1 / 36

Part 1910 Subpart D - Walking-Working Surfaces

Part 1910 Subpart D - Walking-Working Surfaces. 1910.21 - Definitions. 1910.22 - General requirements. 1910.23 - Guarding floor and wall openings and holes. 1910.24 - Fixed industrial stairs. 1910.25 - Portable wood ladders. 1910.26 - Portable metal ladders. 1910.27 - Fixed ladders.

fanniej
Download Presentation

Part 1910 Subpart D - Walking-Working Surfaces

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Part 1910 Subpart D - Walking-Working Surfaces • 1910.21 - Definitions. • 1910.22 - General requirements. • 1910.23 - Guarding floor and wall openings and holes. • 1910.24 - Fixed industrial stairs. • 1910.25 - Portable wood ladders. • 1910.26 - Portable metal ladders. • 1910.27 - Fixed ladders. • 1910.28 - Safety requirements for scaffolding. • 1910.29 - Manually propelled mobile ladder stands and scaffolds (towers). • 1910.30 - Other working surfaces.

  2. Subpart D - Walking/Working Surfaces (1910.21 - 32) Open sided Floors - 640 23(c)(1) Housekeeping - 198 22(a)(1) Wet Floors - 139 22(a)(1) Stair rails - 93 24(h) Floor holes - 86 23(a)(8) Number of Serious Violations - FY 98

  3. 1910.21(a)(1) & (a)(2) - Floor hole vs floor opening

  4. Floor Covering

  5. 1910.22(a)(1) Housekeeping

  6. 1910.22(a)(1) All places of employment, passageways, storerooms, service rooms shall be kept clean and orderly and in a sanitary condition.

  7. Debris on floor

  8. Housekeeping

  9. 1910.22(a)(2) - Floors Where wet processes are used, keep floors clean and dry as possible

  10. 1910.22(a)(3) - Protruding nails

  11. 1910.22(b) - Aisles and passageways (1) Safe clearances; clean and good repair; no obstacles in aisles where mechanical handling equipment is used. (2) Aisles and passageways shall be permanently marked

  12. 1910.22(d) - Floor loading protection (1) Loads approved by building official shall be marked.

  13. 1910.22(d) (continued) (1) Signs shall be marked & affixed in conspicuous place (2) Unlawful to overload

  14. 1910.23 - Guarding floor and wall openings and holes

  15. 1910.23(a)- Protection for floor openings (1) Every stairway floor opening shall be guarded by a standard railing constructed in accordance with paragraph (e) of this section. Guard Rail System

  16. Types of materials

  17. 1910.23(a)(2) - Ladderway floor openings, platforms - • Guarded by standard railing, toeboard

  18. 1910.23(a)(3) Hatchway/chute floor opening • Guarded by hinged cover or removable railing/toeboard

  19. 1910.23(a)(4) Skylight floor opening Guarded by standard skylight screen/or fixed standard railing

  20. Protected sky light

  21. 1910.23(a)(6) Manhole floor opening - Guarded by standard manhole cover

  22. 1910.23(a)(8) Floor hole opening - Guarded by standard railing/cover

  23. 1910.23(a)(8)(ii) - Floor hole opening

  24. 1910.23(b) - Wall openings/holes (1) Drop greater than 4’ shall be guarded

  25. 1910.23(c)(1) Open sided floors, platforms and runways

  26. Work platform

  27. Work platform

  28. Elevated runway

  29. Adequate platform guardrail

  30. What’s the problem here?

  31. What’s up with this???

  32. 1910.23(c)(3) Adjacent to dangerous equipment (regardless of height) - Guarded by standard railing with toeboard Open screw auger directly underneath

  33. QUESTIONS ?

More Related