An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SVT software statusand plans Planning – Much work remains to be done before we can announce our total failure to make any progress. -despair.com

  2. SVT Installation

  3. Hardware Improvements • SVT partially disassembled and water fittings (4 per ladder) replaced on entire SVT • Upgraded vacuum-pressure water system monitoring and controls • Replaced some analog driver boards (Transition boards). • 2 outer ladders removed and had some wire bonds repaired (only possible to access outer layer without full SVT disassembly). • All 24 RDOs were removed for a number of repairs/improvements -Replace with new circuit old thermal cutoff switches that failed in magnetic field -Replace failed ADCs -Fix monitoring failures on HDLC link -Fix shifting of pedestals during calibration injection. -Reprogram for Level-2 accept/aborts. • Re-designed shielding to accommodate future SSD as well as prototype SSD ladder for this year. • Re-packaged cabling to accommodate future SSD

  4. SVT Performance • 91.2% of 103,680 channels operational • Noise • 12 mV for Au+Au • 7 mV for pp • ~30 mm resolution reproducibility counts cm

  5. SVT Heat up. Au-Au

  6. Charge vs Drift Some evidence of “charge loss” ~20% Probably trouble in cluster analysis. We “correct” for this currently by scaling to make flat. On ladder by ladder basis. Should really do this ladder by ladder – Even better fix software Drift Drift cm Center of wafer

  7. Better dE/dx and better position resolution Can see edges of PASA (not sure why) Performed by recoding mean charge on Anode Of many events assume min-ionising and force Each to a common mean Anode by Anode calibration

  8. Vertex Finding - Resolution p-p Nprim>10 sigma= 0.24cm cm Still slight offset of 0.05cm (agrees with residuals)

  9. Anode residuals BUT!!! Tilt would have to be 0.1 radians! Could be that separation of wafers is not correct but that requires a squeezing of 300 microns!! MUST! Be TPC problem Wafer 4 Wafer 2 Wafer 6

  10. Z res vs dip angle Shift in Z + TPC T0/Vdrift wrong Dip < 0.1 mean D(Z) = 0.0526cm vdrift = 5.56 cm/msec T0 shift = 0.0526/5.56 = 9.46 x 10-3 msec

  11. Vertex Finding - Data TPC cm SVT cm p-p

  12. Vertex Finding - Resolution p-p Z offset of 0.005cm – Aligned in Z

  13. Occupancy – Pile-up Global Primary RFF Good hits Good hits Global Primary FF Good hits Good hits

  14. Pile-up? Effic Effic FF RFF pt pt Effic Effic Hijing Au-Au FF (new) pt pt

  15. Track Matching

  16. Impact Parameter Improvement 3D impact parameters global track associated to primary pp Mean 0.7->0.51 cm RMS 0.59->0.48 cm TPC TPC+SVT

  17. Strange Particle Decays • Black is TPC only • Red is TPC+SVT • ~35-40% greater yield in K0s region Preliminary Preliminary • Blue is TPC only • Red is TPC+SVT • Mostly low pT

  18. Plans for Year 3 • Run! • Use ITTF • Global calibration between TPC & SVT

  19. Drift Residuals T0 wrong by ~3 time bins

  20. Drift Residuals vs Wafer Before Alignment Shifted to x=-0.276cm y=-0.82cm z=-0.192cm After Alignment Magnitudes agree with survey results

  21. Anode Residuals vs pt Au-Au After correction

  22. Energy Loss in the SVT Layers • 3 sample maximum • Higher energy resolution • Good for low momentum Preliminary Preliminary • Independent measure of dE/dx • Allows 2D cut