1 / 11

FRONT VIEW

PMD Layout and Design. CPV. PreShower. Two planes: Veto + PreShower Gas detector with hexagonal cells Cell cross section: 0.22 cm 2 Cell depth: 0.5 cm Total No. of channels: 169,344 Distance from vertex: 355cm h Coverage: 2.3 – 3.5 Area of the detector: 1.8m 2

erna
Download Presentation

FRONT VIEW

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PMD Layout and Design CPV PreShower • Two planes: Veto + PreShower • Gas detector with hexagonal cells • Cell cross section: 0.22 cm2 • Cell depth: 0.5 cm • Total No. of channels: 169,344 • Distance from vertex: 355cm • h Coverage: 2.3 – 3.5 • Area of the detector: 1.8m2 • Ave. Occ: 13% for CPV & 28% for PMD • Photon counting Efficiency: 64% & • purity: 60% FRONT VIEW DCS WORKSHOP

  2. PMD Front-End Electronics FEE Board Mounting and Cooling 4 chip MCM board with MANAS-16 (similar to that of station 3-4-5 of Dimuon Tracking) DCS WORKSHOP

  3. DCS WORKSHOP

  4. PMD Readout Chambers FEE Gas High Voltage Low Voltage Cooling Flow HV Crate Air Flow LV Crate Temp. PMD Control System The Control System of PMD will consist of following subsystems: 1. High Voltage System 2. Gas System 3. FEE - Low Voltage System - Cooling System DCS WORKSHOP

  5. One Power Supply Line (Current ‘N*I’ in line) ‘N’ Power Supply Lines (Current ‘I’ in each Line) LV PS Distribution Box Read out ~50m FEE FEE FEE FEE Monitoring No. of LV Chains : 180 Voltage : +/- 2.75V, +5V Current : 5A/Chain Model : PL500 from Wiener, 3U size Control ‘On/Off’ CAN Filed Bus Interlock : With cooling Alarms : depending on current limit / channel Schematic of LV Control System DCS WORKSHOP

  6. One Power Supply Line (Current ‘N*I’ in line) ‘N’ Power Supply Lines (Current ‘I’ in each Line) HV PS Distribution Box ~50m SM SM SM SM Monitoring No. of HV Chains : 60 Voltage : - 2000V Current : 100 uA/Channel Model : ISEG or SY1527 Control ‘On/Off’ CAN Filed Bus Interlock : With Gas sub system Alarms : depends on currents/channel Schematic of HV Control System DCS WORKSHOP

  7. PMD Cooling Setup to find out if Air Cooling is adequate for the PMD-FEE. DCS WORKSHOP

  8. Effectiveness of forced air cooling can be seen here. DCS WORKSHOP

  9. Gas Sub System Gas ratio : Ar : Co2 ( Ratio 70: 30) Monitoring : Required Interlock : With HV System Cooling Sub System Control Parameters : - Air flow - Temperature, 60 points wit pt100 Interlock and Alarms : - Interlock with LV Power supply System - Alarms if Temperature is not within limit Alignment : - Few monitoring places DCS WORKSHOP

  10. ALICE PMD DCS WORKSHOP

  11. DCS WORKSHOP