MegaTron and MegaTronSS Water Treatment’s Most User Friendly Web Capable Controllers. Menu and Keypad. User friendly ATM menu 16 lines of information 20 button keypad Set everything from keypad. System Approach. MegaTron “system” approach for 1 to 4 independent systems
E N D
MegaTron and MegaTronSS Water Treatment’s Most User Friendly Web Capable Controllers
Menu and Keypad • User friendly ATM menu • 16 lines of information • 20 button keypad • Set everything from keypad
System Approach • MegaTron “system” approach for 1 to 4 independent systems • MegaTron SS for single system control • Conductivity • Temperature • pH • ORP • 2 water meter inputs • Flow switch input • 5 additional digital inputs • Up to 5 chemical feed timers • Make-up conductivity (on full size MegaTron)
Conductivity Control • 1 Point Calibration • Bleed Limit Timer • Cycles Control with Make-up Conductivity • Boiler sampling: Continuous, Timed, Sample and Hold
ORP and pH • Set point control including individually set alarms and limit timers. • ORP interlocked with a 28-day timer. • pH feed interrupted by other chemical feed timers. • LSI or RSI values displayed.
Chem Feed Timers • Pulse Timer with Accumulator • Percent Timer • Post Bleed % Timer with Limit • Limit Timer • 28-day Timer
Auxiliary Flow Meter Inputs • Auxiliary flow meter inputs are available to track various flow meter devices like the FloTracker in a metering pump’s discharge line. • Historically track chemical or water usage with low level alarms, no flow alarms to notify of loss prime or no bleed off. • Maintain a set PPM for chemical feed by tracking chemical cycles of concentration, make-up water and chemical addition.
Relay Flexibility • The main box holds up to 10 relays and the controller can control up to 20 relays with 11-20 housed in additional boxes. • What activates each relay can be defined by the user from all of the available control functions on the unit. This means you can have pH monitoring but not have a relay assigned to it. • Multiple functions can be set to activate a relay or force it off, allowing for special control logic.
Service Notepad Each of the up to 4 systems have 10 Service Notepad items for storing user entered data such as testing results that can have a user defined name, number range, unit of measure, high alarm, low alarm and time interval alarm for the next expected manually enter data. The Service Notepad can be used to enter manually tested readings like chemical residual, raw water chemistry, hand held tester readings into the MegaTron. The MegaTron will then keep a record of them for history reporting and alarming.
Water Meter Inputs • Each system card can have 2 water meter inputs. Each will store the hourly average for the past 24 hours, the daily average for the past 60 days reviewable at the unit via the onboard history plus have a running total. • Systems with two active water meter inputs can calculate evaporation with that value also stored in history. • The Units of Measure can be set for Gallons per Contact or Pulses per Gallon allowing for easy configuration for paddle wheel or contacting head meters.
4-20 mA • MegaTron units can have up to eight 4-20mA inputs and MegaTronSS two. Each will have a set point, high alarm and low alarm that could drive a relay. These can all have a user defined unit of measure, number range and name. • MegaTron can have up to six 4-20mA outputs, MegaTronSS three with the user selecting the source from all analog inputs (probes or 4-20mA inputs).
Digital Inputs • 1 Flow Switch input per system card. Choose activation (open / closed), limit probe alarm outputs to only when system has flow and select if timers can run with or without flow. • 5 Digital Inputs can be given a custom name and can activate a relay.
Customization Customers can put in custom names for: • Unit • Systems • Relays • Digital Inputs • Notepad Items • 4-20 mA Inputs
On Screen History See history graphs or logs on screen: • Probe Inputs • Water Meters • Daily Evaporation • Alarm Activation • Relay Activation • Keypad Activity
WebAdvantage and the World Wide Web Keep You in Constant Contact • 128 Bit Encryption Server Security • Back-up Assured History Storage • No Proprietary Software to Load • Log in From Any Computer with Internet Access • Email Notification of Alarm Events
Web Connections Options • Ethernet card with a CAT 5 cable for static or DHCP internet connection. • External cellular router connects back to the controller’s Ethernet card. • Built-in phone modem for dial-up Internet provider (ISP) like EarthLink and a phone line. • BACnet • MODbus
Web Based Remote Monitoring • One Step Connection • View Current Readings • Change Settings • Manage Users • History Graphs and Logs • Create Custom Reports • Set-up Auto Reporting
One Step Connection • Use any Computer with Internet Access • Summary Page Review • Pick From All of Your Units with One Connection
Check Readings / Change Settings • Review Current Conditions • Change Any Setting • Enter Notepad or Service Report Data
Manager Users • Set-up Access to Controllers • Manage Access Levels • Manage Alarm Email Notifications
LXF Integration • T3-Web Reports • Activate our exporting • PIN number • Daily data transfer • Instrument data displayed
History and Auto Reporting • Create Custom Reports • Establish Auto Report Intervals • View Any Data
MegaTron and MegaTronSS Water Treatment’s Most User Friendly Web Capable Controllers Any Questions?