EZ Positioning with SINAMICS S120 Agenda. Starter Basic Sinamics Drive Setup Insert Drive (CU310 or CU320) Auto Configure CU and Drive-CLIQ Devices Starter Offline Configuration Drive Configuration Wizard Telegram Setup for EZ _EPOS Block Check S7 Hardware Configuration
E N D
Starter Basic Sinamics Drive Setup Insert Drive (CU310 or CU320) Auto Configure CU and Drive-CLIQ Devices Starter Offline Configuration Drive Configuration Wizard Telegram Setup for EZ _EPOS Block Check S7 Hardware Configuration Execute EZ_EPOS Script File Copy from Example Project Execute and Save Project Download to Sinamics Step7 Simatic Manager Programming Copy Needed blocks to new Program Setup FB120 in new Program Edit Symbol Table Save and Download S7 Project Test EPOS Application on Demo Run through all EPOS Modes with S7 PLC and S120 Demo Sinamics EZ EPOS Agenda
Open S7 and Select File / New Select new Name for Project and Press OK Start New Project with S7 Simatic Manager
Right Click on New Project and insert new Object Choose S7 300 Station New Station inserted --Note Hardware Icon Insert S7 300 Simatic Station
Start Hardware Configuration Click on Hardware Icon and Open HW Configuration • Open Hardware Catalogue • Insert S7 300 Rack, Power Supply, and CPU
Add Sinamics S120 in Hardware Configuration Drag the drive on to the Profibus Network • Choose Node Address 4 • Select Present Firmware Version (2.5) • Choose Telegram Type None
Save and Close Hardware Configuration Press Save an Compile Button • Hardware Configuration should Save and Compile • Correct any errors if they occur Exit the Hardware Configuration • HW Config must not be Open for Next Section!
EZ Positioning with SINAMICS S120Basic Starter Online Commissioning
Open Starter by Motor Icon for Sinamics Open Starter Program & Go Online • Go Online with Starter –Use • Do not Upload to the PG!
Right Click On CU310 (or CU320) and Choose… Target Device / Restore Factory Settings Default CU310 or CU320 • Check the Box – Save Factory Settings to ROM • Power Cycle Drive after RAM to ROM Completed
Complete Auto Configuration • Select Auto Configuration and Start Auto Configuration • Choose Control type for Motor type • Close after Initialization
Starter Offline Configuration Go Offline with the Sinamics Select Configuration under the Device Folders • This Configuration is under the Drive Object Used • Click On Configure DDS to Parameterize Drive Settings
Thank you very much Name: Carl Owens & Kevin Wu Department: Production Machines Address: 5300 Triangle Parkway, Suite 100 Norcross, GA 30092 Mail: carl.owens@siemens.com wu.kevin@siemens.com
EZ Positioning with SINAMICS S120Basic Starter Offline Commissioning
Open Starter by Motor Icon for Sinamics Open Starter Program & Go Offline Go Offline with Starter –Use
From the Drive to be Commissioned Choose… Configuration Open DDS (Drive Data Set) • Choose Configure DDS… • Offline Configuration Wizard is Opened
Control Structure Setup • Select Speed Control with Encoder • Use Function Modules when Needed • For EPOS Basic Positioner is Needed • Next, Select Continue
Power Unit Configuration Power Unit Data Up-read in Auto Configuration (Drive-CLIQ) • Confirm Device type is Correct via Part label • Select Continue for next Configuration Screen
Motor Configuration Motor Data Up-read in Auto Configuration (Drive-CLIQ) ** • **If Motor is a Drive-CLIQ Motor • Non Drive-CLIQ Motors can be Selected from List • Third Party Motors can have data entered
Holding Brake Configuration Motor Data Up-read in Auto Configuration (Drive-CLIQ) ** • **If Motor is a Drive-CLIQ Motor • Non Drive-CLIQ Motors Check Motor Name Plate • DEMO drive do not Use Holding Brakes
Encoder Configuration Encoder Data Up-read in Auto Configuration (Drive-CLIQ) ** • **If Encoder / Motor is a Drive-CLIQ Motor • Siemens and Third Party Encoders can be Parameterized • Note Encoder 1 is from Motor Encoder
Encoder Data Configuration Encoder Data Up-read in Auto Configuration (Drive-CLIQ) ** • **If Encoder / Motor is a Drive-CLIQ Motor • Siemens and Third Party Encoders can be Parameterized • Note Encoder 1 is from Motor Encoder
EPOS Only - Encoder Used for Position Sensing Select Encoder Used • Note that Encoder_4 refers to Device number 4 • Usually Motor Encoder used for Position Sensing
EPOS Only – Mechanics Parameterize Gearing and Resolution • Modulo Axis can be programmed if need • This is only used in EPOS – For Basic Positioner • Load Revolutions = Gearing • Lu / Load is resolution • Default for testing in DEMO
EPOS Only – Mechanics Parameterize Gearing and Resolution • Modulo Axis can be programmed • Load Revolutions = Gearing • Load Revolutions = Gearing • Lu / Load is resolution • Use Default for testing in DEMO
Profibus Telegram type Choose Free Telegram with BICO • The Profibus Telegram will be Configured Later • Free Telegram allows Custom Telegrams • Script Files will be used to Setup Telegram Mapping
Summary Data Acceptance Review data and Click Finish if Complete • After Completing DDS Wizard “Save and Compile” • DDS Wizard Data is now Complete
Profibus Telegram Configuration • From the Drive to be Commissioned Choose… • Configuration • Use Up – Down Buttons to Move Drive Objects • CU is 1st and Drive (S) should be in Preceding Order • S7 Hardware Configuration Should be Closed!
