1 / 94

Fire Hose, Nozzles, Streams, and Foam

Fire Hose, Nozzles, Streams, and Foam. 16. Objectives (1 of 3). Describe how to prevent water hammers. Describe how a hose is constructed. Describe the types of hoses used in the fire service. Describe how to clean and maintain a hose. Describe how to inspect a hose.

erucker
Download Presentation

Fire Hose, Nozzles, Streams, and Foam

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Fire Hose, Nozzles, Streams, and Foam

  2. 16 Objectives (1 of 3) • Describe how to prevent water hammers. • Describe how a hose is constructed. • Describe the types of hoses used in the fire service. • Describe how to clean and maintain a hose. • Describe how to inspect a hose. • Describe how to note a defective hose.

  3. 16 Objectives (2 of 3) • Describe how to roll a hose. • Describe how to lay a supply line. • Describe how to load a hose. • Describe how to connect a hose to a water supply. • Describe how to carry and advance a hose.

  4. 16 Objectives (3 of 3) • Describe the types and designs of nozzles. • Describe pressure effects and flow capabilities of nozzles. • Describe how foam works. • List the types of foam. • Describe how to make foam. • Describe how to apply foam.

  5. 16 Fire Hydraulics • Deal with properties of energy, pressure, and water flow as related to fire suppression.

  6. 16 Flow • Volume of water that is being moved • Measured in gallons per minute (gpm) • Metric measured in liters per minute (lpm)

  7. 16 Pressure • Amount of energy in a body or stream of water • Measured in pounds per square inch (psi) • Metric measured in kilopascals (kPa) • Required to push water through a hose or to a higher level • Pumps usually provide the pressure.

  8. 16 Friction Loss • Loss of pressure as water moves through a pipe or hose • Loss represents the energy required to push the water. • Greater flow in same hose, greater friction loss • Smaller hose with same flow, greater friction loss • All else equal, loss proportional to distance

  9. 16 Elevation Pressure • Elevation affects water pressure. • Elevated water tanks supply pressure to pipes due to elevation. • Difference between nozzle elevation and engine elevation affects pressure. • Hoses laid downhill have greater pressure. • Hoses laid up stairs will have less pressure.

  10. 16 Water Hammer • Surge in pressure caused by sudden stop in the flow of water • Shock wave is transmitted back through the hose. • Can damage hose, couplings, and plumbing • To prevent, open and close valves slowly.

  11. 16 Functions of Fire Hoses • Attack hose • Carries water from engine to the nozzle • Carries water from engine to master streams • Carries water to standpipe and sprinkler systems • Supply hose • Carries water to the engine • May come from a hydrant or another engine • Carries large quantities at lower pressures

  12. 16 Sizes of Hose(1 of 3) • Small Diameter Hose • 1" to 2 " in diameter • Used as attack lines • Each section is usually 50' long

  13. 16 Sizes of Hose (2 of 3) • Medium Diameter Hose • 2 1/2" or 3" in diameter • Used as attack line or supply line • large handlines usually use 2 1/2“. • master stream and fire department connections often use 3" hose. • Each section is usually 50' long.

  14. 16 Sizes of Hose(3 of 3) • Large Diameter Hose • 3 1/2" or 6" in diameter • Standard diameter is 4" or 5“. • Standard length is 50' or 100' long.

  15. 16 Pressure Testing • Attack hose • Tested annually • Tested to 300 psi • Designed for use up to 275 psi • Supply hose • Tested annually • Tested to 200 psi • Designed for use up to 185 psi

  16. 16 Hose Construction(1 of 2) • Fire hose constructed of inner waterproof liner and one or two outer layers • Outer layers • Provide strength for high pressures • Made from synthetic fibers • Provide some abrasion protection • Can be double jacket hose • Can be rubber-jacket hose

  17. 16 Hose Construction(2 of 2) Inner waterproof liner • Prevents water leakage • Provides smooth surface to reduce friction • Usually made of • synthetic rubber compound • thin flexible membrane • Attached to outer covering

  18. 16 Hose Couplings • Used to connect individual lengths of hose • Used to connect hose to hydrants, valves, nozzles, and fittings • Two types • Threaded • Nonthreaded (Storz-type)

  19. 16 Threaded Couplings(1 of 2) • Used on most hose up to 3" • A set consists of male and female couplings. • Male threads are on the outside. • Female threads are on the inside. • Female couplings swivel. • Fire hose has a male on one end and a female on the other.

  20. 16 Threaded Couplings(2 of 2) • Higbee indicators indicate proper thread alignment. • Female couplings have a gasket to prevent leaks and require periodic replacement.

  21. 16 Storz-type Couplings • Has neither male nor female ends • Most often used in large diameter hose • Couplings are mated face-to-face and turned clockwise one third. • Adapters are used to connect to threaded couplings.

