1 / 24

STEMming up pGlo™

STEMming up pGlo™. Bio-Rad Biotechnology Explorer™ pGlo Kit. Instructors - Bio-Rad Curriculum and Training Specialists. Sherri Andrews, Ph.D. sherri_andrews@bio-rad.com Damon Tighe, damon_tighe@bio-rad.com Leigh Brown, M.A. leigh_brown@bio-rad.com. The Problem and the Constraints.

farica
Download Presentation

STEMming up pGlo™

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. STEMming up pGlo™ Bio-Rad Biotechnology Explorer™ pGlo Kit

  2. Instructors - Bio-Rad Curriculum and Training Specialists Sherri Andrews, Ph.D. sherri_andrews@bio-rad.com Damon Tighe, damon_tighe@bio-rad.com Leigh Brown, M.A. leigh_brown@bio-rad.com

  3. The Problem and the Constraints • The Problem • Develop a STEM lab experience using the pGlo kit • The Contraints • Personnel • Time – Must be done by NSTA Nationals • Money – Must not require lots of expensive equipment or reagents • Fun factor – Must be fun and interesting (at least to the personnel doing it and hopefully also to educators and students!)

  4. A Case Study of doing a Case Study! • Study the impact of transformation temperature on transformation efficiency

  5. Heat shock at42ºC or 52ºCfor 50 seconds, place on ice for 2 minutes + Digital dry bath 2 ml tube block 42ºC Control 52ºC Test The Quick and Dirty • Time was one of the personnel’s biggest constraints so designed quick and simple experiment to detect impact of transformation temperature on transformation efficiency Why use the dry bath? It’s digital and easy to set the temperature It was on my lab bench…

  6. The Quick and Dirty continued… Heat shocked at 52ºC Heat shocked at 42ºC LB/Amp/Ara Plates ? 42ºC result 52ºC result N=3 for each condition

  7. When in doubt…repeat • Theory – 52ºC was not quite warm enough to kill off the E. coli so still got decent transformation • Experiment – More is better! Increase heat shock temperature to 60ºC or even 75ºC! Heat shock at42ºC or 60ºC or 75ºCfor 50 seconds, place on ice for 2 minutes + Digital dry bath 2 ml tube block What do you predict the results will be?

  8. Results 42ºC Heat shock 60ºC Heat shock 75ºC Heat shock N=3 for each condition ???

  9. What is going on??? • For HB101 E. coli, heat shock is most efficient at 42ºC (published results) • HB101 E. coli should die at 75ºC! • Using a dry bath, the best transformation efficiency occurred when the temperature of the block was set to 75ºC

  10. Experimental – What is impacting transformation efficiency in my experiments? • Design, construct and test a system which will result in the best transformation efficiency using what you know about thermal energy transfer • Possible devices include • Water bath, glass beaker, styrofoam cup, plastic cup containing water at a specified temperature • Dry bath • Sand bath maintained at a certain temperature • Incubator at a set temperature

  11. STEM in Action • Problem – Increase the transformation efficiency of the pGlo plasmid into HB101 by experimenting with heat shock transformation conditions • Constraints – Use equipment and reagents already in existence in the laboratory or which can be inexpensively built

  12. STEM – Science • Understanding normal living conditions of HB101 E. coli • Understanding cell membrane structures • Understanding transformation and how it works

  13. STEM – Technology • Measurement devices • Heating implements • Calculation and analysis

  14. STEM – Engineering • Heat transfer • Conduction • Convection • Thermal conductivity

  15. Test the device and calculate transformation efficiency • Test the device to see if transformation occurs and determine efficiency of transformation • If no transformation occurs, identify reasons which impacted efficiency • Identify and control variables such as number of E. coli, amount of plasmid (loop vs. pipet), temperature of heat shock, instruments used

  16. Develop Models Measure the temperature of 250 µl Transformation solution after 50 seconds when heated in the device being used 50ºC 60ºC 45ºC All instruments were set to 75ºC

  17. Develop models continued • Measure the temperature a series of locations of a frozen item thawing in a warm location • Measure the temperature of a wet item in a cold location and then in a cold location with wind blowing over it (or talk about wind chill factors) • Look up and discuss thermal conductivity values • Measure the temperature of sand warmed from above at different heights from the surface

  18. Develop models • Crisco or coconut oil on top of water with a washer on top • Heat up • Cool down • See what happens! • Insert photos here…

  19. STEM – Math • Calculate conductive heat transfer through water versus sand if the Transformation solution is at 20ºC, the water bath is 42ºC, the wall thickness is 0.002 m, and the thermal conductivity is assumed to be just based on the properties of sand or water q / A = k dT / s where  q / A = heat transfer per unit area (W/m2) k = thermal conductivity  (W/mK) dT = temperature difference (ºC) s = wall thickness (m) • Calculate heat transfer per unit area through water if the water temperature is set to 42ºC versus 60ºC

  20. STEM – Math Calculate rates of heat change using the different heating devices

  21. Volume spread (µl) x DNA in transformation (µg) DNA spread on the plate (µg) = 10 µl x 0.05 µg = Total volume of transformation (µl) 500 µl = 0.001 µg 60 CFU 0.001 µg STEM – Math • Calculate the transformation efficiency • Count the number of colonies on the plate = CFU (colony forming units) For this example, let’s assume you counted 60 colonies • Determine the amount of DNA (in µg) spread on the plate • Finally, calculate the transformation efficiency by dividing the number of colonies on the plate (CFU) by the amount of DNA (in µg) spread on the plate Transformation efficiency = 60,000 CFU/µg = 6 x 105 CFU/µg =

  22. Final results of STEM experiment… • Better controlled experiment • Prepared one tube of resuspended cells in transformation solution and aliquoted to several tubes to insure same cell density in each • Using model system of just transformation solution, measured temperature that cells would reach for heat shock

  23. Some conclusions • HB101 in this case had a higher transformation efficiency in a waterbath set at 60ºC for 50 seconds of heat shock • HB101 had decreasing transformation efficiency if allowed to sit at a higher temperature for too long • The heating implement can have a direct impact on the results due to heat exchange properties!

  24. Relation to other science and the real world • Why do we have to study this?? • PCR thin walled tubes • Wind chill factor (convection versus conduction) • Convection ovens (how come you can cook faster?) • Do you get colder if you are standing outside without a jacket when it is -10ºC versus +10ºC? Why? What is the driving force to become colder? • Why does the USDA recommend cooking hamburger meat until 160ºF (71ºC)? What temperature kills bacteria? • What it the purpose of a fever? What temperature kills bacteria? What is thermal death time versus thermal death point?

More Related