1 / 29

NSLSII Control System Overview

NSLSII Control System Overview. The Control Group – presented by Bob Dalesio NSLS-II ASAC Review October 14, 2010. Outline. Fast Orbit Feedback Component Development High Level Application Status Documentation of Facility in an Relational DataBase - IRMIS EPICS Extensions

elisabethr
Download Presentation

NSLSII Control System Overview

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. NSLSII Control System Overview The Control Group – presented by Bob Dalesio NSLS-II ASAC Review October 14, 2010

  2. Outline • Fast Orbit Feedback Component Development • High Level Application Status • Documentation of Facility in an Relational DataBase - IRMIS • EPICS Extensions • Control System Studio (CSS) Tools • Subsystem Status and Standards • Conclusions

  3. Orbit feedback system architecture Fast orbit feedback system in one cell

  4. Orbit feedback system architecture NSLS-II two tier device controller architecture Cell 1 Cell 30 Cell 2 Cell 29 Cell 3 Storage Ring SDI link SDI link Cell 17 Cell 15 Cell 16

  5. Fast Orbit Feedback – Time Budget 6.7 µs for BNL BPM Electronics delay to pipeline 3.7 µs for analog value averaged from raw data 3 µs estimated for BNL BPM Electronics 57 µs measured on Libera BPM Electronics with minimum filter 7 µs measured BPM data distribution by Shared Memory 14 µs measured when one of the redundant links not operational 4 µs measured for FOFB calculation with separate mode compensation 5 µs measured for set power supply by PS Shared Memory link 8 KHz measured for fast corrector PS bandwidth w 10 deg phase shift. 1 KHz measured for corrector magnet/chamber bandwidth. Measured on with Inconel beampipe. This value is at 10 degree phase shift. New magnet/chamber set up will be tested when they are available.

  6. Fast Orbit Feedback Test Stands Digital Front End Board and BPM analog electronics Digital Front End with Cell Controller I/O Soft IOCs PPS Test Stand Power Supply Controllers Power supply interface modules

  7. Fast Orbit Feedback • Digital Front End • redundant ring communication working at 2.5 Gbps • embedded event receiver with <5 psecs jitter and 8 nsecs of resolution. • Second spin will upgrade the FPGA from a Virtex 5 to a Virtex 6 – February time frame • Digital Front End (DFE) Used as Beam Position Monitor (BPM) Front End • raw analog at 116.9 MHz to Memory for up to 1 Gbytes • turn by turn data at 378KHz to Memory for up to 32 MB (2.5 seconds) • transfer of large arrays at under 2 minutes for under 32 MB over Modbus over Ethernet • transfer of large arrays at under 16 seconds for 32 MB over Ethernet • 10 Hz BPM data to Memory; • has several hundred DSP slices for digital filtering • Virtex 5 has >90% Memory registers in use – Virtex 6 will give us 5x more. • Digital Front End Used as Cell Controller • calculates fast orbit feedback algorithm for local in 4 microseconds • matrices for up to 90 eigenvectors; • I/O board can be used for fast machine protection • 16 digital input, 12 digital outputs and 4 analog outputs for fast machine protection; • four 100 Mbps copper ports for redundant comm links to the fast and slow power supplies. • Power Supply Controller (PSC) is ready for production • provides redundant 100 Mbps network to all power supplies within one cell. • provides Memory access by Modbus protocol over 100 Mbps Ethernet • dedicated fiber from each Power Supply Control to each Power Supply Interface. • Power Supply Interfaces (PSI) is ready for production • demonstrated < 5 ppm long term stability • takes 10 KHz data for up to 10 seconds for diagnostics • 20 bit DAC (1 ppm resolution), 16 bit ADCs for DCCT

  8. High Level Applications (HLA) • High level applications requirements are identified and being refined • High level application architecture is client/server • based on the EPICS version 4 network protocol, PVAccess • One server provides results to all clients • New data types have been defined for multichannel arrays, multidimensional arrays, images, statistical samples, tables (arbitrary collections). • These are being implemented in PVAccess • Servers are completed that provide: • Model Results • List of process variables based on function and attributes • Synchronous vector of data given a list of process variables. • Other Services are under development. • Developer document for thin clients is being written in conjunction with the physics group. • Standard clients in CSS can be used to display HLA data

  9. Client-Server Architecture for HLA Completed MMLT Client Scripting HLA Client Early Development Being Extended PVAccess/CAC PVAccess/CAC Production HLA Client Control System Studio Ethernet PVAccess/CAC PVAccess / CAC PVAccess/CAC PVAccess/CAC PVAccess/CAC PVAccess PVAccess PVAccess Magnet Conv, Response Matrix, Dispersion, etc…. Multi-Channel Arrays Svr Save/Compare Restore Svr Channel Finder Svr Model Server Lattice Server Middle Layer Servers SQL Elegant/Tracy SQL SQL Serves orbit, magnets, any array of channels RDB IRMIS IRMIS CAS PVA CAS PVA Diag & PS CAS CAS PVA CAS PVA CAS Utilities etc.., PVA PVA Diagnostics RF Power Supplies Vacuum Distributed Front-Ends LS2 Simulation Physical Device Physical Device Physical Device Physical Device Physical Device

  10. IRMIS • Production tools available for • Component type editor • Component editor • Component Browser • Wiring Editor • Control group members have started to enter component types • Subsystem engineering groups have started to enter component data • Subsystem engineering groups have done initial testing of the wiring editor • Rapid prototyping tools are in place to support developing applications • Lattice • Electronic log • Save Compare Restore (SCORE) • Magnet Measurements • Component Inventory and History • Physics group and mechanical group are working with us on these • IRMIS Crawler, which was developed at Argonne, looks at EPICS configuration files and provides data management. • We have no deployed databases or clients so this is not yet in use.

