200 likes | 335 Views
Maryland Transportation Authority Police Training Facility. Schematic Design Presentation December 13, 2007 Leah Clark. Overview. Location: Hawkins Point, Baltimore, Maryland Size: • 42,100 square feet • 2 stories above grade Project Team:
E N D
Maryland Transportation Authority Police Training Facility Schematic Design Presentation December 13, 2007 Leah Clark
Overview Location: Hawkins Point, Baltimore, Maryland Size: • 42,100 square feet • 2 stories above grade Project Team: • Owner: Maryland Transportation Authority • Mechanical and Electrical: Johnson, Mirmiran, & Thompson • Architectural: Rubeling & Associates• Civil and Structural: Carroll Engineering, Inc.• Construction Manager: To be determined by competitive bid among prequalified biddersContractor: To be determined (by bid among prequalified contractors)
First Floor Front Façade Physical Training Gym Classroom ‘A’ Firing Range Area
Sections Classroom ‘A’ Firing Range Area Front Façade Physical Training Gymnasium
Sections Classroom ‘A’ Firing Range Area Front Façade Physical Training Gymnasium
Classroom ‘A’ Design Criteria Light Distribution of Task Plane Uniformity on task plane Peripheral Emphasis Control and Flexibility Variety of tasks Multiple switching options Illuminance Levels (to perform task)
Classroom ‘A’ Whiteboard Lighting Under-cabinet Lighting Zone 1 Suspended Direct-Indirect Lighting Whiteboard Zone 2 Zone 3 Zone 4 Zone 5 Projection Screen TV
Range Area Design Criteria Control and Flexibility Pseudo-realistic training environments Multiple lighting systems Control system with preset lighting scenes Illuminance Levels Vertical face of the targets Interior Conditions – 50 fc Exterior Conditions – 10 fc Horizontal illuminance in the shooting lines Interior Conditions – 20 fc Exterior Conditions – 1 fc Direct Glare Lower cutoff angles for fixtures
Range Area Dimmable Recessed Compact Fluorescent Lighting High Pressure Sodium Fixtures to simulate exterior night lighting scene Red LED Lighting to signal when firing lane is in use
Range Area Dimmable Recessed Compact Fluorescent Lighting Linear Fluorescent Lighting to simulate normal interior conditions Red LED Lighting to signal when firing lane is in use
Range Area Shooting Targets Floor Recessed Fixtures illuminate vertical face of targets
Physical Training Gymnasium Design Criteria Control and Flexibility Allow fixtures to be Multiple lighting systems Control system Illuminance Levels Highlight Exposed Structure Uplight ceiling joists
Front Facade Design Criteria Sense of Direction Higher light levels at entrance Points of interest Precast logos Light Pollution / Trespass Modeling of Faces and Objects Safety and security Security cameras Light Distribution on Surfaces Hierarchy of light
Front Facade Building Identification MdTA Police Logo MdTA Logo Standing Seam Metal Awning Main Entrance
Thank You Questions & Comments