150 likes | 272 Views
AurorA2000 Presentation. 6/14/2001 Chris Stevens, Engineering Engineering Department Vicon Industries Inc. Overview. Review of AurorA99 Setup AurorA2000 setup with AuroraNet Use of the V800MIU-3 New V1400X-DVC-3 (System Console) Screens New AurorA2000 Termination Setup.
E N D
AurorA2000 Presentation 6/14/2001 Chris Stevens, Engineering Engineering Department Vicon Industries Inc.
Overview • Review of AurorA99 Setup • AurorA2000 setup with AuroraNet • Use of the V800MIU-3 • New V1400X-DVC-3 (System Console) Screens • New AurorA2000 Termination Setup
Review of AurorA99 Setup Maximum RS-485 connections: 8 System Consoles/V800KBDs 8 MIUs (each containing a maximum of 4 devices) Or 32 MIUs (each containing one device maximum)
AurorA2000 Setup Maximum AurorANet (RS-485) connections: 79 total additional devices 16 System Consoles/A2K-KBDs 32 AurorA2000s 8 MIUs (each containing a maximum of 4 devices) Or 32 MIUs (each containing one device maximum)
Configuring Serial Ports For AurorANet: Mode: AurorANet Baud Rate: 9600 bps Data Bits: 8 Parity Bits: None Stop Bits: 1 Type: RS-485
AurorANet Protocol Note: The preferred method is using the provided AurorANet Termination Box.