  11. PERL crawler Rapid Prototype • Rapid Prototype Environment: • lattice • cmpnt inventory • cmpnt history • magnet measurements • traveler • elog • pv_meta • service config (alh, ar, score) • logscore • cmpnt channels • PERL: • epics config software • CA clients • history • Data Services Layer: • component types • cmpnt config (installation) • cables, tray partitions DSL

  12. Component applications

  13. Cabling applications

  14. EPICS Extensions • EPICS core extensions • Client specified filtering for rate limiting, dead bands, and sub arrays. • State record primitive to provide modular solution to motion and multistate devices such as valves that need to capture transition times and timeouts. • New modular interface to event generator and event receiver • C++ Implementation of PVAccess servers to serve V3 databases • Control System Studio – User Interface Tools • Adopted CSS for our user interface after evaluation • Redeveloped build environment and had it adopted by the collaboration • Developed a name server to return process variables by function • Developed a channel access package to provide all client functions and time synchronous vectors from an arrays of process variables. • Developed multichannel visualization tools

  15. CSS Tools Adopted - Probe, pvtree

  16. CSS Tools Adopted - Data Browser Plot ‘live’ and historic data over time (combination of striptool and archive viewer)

  17. CSS Tools Adopted - BOY BOY is an Operator Interface (OPI) development and runtime environment.

  18. CSS Tools Adopted - BOY BOY runtime environment/example OPI screens

  19. Developed Tools - ChannelFinder Viewer Used to search for channels by name, properties tags. Sort, filter tag channels

  20. Developed Tools - Multi channel Viewer • Same set of channels • Fig1. sorted by position • Fig2. sorted by name

  21. Subsystem Status • Subsystem Responsibilities • Timing Joe Delong, Jayesh Shah • Diagnostics Yong Hu, Kiman Ha, and Huijuan Xu (Steve Hunt) • Power Supplies Yuke Tian, Shweta Saraf • Vacuum equipment Huijuan Xu • Equipment Protection System David Dudley • Personnel Protection System David Dudley • RF Joe Delong, Michael Davidsaver • Beam Line Control Daron Chabot, Wayne Lewis • Insertion Device Control Daron Chabot, Wayne Lewis • Facility Control Sheng Peng • Network / File Servers Robert Petkus • Physics Application Guobao Shen, Nikolay Malitsky • Preliminary Design Complete for all machine subsystems. Good progress on beam line control. • Prototypes are under development and continue to verify requirements are met. • Final Design will include: • Extended Preliminary design to include: • Final hardware selection • Software packages identified and specified • Complete Component Type definitions in IRMIS • Complete signal counts completed

  22. Subsystem Test Stands Network Design Complete Core switches ordered ($320K) Vacuum Lab Diagnostics Fast Digitizers and cPCI crate Application File SeVacrver Timing Hardware Soft IOCs IRMIS Redundant Servers w/ Raid Disks Radiation Monitor Test Stand PPS Test Stand EPS Test Stand Image Acquisition Test Stand Motion Control Test Stand

  23. Subsystem Standards (1 of 2) • Application Development Environment – Established in Mercurial • Naming Convention • established early by project management • distributed responsibility • Component types and installed components to be documented through IRMIS • Equipment standards (developed with each group): • Timing – established Micro Research Finland as standard • Diagnostics – standard for each class of problem • Vacuum – standard interfaces for serial devices being determined. • Equipment Protection System –Allen-Bradley and Siemens standard for PLCs established and in use for all project PLCs, We integrate PLC data into EPICS • Personnel Protection System – Siemens and Allen-Bradley Safety PLC selected. We implement B chain. • RF – controllers are under development. Not yet integrated. • Turnkey contracts include statements to use the standards as defined in each subsystem by NSLS II.

  24. Subsystem Standards (2 of 2) VME Crates – two vendors that we are evaluating: Elma and Weiner cPCI Crates – under evaluation Soft IOCs – Linux servers – same as used for control room applications. Processors – Motorola and Intel processors being evaluated PLCs – Allen Bradley chosen as standard – putting together standard component list External vendors have Siemens as an option. Timing – Micro Research Finland latest series chosen Camera – Proscilica with GigE interface chosen Fill Pattern – Acqiris chosen. DCCT has GE digitizer under evaluation. Cell controller – First spin operational – Ready for spin 2 – moving to Virtex 6 BPMs – First spin operational – Ready for spin 2 - Libera still a backup plan. Power supplies – in house development I chosen – ready for production. Racks are specified by electronics group Switches – Brocade and Juniper under evaluation Core Switches – Brocade chosen – purchase order out. Motion control – Delta Tau and Galil under consideration. Delta Tau meets all requirements.

  25. Conclusions • The cell controller, power supply controller, and beam position monitor digital hardware is all running • A second spin for the DFE will be completed in February • The PSC and PSI are ready for production. • The Cell controller can support 100 microsecond machine protection if needed • The High Level Physics Application architecture is in place and being used as each service and application is prototyped. • The IRMIS tools are well supported by the developers and have gained acceptance outside of the control group. • Management support is strong to assure success. • An active collaboration is started with FRIB. • Our preliminary designs are complete and final designs are started for all subsystems except beam line controls. • We are ahead of schedule in prototyping all subsystems in order to provide timely decisions on hardware and software standards. • The control team has established critical mass and has very strong momentum.