1 / 16

The 2-channel focal reducer (FoReRo2): a new observing facility for the 2-meter telescope

The 2-channel focal reducer (FoReRo2): a new observing facility for the 2-meter telescope. Tanyu Bonev Institute of Astronomy Bulgarian Academy of Sciences. Optical parameters Mechanical design Modes of observations with examples Conclusions.

fayola
Download Presentation

The 2-channel focal reducer (FoReRo2): a new observing facility for the 2-meter telescope

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. The 2-channel focal reducer (FoReRo2): a new observing facility for the 2-meter telescope Tanyu Bonev Institute of Astronomy Bulgarian Academy of Sciences • Optical parameters • Mechanical design • Modes of observations with examples • Conclusions

  2. 16 m Focal length 5.6 m f/8 f ratio f/2.8 0.31 arcsec/px Scale (1 px = 0.024 mm) 0.88 arcsec/px

  3. FoReRo2: Modes of Observations • Broadband imaging • Narrowband imaging • Long slit spectroscopy • Fabry-Perot imaging • Imaging polarimetry

  4. FoReRo2: Broad band imaging and photometry Available Filters: U, B, V, R, I Example: Landolt field PG1633+099, filter V, Exposure = 15 sec

  5. FoReRo2: long slit spectrography Grating prisms (grisms) Blue ChannelRed Channel 600 lines/mm300 lines/mm 0.3 nm/px0.5 nm/px Long slit: Length: covers the full FOV Width: 110 microns = 1.5 arcsec

  6. FoReRo2: long slit spectrography Blue ChannelRed Channel < 445 nm> 490 nm

  7. FoReRo2: low dispersion spectra Blue ChannelRed Channel < 445 nm> 490 nm

  8. FoReRo2: Fabry-Perot Imaging

  9. FoReRo2: Fabry-Perot Imaging interferogram of [OI] 6300 in comet Q4 (NEAT), obtained on May 23, 2004. Interference filter + 500 micron Fabry-Perot etalon in the red channel. Exposure: 600 sec [OI] 6300 night sky emission

  10. FoReRo2: Imaging polarimetry mode Comet Q4 (NEAT) Optical arrangement 90o +45o -45o 0o

  11. FoReRo2: Narrow band imaging Part of the available interference filters

  12. Narrow band imaging of comet Q4 (NEAT) On-line, 616 nm, H2O+ Off-line, 642 nm, Continuum - k *

  13. Comet Q4 (NEAT), May 26, 2004 H2O+ ions in the near nucleus region

  14. Comet Q4 (NEAT), May 26, 2004 Dynamics of the H2O+ ions in the near nucleus region 11 frames x 300 sec exposure Total time of the sequence < 1 h

  15. FoReRo2: Conclusions • The 2-channel focal reducer increases the power of the 2-meter telescope by: • Changing the f ratio from f/8 to f/2.8 • Allowing simultaneous data acquisition in two spectral ranges • The 2-channel focal reducer offers several modes of observations: • Broad band imaging • Narrow band imaging • Long slit spectroscopy • Fabry-Perot imaging • Imaging polarimetry

More Related