic Aortic Disease Tissue Bank at Baylor College of Medicine is supported in part through the NIH Specialized Center for Clinically Oriented Research in Thoracic Aortic Aneurysms and Dissections (P50 HL083794; DM Milewicz, PI)

More Related