Profibus Telegram Configuration Select Word Length For Telegrams • CU Telegram not needed for Demo Word Length For Telegrams • EZ_EPOS uses 10 words IN and 10 Words Out • EZ_APC_SPEED uses 10 Words IN and 10 Words Out • EZ_Basic_SPEED uses 6 Words IN and 6 Words Out
Profibus Telegram Configuration Select Transfer to HW Config • CU Telegram will be sent to the S7 Hardware Config. • Select Yes to transfer
Profibus Telegram Configuration Telegram has Successfully been Transferred • Note Blue Check Boxes Save and Compile Program before Proceeding • Save and Compile Using Starter
Copy Script file from Example Program Open Starter Program in EZ_EPOS Example • Close Example Program’s Starter and go to new Program
Right Click On Drive to be Commissioned Expert / Insert Script Folder Create Script Folder in New Program Paste EPOS Script in Script Folder
Click On EPOS Script The Script Editor Opens Open EPOS Script in New Project • Click inside the Script Editor area • The Script Editor Buttons appear on the Task Bar
Click On the Accept and Execute Button The script File parameterizes the drive for EPOS All the Drive Parameters needed by FB120 are Complete Save and Compile the Starter Program The Program is now Ready for Download Accept and Execute the Script
Go Online with Starter to the Drive Choose Download to the Drive Choose RAM to ROM Drive is now ready for Operation Download to the Drive
EZ Positioning with SINAMICS S120S7 Simatic Manager Programming
Open S7 Program & S7 Hardware • Open New Sinamics S7 Project • And Open Hardware Configuration • To Confirm Configuration of Telegram
Verify Telegram Configuration • Highlight the Profibus Card and View the Telegram • Telegram will be “User Defined” • Length should be 10 words (20 bytes)
Download Configuration to PLC • Save and Compile HW Configuration • Download Configuration to PLC
Download Configuration to PLC • Follow S7 Sequence to Download Hardware Config • Select Target Module (If Multiple PLCs) • Restart PLC after Download • PLCs LED will still show Fault
Copy Blocks to New S7 Program • Open the Example Program and Copy Relevant Blocks • Task Bar – Use Window / Split Horizontally
Copy Blocks to New S7 Program • Open the Example Program and Copy Relevant Blocks • See Example Below for Copying Blocks • Paste Blocks in new S7 Program • VAR (Variable Table) can be copied • VAR may need editing if Instance DB # Changes • Instance DB will be Created in Later Step • Copy Relevant Profibus Communication Blocks • OB82, OB86, and OB122 • SFC14 and SFC15 are PLC System Function Blocks
Insert FC (Function Call) for Drive(s) • Right Click on S7 Blocks Folder and Insert a FC • Edit Symbolic Name and Comments
Open New FC and Insert Drive FB • Open FC and Choose Drive FB from Catalogue • Note Catalogue Icon Highlighted on Task Bar • Insert a network and Drag FB120 on to Network Add text
Insert Instance DB in Drive FB • DB number is Entered to Generate Instance DB • Enter DB120 in “????” to test with Variable table included • Multiple FB120s with Specific DBs can be used
Parameterize Function Block • Nominal RPM and Hex address from Drive • Use Nominal Speed for Demo or Machine • Address is same as in Hardware Config-Profibus for Drive • Address is Hex value and not decimal value • Save FC
Insert FC in OB1 • Open OB1 Block • Save Program in OB1 After Inserting FC