Part 5. Nasser Faleh Al-Ajmi 205114238 Cooler E-107 distillation column. Heat exchanger. Sample calculation Specification sheet. Sample calculation. Calculating the heating load  Qh = mh *Cp * (T1-T2)hot Calculate cooling flow rate  F cooling = Q / (cp*ΔT) cold

etoile
Download Presentation

Part 5

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Part 5 Nasser Faleh Al-Ajmi 205114238 Cooler E-107 distillation column

  2. Heat exchanger • Sample calculation • Specification sheet

  3. Sample calculation • Calculating the heating load  Qh = mh *Cp * (T1-T2)hot • Calculate cooling flow rate  Fcooling = Q / (cp*ΔT) cold • Temperature correction Factor calculation:- assume two tubes and for shells and calculate R , S and ∆Tlm R = (T1-T2) / (t2-t1) and S = (t2-t1) / (T1-t1)  Ft ∆Tlm =(T1-t2)-(T2-t1) / ln((T1-t2)/(T2-t1))  ∆Tm = Ft * ∆Tlm • Calculating Provisional area A=Q/U*∆Tm ((U is assumed)) • Calculating the no. of tubes Nt= (provisional area/area of one tube) • Calculating the shell diameter Ds=Db+Bundle diametrical clearance Db=Db = (do)*( Nt / K1)^ (1/n1)  ((k1 and n1 are constants))

  4. Total flow area = tubes per pass * cross sectional area • mass velocity = mass flow rate / total flow area • linear velosity (ut ) = mass velosity / density • Calculate inside coefficient for water hi = (4200* (1.35+0.02t)* ut0.8)/(di0.2) ((di tube inside diameter))