An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Understanding Piezo based Sensors for an acoustic neutrino detector ARENA-06, Newcastle, UK Christopher Naumann,Universität Erlangen-Nürnberg

  2. Acoustic Detection with the ANTARES Telescope re-fit several ANTARES storeys with acoustics hardware (sensors and DAQ) replace optical sensors with acoustic sensors (schematic) • Aims: • design studies for an acoustic neutrino detector in the deep sea • thorough studies of the acoustic environment in the deep sea: Correlations of the acoustic background over several length scales (<1m up to > 100m)

  3. Aim: Acoustic Sensors • Basic Design of Sensors for the ANTARES acoustics • Sensor = piezo element (disc and/or tube) + pre-amplifier • either encapsulated in polyurethane = > "hydrophone" • or coupled to ANTARES glass sphere = > "acoustic module" internalpre-amplifier cable ANTARES glass sphere 17" (42cm) piezo tube PU coating piezo sensors + pre-amplifiers Signal response and noise characteristics of sensors depend on piezo element  try to build model

  4. Electro-Mechanical Equivalent Circuit A F h • Piezo  couples mechanical and electrical properties • analogy between forced mechanical and electrical oscillation •  mechanical properties of piezo expressible by equivalent electrical properties: LRC p (Cp = electrical capacity between electrodes)  = electromechanical coupling constant (depends on material) mechanical oscillator electrical oscillator knowledge of equivalent circuit  simple model of piezo

  5. Equivalent Properties (1): Measurement • get all properties from single impedance measurement on piezo element: • apply gaussian signal on voltage divider made of piezo and suitable capacitor • measure signal over capacitor • calculate fourier transforms of signals • from these calculate impedance spectrum of piezo element equiv. circuit with n parallel LRC branches Impedance (k)0.1 1 10 100 Anti-Resonance(Z maximal) Resonance(Z minimal) Fit with Li, Ri and Ci as parameters 10kHz 100kHz 1MHz possible for free and coated or attached piezos

  6. Equivalent Properties (2): Coupling 74mH 666 25pF 74mH 3043 23pF Properties of piezo elements depend on coupling to environment: free piezo: strong resonances • coupling limits movement damping  R increases • resonances are weakened - other properties unchanged - coupled: resonances suppressed Impedance (k)0.1 1 10 100 10kHz 100kHz 1MHzFrequency free piezo piezo in sphere sensitivity of piezo element can now be modelled... significant increase of equivalent ohmic resistance  damping

  7. Sensitivity (1): Derivation sensitivity resonance 10 10 relat. sensitivity 1 1 0.1 0.1 static sensitivity 0.01 0.01 1kHz 10kHz 100kHz 1MHz • piezoelectric effect: pressure  voltage a) ideal piezo converter: U / pindependent of frequency  b) real piezo converter: LRC branches and Cp as voltage divider  Ua / p frequency dependent(for 0 constant  static case) "pressure signal" LRC Cp Ua electrodes real piezo converter, n=1 generalised n > 1 6 LRC branches 1kHz 10kHz 100kHz 1MHz

  8. Sensitivity (2): Comparison sensor signal generator+ oscilloscope calibrated transducer • From Impedance get equiv. parameters  sensitivity prediction • Measurement of Sensitivity directly on complete sensor in water tank example: piezo coupled to tank wall -180 Points: MeasurementLine: Prediction sensitivity dB re 1V/µPa -190 data sheet: -192dB=.25mV/Pa -200 10 20 30 40 50 60 70 80 90kHz good agreement between prediction and measurement !

  9. Sensitivity Measurement - Principles frequency domain voltage pulse sent dB (V/V) amplitude (V) transfer spectrum (raw) pulse received fourier transform and divide correct for distance and sender time(µs) • Calibration Chain: • Cross-calibrate transducers using identical pair • calibrate receivers against transducer • can get complete spectrum from onlyone measurement per sensor device ! dBre 1V/µPa corrected sensitivity log frequency (kHz)

  10. Device Calibration – Examples commercial hydrophone with pre-amp (HTI) piezo resonance measurement: -156.7dBre(V/µPa)(=14.6mV/Pa) data sheet: -156dBre(V/µPa) • done for commercial hydrophones (cross-check!) and self-made sensors Acoustic Module (Piezo in Sphere) piezo resonances “plateau” at -120dBre(V/µPa) amplifier cut-off ~ -120dBre(V/µPa)(=1 V/Pa) between 10 and 50kHz 10kHz 100kHz can also invert this process to predict signal shapes...

  11. Prediction of Signal Response raw signal signal response raw signal 2-res. piezo FT log PSD [a.u.] amplitude [a.u.] FT-1 0 100 200 300 400 500 µs 100 200 300 400 500kHz Knowledge of system transfer function allows calculation of signal response: • signal response R(t) = raw signal S(t) convoluted with impulse response I(t) • Thus, calculate signal response by multiplication in fourier domain and subsequent re-transformation into the time domain fourier transform

  12. Application: Response of Complex System example: BIP signal as seen by commercial hydrophone ? a.u. predicted predicted measured sensitivity measured sensitivity impulse response(calc.) measured  FT model fit (3 resonances) 400µs apply this knowledge of piezo response also to complex sensor systems: • measure system sensitivity (absolute value only ?) • model piezo response + amplifier characteristics • fit model to measurement: •  get full (i.e. complex) transfer function • predict signal shapes => simulate signals and noise !

  13. Model Predictions (2) – Piezo Elongation • inverse piezoelectric effect: applied voltage U = > elongation x (important e.g. for acoustic senders) coupling: current <-> velocity: displacement proportional to integral over voltage for sine signal, frequency : =displacement averaged over face of piezo applicable to arbitrary signals by fourier analysis see Karsten's talk tomorrow behaviour for 0: static casex=U/s

  14. Noise acoustic back-ground in lab -80 Piezo+Amp (measured) -90 PSD [dB re 1V/Hz] -100 op amp piezo element -110 50kHz 100kHz 150kHz • Important in addition to sensitivity: intrinsic noise of sensors = noise of piezo element + amplifier • intrinsic noise of piezo: thermal movement equivalent to thermal (Nyquist) noise of real part of piezo impedance • amplifier noise from OP amps (active) and resistors (passive) noise spectral density (PSD) close to resonances, piezo dominates, below amplifier example: acoustic module sensitivity ca.-115 dB re 1V / µPa=1.8 V / Pa • guidelines for amplifier design • S/N prediction

  15. Conclusions and Outlook • Achievements: • easy description of piezo sensors by electromechanical equivalent properties possible • Acquisition of equivalent parameters by impedance measurement (also for coupled or coated piezo elements) • very good agreement between model predictions and measurements for sensitivity, displacement and noise • possibility to model signal response • Outlook: • use this knowledge to design and build acoustic storeys for ANTARES for operation in the deep sea ! • do extensive simulation / reconstruction studies using realistic system response Thank you for your attention !

  16. THE END