“Understanding AXI Acquisition Techniques and Image Quality” Michael J Smith Michael.J.Smith@Teradyne.com Teradyne Assembly Test Division Website: www.teradyne.com/cbti
AXI AOI X-Ray Inspection ICT
Major Components • 1.X-ray Tube • Produces high resolution x-ray • beam cone PCB • 2. Image Intensifier / Detector • Converts radiation into visible light • 3. Camera • Sends video signal to computer • 4. Computer • Analyzes Image Imaging Analysis
Penetration Density and Thickness PCB’s & Solder Joint materials block x-rays based on: • Material Density(Lead, Copper, Plastics, Heat Sinks, etc.) • Material Thickness t Lightest - Darkest
60 128 200 250 Computer prefer a gray scale (0-255) X-ray Image
Smaller FOV Higher Resolution Larger FOV Low Resolution Field of View (FOV) • FOV Influences: • Test Throughput • Resolution / Detection • Clearance 1.0 in 25.4mm .25 in 6.4 mm .5 in 12.7 mm
Resolution • Resolution is measured as Line Pairs • X-ray Tube spot size • Detector resolution • Field of View • Resolution Influences • Clarity of image • Measurement repeatability • Detection capabilities • False calls .5in (12.5mm) FOV 1in (25mm) FOV
Types of X-ray Imaging • Transmission Imaging • Automated X-ray Inspection Systems (AXI) • Cross-Section Imaging • AXI Systems • Digital Tomosynthesis • Off-set Transmission • Laminography
Automatic X-Ray Inspection Technology Evolution Xstation 4000 ‘94 1st Digital Tomosynthesis AXI NIS MV6100 ‘86 1st Commercial AXI IRT CXI-5300 ‘97 NIS CXI-5700 ‘89 1st In-line AXI IRT CXI-3300 ‘98 NIS CXI-3600DG ‘94 IRT CXI-3600 ‘ 94 4pi 5DX ‘98 HP 5DX Series 2 ‘00 Agilent 5DX Series 3 ‘89 1st Laminography AXI 4pi 3DX Teradyne Acquires GenRad IRT Licenses X-ray Laminography to 4pi NIS acquires IRT 4 Pi Formed (spins off from IRT) GenRad acquires NIS HP invests in 4 Pi HP acquires 4 Pi ‘85 ‘87 ‘89 ‘91 ‘93 ‘95 ‘97 ‘99 ‘01 ‘03
Transmission AXI X-ray Image
Types of Cross-Section Imaging • Tomosynthesis • Digital Image Synthesis • Laminography • Mechanical Image Integration Generate Off-axis X-rays Generate Off-axis X-rays Stationary Detector Rotating Detector
Principle of Laminography • * Z-Axis Mapping required
Principle of Laminography • Steer-able x-ray source and rotating detector • “Smear/Average” out objects above/below focal plane • Mechanical integration generates one slice per rotation (or acquisition) • Image acquisition and synthesis occur concurrently Off-axis images
Steer-ableX-Ray Source Inspection Plane Large AreaDetector Principle of Digital Tomosynthesis Multiple Transmission Images
Principle of Digital Tomosynthesis Digital Tomosynthesis is a Computational Technique Z= X / tan Z • Objects at different elevations move by • different horizontal distances X
Digital Tomosynthesis is a Computational Technique Z= X / tan Z • Objects at different elevations move by • different horizontal distances X Principle of Digital Tomosynthesis
Top Side QFP PCB Resistor Bottom Side Principle of Digital Tomosynthesis Cross Section x-ray provides the capability to generate un-obscured views of top and bottom side components Use multiple off-axis x-ray images to separate top/bottom overlapping or obscured solder connections
Tomosynthesis vs. Laminography Tomosynthesis Laminography [Max Value Method] [Average Method] Some Digital Blurring Compared to Transmission AXI
Imaging Performance Examples • Transmission AXI • Resolution • ~ 20 lp/mm at 1.21 Sq-in FOV • Image noise 4.5% • Laminography AXI • resolution • ~ 8lp/mm at 0.64 Sq-in FOV • Image noise 7.5%
LaminographyAXI Transmission AXI Imaging Performance Better image quality and lower noise reduce false fails and increases fault detection.
1 1 2 3 4 Tomosynthesis vs. Laminography • Tomosynthesis • Multiple Cross-sections per Acquisition: ‘infinite slicing’ • Laminography • Laser Mapping to focus on layer • 1 Cross-section per Acquisition • board warp • board bounce & vibration • laser map repeatability
Flat to a 3D representation GULLWING SOLDER JOINT X-RAY IMAGE Heel Fillet Transmission Solder Joint Histogram
Adoption of Standards - IPC 7-32 • IPC 610 • Human Inspection Solder Joint Acceptability • IPC 7-32 Subcommittee (Automated Inspection Technologies) • Working with the IPC 610 Subcommittee • Translate the IPC 610 solder joint acceptability into language that is directly measurable by automatic inspection • Team will study the reliability of lead free joints through thermo-cycling • www.ipc.org
Void MeasurementA potential problem with Lead Free manufacturing process
Void Measurement Calculations can vary • Void Area = 31 pixels • Radius = 12 pixels • ( 12 * 12 ) * = 452.4 = 6.85% • Void Area = 60 pixels • Narrow Radius = 12 pixels • Wide Radius = 16 pixels • Circle = ( 12 * 12 ) * = 452.16 = 13.26% • Oval = ( 12 * 16 ) * = 603 = 9.85%
Void Issues Related to Ball Shape X-ray source • Similarly sized voids in may appear to vary in size • Side voids appear brighter and thus larger because rays travel thru a shorter distance through the ball • Voids at mid-ball appear darker or smaller as x-rays travel through more solder than at the sides
Issues with Voids Multiple small and misshaped voids looks similar
Measure Void Accuracy • Use real voids from production boards and grind the ball to detail actual void size. • Correlation between actual and void measurements were made.
AXI AOI 30 mm QFP BGA 20 mm TAB 15 mm COB CSP FC 10 mm (.4 in.) Technology Summary • AXI Vs other inspection techniques • Hidden joints Vs Visible Joints • 2D Vs Shape and Volume. ICT
Technology Summary • Transmission • Sharpe images • Reduces False Pass/Failure. • Can measure relative shape and volume • Large FOV • High Throughput • Can not easily resolve obscured solder joint • Solder joints on both sides of the board
Technology Summary • Laminography • Resolve most obscured solder joints • Averaging produces “smeared” images • Increases False Pass/Fail • Mechanical tolerances “smearing” effect • Increases False Pass/Fail • Smaller FOV or larger pixel detector can help reduce “smearing” • But Reduces throughput • Requires Z Axis mapping • Reduces throughput
Technology Summary • Digital Tomosynthesis • Resolve most obscured solder joints • Most of the advantages of Transmission AXI • Maximum image values produces sharper images • Minimise false pass/fail • Can have long image acquisition times • Reduce Throughput • Image processing has to take advantage of Moore’s Law. • Throughput issue
“Understanding AXI Acquisition Techniques and Image Quality” Michael J Smith Michael.J.Smith@Teradyne.com Teradyne Assembly Test Division Website: www.teradyne.com/cbti