1 / 20

Maryland Transportation Authority Police Training Facility

Maryland Transportation Authority Police Training Facility. Schematic Design Presentation December 13, 2007 Leah Clark. Overview. Location: Hawkins Point, Baltimore, Maryland Size: • 42,100 square feet • 2 stories above grade Project Team:

eldon
Download Presentation

Maryland Transportation Authority Police Training Facility

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Maryland Transportation Authority Police Training Facility Schematic Design Presentation December 13, 2007 Leah Clark

  2. Overview Location: Hawkins Point, Baltimore, Maryland Size: • 42,100 square feet • 2 stories above grade Project Team: • Owner: Maryland Transportation Authority • Mechanical and Electrical: Johnson, Mirmiran, & Thompson • Architectural: Rubeling & Associates• Civil and Structural: Carroll Engineering, Inc.• Construction Manager: To be determined by competitive bid among prequalified biddersContractor: To be determined (by bid among prequalified contractors)

  3. First Floor Front Façade Physical Training Gym Classroom ‘A’ Firing Range Area

  4. Second Floor

  5. Sections Classroom ‘A’ Firing Range Area Front Façade Physical Training Gymnasium

  6. Sections Classroom ‘A’ Firing Range Area Front Façade Physical Training Gymnasium

  7. Classroom ‘A’ Design Criteria Light Distribution of Task Plane Uniformity on task plane Peripheral Emphasis Control and Flexibility Variety of tasks Multiple switching options Illuminance Levels (to perform task)

  8. Classroom ‘A’ Whiteboard Lighting Under-cabinet Lighting Zone 1 Suspended Direct-Indirect Lighting Whiteboard Zone 2 Zone 3 Zone 4 Zone 5 Projection Screen TV

  9. Classroom ‘A’

  10. Range Area Design Criteria Control and Flexibility Pseudo-realistic training environments Multiple lighting systems Control system with preset lighting scenes Illuminance Levels Vertical face of the targets Interior Conditions – 50 fc Exterior Conditions – 10 fc Horizontal illuminance in the shooting lines Interior Conditions – 20 fc Exterior Conditions – 1 fc Direct Glare Lower cutoff angles for fixtures

  11. Range Area Dimmable Recessed Compact Fluorescent Lighting High Pressure Sodium Fixtures to simulate exterior night lighting scene Red LED Lighting to signal when firing lane is in use

  12. Range Area Dimmable Recessed Compact Fluorescent Lighting Linear Fluorescent Lighting to simulate normal interior conditions Red LED Lighting to signal when firing lane is in use

  13. Range Area Shooting Targets Floor Recessed Fixtures illuminate vertical face of targets

  14. Physical Training Gymnasium Design Criteria Control and Flexibility Allow fixtures to be Multiple lighting systems Control system Illuminance Levels Highlight Exposed Structure Uplight ceiling joists

  15. Physical Training Gymnasium

  16. Physical Training Gymnasium

  17. Front Facade Design Criteria Sense of Direction Higher light levels at entrance Points of interest   Precast logos Light Pollution / Trespass Modeling of Faces and Objects Safety and security Security cameras Light Distribution on Surfaces Hierarchy of light

  18. Front Facade Building Identification MdTA Police Logo MdTA Logo Standing Seam Metal Awning Main Entrance

  19. Front Facade