1 / 28

VITALITY Large Splits

VITALITY Large Splits. Large Splits Axial Condensing fan. Benefits: Split system from 20 to 90 kW Ductable indoor unit Auxiliar heating (elect heater or hot water coil) available Allows ventilation, free cooling available Where to apply / typical market:

elon
Download Presentation

VITALITY Large Splits

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. VITALITYLarge Splits Johnson Controls PowerPoint Guidelines | July 21, 2009

  2. Large Splits Axial Condensing fan Benefits: • Split system from 20 to 90 kW • Ductable indoor unit • Auxiliar heating (elect heater or hot water coil) available • Allows ventilation, free cooling available Where to apply / typical market: • As an universal condensing unit to match with other systems (evaporator of a AHU) • For offices where duct installation is the preferred solution against chiller+FCU or multiple minisplits • Typical installations are anyplace where AHU is fitted, industry, petrol stations

  3. Large Splits Centrifugal Condensing fan Benefits: • Split system from 20 to 90 kW • Ductable indoor unit • Auxiliar heating (elect heater or hot water coil) available • Allows ventilation, free cooling available • Indoor can be installed on top of the outdoor unit (compact solution) Where to apply / typical market: • As an universal condensing unit to match with other systems (evaporator of a AHU) • Indoor Installations in technical room (to prevent from extreme outdoor temps or to install low noise kits or no outdoor inst possible) • For office buildings, supermarkets …

  4. LARGE SPLIT CENTRIFUGAL FAN – VCH Main Advantages / Features • R410A Refrigerant • Improved efficiency and reduced noise level • YKLON V3 board • Designed to service (service valves, improved accessibility) • Vertical or horizontal discharge • 50m pipe length • New options and accessories • Economizer • Return fan • Hot water coil and control (0-10V, 4 stages) Johnson Controls

  5. Stop valves Service valves Large Splits Centrifugal Condensing fan Access to components Johnson Controls

  6. Large Splits Centrifugal Condensing fan • Access to components Electrical box Motor Belt / Pulley TEV’s Sight glass Filter Drier Elec. channel Compressors Cabling Service valves Piping Johnson Controls

  7. Large Splits Centrifugal Condensing fan • Low ambient control (down to – 10°C) Actuator Control Damper Low Ambient regulation * * Not suitable for outdoor application Johnson Controls

  8. Large Splits Axial Condensing fan Main Advantages & Features Vs SOC/SOH + SICH • R410A Refrigerant • Improved efficiency • Quiet operation • Shares same indoor unit as VCH -> VIR • Long pipe run (up to 50m) • New size 20 kW • New PCB YKN2Open (JCI protocol) • New options and accessories • Soft Start Compressor for outdoor unit • LAK as option (before as standard) Johnson Controls

  9. Large Splits Axial Condensing fan • Outdoor Fan: Highefficiency, Lownoiseoperationcondenser fan. Johnson Controls

  10. Large Splits Axial Condensing fan • CompressorSoftStart: Itisonlyneededto do thewiringconnections. It comes automaticallyadjustedfromfactorytotheoptimalpoint • Provides alarm signal in case of: • - Wrong phase sequence • Low voltage • Frequency out of range • Locked rotor • overheating • … Johnson Controls

  11. Large Splits Axial Condensing fan • LAK Condenser fan: FromJonhsonControls, model P215PR, itisdeileved at 26 bar by default. • Needed 1 per circuit. Johnson Controls

  12. Large Splits Axial Condensing fan • LAK Condenser fan: FromJonhsonControls, model P215P, itisdeilevedregulated at 26 bar. Johnson Controls

  13. Large Splits Indoor unit VIR Main Advantages / Features • R410A Refrigerant • High efficiency & reduced noise level • High Static Pressure Available • Designed to service • Vertical or horizontal discharge • Possibility to install on top of condensing unit centrifugal fan • Accessories: • Economizer • Electrical heater • Hot water coil and control (0-10V, 4 stages) • Return fan • High speed drive Johnson Controls

  14. Large Splits Indoor unit VIR • Air filter • G3 filter with handle • Mechanical fastening easy to remove 1 2 Pull Filters connection Johnson Controls

  15. Large Splits Indoor unit VIR • Access to components TEV’s Piping Motor Belt / Pulley Johnson Controls

  16. Large Splits Indoor unit VIR • Access to components TEV’s Hot water valve & Actuator Piping Motor Belt / Pulley Johnson Controls

  17. Large Splits Indoor unit VIR • Access to components TEV’s Safety thermostats Piping Electrical box Motor Belt / Pulley Johnson Controls

  18. Large Splits Indoor unit VIR • Economizer can be assembled alone with the unit • Return fan needs to be ordered always with return fan • Economizer & return fan Johnson Controls

  19. Jumper S2 give priority heat stages: - jumper OFF: Heat pump compressors 1st and 2nd heat stage • - jumper ON: Hot water coil 1st heat stage Large Splits Indoor unit VIR • Hot water coil • Modulating valve with 4 stages:- Stage 1: Supply air 30°C - Stage 2: Supply air 40°C - Stage 3: Supply air 45°C - Stage 4: Supply air 50°C & Hot water coil minimum supply air temperature 15°C • Anti freeze protection:- If water temperature < 3°C, water pump and water valve are activated open- Antifreeze protection stop when water > 6°C Johnson Controls

  20. Large Splits Indoor unit VIR • Electrical heater • Box tap with ventilating windows • Contactor in 24V • All heater inside the VIR, after evaporator coil (between fans phased out) • The heater board to be installed on site in the outdoor unit • 2 x 0,75 mm2 cable to protect against EMC uncertainty • All components at the opposite of refrigerating tubing for easy service Johnson Controls

  21. Large Splits Indoor unit VIR • Indoor soft start Johnson Controls

  22. Large Splits Indoor unit VIR • Standard & High Speed Drive VIR’s Minimum Airflow Nominal Airflow Maximum Airflow Indoor fan power input Available static pressure Johnson Controls

  23. Large Splits Indoor unit VIR • Vertical discharge VIR’s Johnson Controls

  24. LargeSplitsCompetitorsBenchmark

  25. Large Splits Competitor Benchmark Chart comparison – EER Vs Capacity Johnson Controls

  26. Large Splits Competitor Benchmark Chart comparison – COP Vs Capacity Johnson Controls

  27. Large Splits Competitor Benchmark Chart comparison – Sound Power (LwA) Vs Capacity Johnson Controls

  28. THANKS FOR YOUR ATTENTION! Johnson Controls PowerPoint Guidelines | July 21, 2009