  22. 16 Attack Hose(1 of 4) • 1 1/2" and 1 3/4" • Most common attack line • Both use 1 1/2" couplings • Can be operated by one fire fighter • Most common preconnect lengths of 150' to 350' • 1 1/2" generally flows 60-125 gpm • 1 3/4" generally flows 120-180 gpm

  23. 16 Attack Hose(2 of 4) • 2 1/2" hose • Used to attack larger fires • Generally flows about 250 gpm • Takes at least two fire fighters inside a building • Weight per 50' section • Without water, weighs 30 pounds • With water, weighs about 200 pounds • Can flow up to 350 gpm

  24. 16 Attack Hose(3 of 4) • Booster hose • Usually carried on a hose reel with 150' to 200’ • Made of rubber with steel wire to give shape • Can be advanced by one fire fighter • 1" line flows 40-50 gpm • Used for small outdoor fires and trash dumpsters

  25. 16 Attack Hose(4 of 4) • Forestry hose • Typically 1" or 1 1/2" • Used for grass, brush, or forestry fires • Extremely maneuverable

  26. 16 Supply Hose • Used to supply attack engine • Ranges from 2 1/2" to 6" • Large diameter is more efficient than 2 1/2" • Two types • Soft suction • Hard suction

  27. 16 Types of Damage to Hose(1 of 4) • Mechanical • Abrasion from road surfaces • Broken glass and sharp objects • Abrasion from hose reloaded dirty • Vehicles running over it • Couplings being damaged • Couplings being dragged

  28. 16 Types of Damage to Hose(2 of 4) • Heat and cold • Direct contact from fire • Burning coals and embers • Hot surfaces such as heating units and exhaust pipes • Freezing can rupture inner liner and break outer liner fibers. • Lines may be frozen or encased in ice.

  29. 16 Types of Damage to Hose(3 of 4) • Chemicals • Encountered at many incidents, including vehicle fires and accidents • Wash hose as soon as possible with approved detergent.

  30. 16 Types of Damage to Hose(4 of 4) • Mildew • Grows on fabrics in warm, moist conditions • Feeds on natural fibers and causes the hose to rot • Modern hose has synthetic fibers and resists mildew. • Rubber-covered hose fibers are protected from mildew.

  31. 16 Cleaning, Maintaining, and Inspecting Hose • Cleaning and maintaining hose • Clean contaminated hose • Hose inspections • Perform quarterly and after each use • Hose records • Written history of each length of hose

  32. 16 Hose Appliances(1 of 10) • Wyes • Split the stream into two hose streams • Commonly split a 2 1/2" hose into two 1 1/2" • Gated wyes have two quarter turn valves.

  33. 16 Hose Appliances (2 of 10) • Water thief • Combines two hose lines into one • Has a 2 1/2" inlet, a 2 1/2" outlet, and two 1 1/2" outlets

  34. 16 Hose Appliances (3 of 10) • Siamese • Combines two hose lines into one • Has two female inlets and one male outlet • Often used on engine outlets, master streams, and fire department connections

  35. 16 Hose Appliances(4 of 10) • Adaptors • Used to connect same size hoses but with dissimilar threads • Are double-female or double-male

  36. 16 Hose Appliances(5 of 10) • Reducers • Used to attach smaller hoses to larger hoses • Commonly used to reduce a 2 1/2" hose to a 1 1/2" hose

  37. 16 Hose Appliances(6 of 10) • Hose jacket • Used to stop a leaking section of hose • Consists of a split metal cylinder that fits tightly over the hose

  38. 16 Hose Appliances(7 of 10) • Hose roller • Used to protect a line being hoisted over an edge • Prevents chafing and kinking

  39. 16 Hose Appliances(8 of 10) • Hose clamp • Used to temporarily stop the flow of water in a hose: • so the hydrant can be opened • that has burst

  40. 16 Hose Appliances(9 of 10) • Master stream devices • Large capacity nozzles supplied by two or more lines • Include deck guns and portable nozzles

  41. 16 Hose Appliances(10 of 10) • Valves • Control the flow of water through hose or pipe • Must be opened and closed slowly

  42. 16 Types of Valves(1 of 2) • Ball valves • Used on nozzles, gated wyes, and engine discharges • Consist of a ball with a hole in it • When hole is in-line with inlet and outlet, water flows. • When ball is rotated, flow shuts off.

  43. 16 Types of Valves(2 of 2) • Gate valves • Used on hydrants and sprinklers • Rotating spindle causes gate to move across opening • Butterfly valves • Used on large pump intake • Opened by rotating handle one-quarter turn

  44. 16 Hose Rolls • Hose roll is an efficient way to transport a single section of fire hose. • Hose can be rolled in many different ways, depending on how it will be used.

  45. 16 Supply Hose Evolutions(1 of 4) • Forward hose lay • Allows first engine to establish a water supply without assistance • Places the attack engine close to the fire • Can be used with medium or large diameter hose

  46. 16 Supply Hose Evolutions(2 of 4) • Four-way hydrant valve • Used when a supply engine may be needed at the hydrant • When four-way is placed on the hydrant, water initially flows. • A second engine can then hook to the four-way and boost pressure to the supply hose.

  47. 16 Supply Hose Evolutions(3 of 4) • Reverse hose lay • Hose is laid from the fire to the hydrant. • Often used when attack engines begin attack without a supply line • Later arriving company stops at the attack engine and lays line to the hydrant.

  48. 16 Supply Hose Evolutions(4 of 4) • Split hose lay • Performed by two engines • Used when hose must be laid from two directions • Requires coordination by two-way radio

  49. 16 Loading Supply Hose (1 of 4) • Hose can be loaded in different ways, depending on the way the hose is planned to be laid out. • Learn the specific hose loads used by your department.

  50. 16 Loading Supply Hose (2 of 4) • Flat hose load • Limits wear on hose edges • Used with single and split hose beds

More Related