An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Troubleshooting using the DTE-port

  2. PC LAN settings • The PC must be in the same subnet as the IP Office. • The PC must have a static IP address if recovering the unit from no or corrupt operational software on the unit (i.e. ip500.bin).

  3. Enable BootP and TFTP Servers • In Manager the BootP and TFTP Servers have to be selected.

  4. Utilization of the DTE Port for Maintenance Purposes BOOTP and network address are important settings in the Manager on the PC used for maintenance tasks.

  5. Utilization of the DTE Port for Maintenance Purposes • Prior to beginning tasks involving the DTE port, be sure to have access to a current data backup of customer data.

  6. Terminal Settings Settings for HyperTerminal

  7. Utilization of the DTE Port for Maintenance Purposes Deleting the configuration

  8. Utilization of the DTE Port for Maintenance Purposes • Deletion and reload of the operating system software can be forced using the DTE port.

  9. Utilization of the DTE Port for Maintenance Purposes It is possible to only reset the security settings.

  10. Using the IP Office 500 Reset Button • At the rear of the IP Office 500 system is a RESET button. • This button, when held for the relevant time period, performs the following functions:

  11. IP500v2 Control Unit The RESET button in the Control Unit IP500v2 has the same functions as in the IP 500 on the previous slide IP500v2 control units have an AUX button. This button can be used as follows.: If pressed during a restart of the control unit, the control unit skip booting from the /primary folder on the System SD card. If pressed for between 5 and 10 seconds when a system is running, the control unit will shutdown for 10 minutes.