170 likes | 633 Views
Fresenius Medical Care Peritoneal Dialysis Connections. Safe-Lock to stay safe Connection. Connections using Fresenius Medical Care products.
E N D
Fresenius Medical Care Peritoneal Dialysis Connections Safe-Lock to staysafe Connection
Connections using Fresenius Medical Care products This inservice is not intended to replace the advice or training from your physician. Refer to the Instructions For Use (IFU) for detailed device description, instructions, contraindications, warnings, and precautions. Fresenius Medical Care, DEL-CLAMP, Stay●Safe, Safe-Lock, DELFLEX and FREEDOM are trademarks of Fresenius Medical Care Holdings Inc. or its affiliated companies. All other trademarks are the property of their respective owners.
Fresenius Products Baxter is a trademark of Baxter International Inc. or its affiliates. Instructions on how to use Baxter products were reproduced from the manufacturer’s literature and were current at the time of print. Instructions are included for the patient's convenience but Fresenius Medical Care North America does not specifically endorse the use of these products or assume any liability related to their use. Should there be any differences between the instructions listed in this manual and the instructions for use provided with the medical devices referenced, the instructions provided with the medical device should be taken as accurate."
Connections using Fresenius Medical Care products Note: for clarity the model is shown not wearing personal protective equipment (PPE). Follow your facility’s policies and procedures for use of personal protective equipment. It is vital to maintain sterility of the connectors during connection procedures.
Safe-Lock Systems Please note Safe-Lock systems include: • Delflex Premier Plus exchange set • Freedom Y-set with snap disconnect • All Freedom cycler tubing sets • Newton cycler set with safe lock connectors • 8 Lead Safe-Lock Manifold set
Safe-Lock Connections Catheter adapter on catheter 4 inch convertible extension set Extension set with roller clamp Premier transfer set Patient catheter or extension tubing segment with Del-clamp The patient’s Safe-Lock connector or extension set will look like one of the above. These are photos of the patient catheter or catheter extension set with a tubing segment secured with a DEL-CLAMPclamp attached.
Safe-Lock patient to staysafe system A staysafe Extension Set with Safe-Lock patient connector will allow the patient with a Fresenius Safe-Lock PD system to use staysafe supplies while in the hospital. staysafe Extension Set with Safe-Lock patient connector Safe-Lock PD system staysafe System
Safe-Lock patient to staysafe system Gather supplies staysafe Extension Set with Safe-Lock patient connector 12 inches (P/N 050-95001) or 18 inches (P/N 050-95002) staysafe supplies for procedure.
Safe-Lock patient to staysafe system Disinfectant chamber Segment secured with Del-clamp Remove the tubing segment secured with a DEL-CLAMP clampfrom the patient’s catheter and attach the stay●safe Extension Set. Add povidone – iodine solution to the top of threads in the disinfectant chamber. Proceed with the stay●safe exchange procedure.
DISCHARGE INSTRUCTIONSFOR ALL CONNECTIONS • The patient should return to his/her home or clinic with the additional extension in place. This practice will allow the patient to return home and resume dialysis without interruption. • Instruct the patient to remove any adaptors added to their extension set at the beginning of the next exchange or as directed by the PD clinic nurse.
Choose the type of catheter or transfer set and the type of system utilized. Look down the column and across the row to the adapter needed. Click on the icon in the box to take you to the procedure
Please contact your Fresenius Clinical Sales Representative at 1-800-662-1237 if you have questions regarding the use of a Fresenius PD system or adapter.
CD Available through Customer Service 800-323-5188 (P/N # 100676-01)