1 / 7

Intensive water and chemistry flux site : paired canopy and open-canopy sites

Intensive water and chemistry flux site : paired canopy and open-canopy sites. Water flux site: paired canopy and open-canopy sites. Throughfall. Temp/RH. Pyronmeter. - H 2 O content/ Temp/EC H 2 O potential Prenart lysimeters. - H 2 O content/ Temp. 10, 30,45+ cm depths.

Download Presentation

Intensive water and chemistry flux site : paired canopy and open-canopy sites

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Intensive water and chemistry flux site: paired canopy and open-canopy sites Water flux site: paired canopy and open-canopy sites Throughfall Temp/RH Pyronmeter • - H2O content/ • Temp/EC • H2O potential • Prenart • lysimeters - H2O content/ Temp 10, 30,45+ cm depths Wick lysimeter

  2. Intensive water and chemistry flux site: paired canopy and open-canopy sites Water flux site: paired canopy and open-canopy sites Throughfall Temp/RH Pyronmeter • - H2O content/ • Temp/EC • H2O potential • Prenart • lysimeters - H2O content/ Temp 10, 30,60+ cm depths Wick lysimeter Piezometer cluster Overland flow sampler Downslope convergent zone and stream Automatic water sampler

  3. Overview List of equipment: Culvert: onset pressure transducer (streamflow) C-High: pressure transducer @ 100cm 1-High: pressure transducer @ 100cm 1-Low: pressure transducer @ 100cm 2-High: pressure transducer @ 100cm 2-Low: pressure transducer @ 100cm Notes: -Cluster 1 and 2 are co-located with sapflow measurements. -Additional instrumentation near the tower and regeneration stand need to be added

  4. List of equipment: J1-1: 5TE (10, 30, 60+cm), MPS1 (10, 30 cm), Prenart (10, 30, 60+ cm), pyronmeter, T/RH, Judd J2-1: same at J1-1 J3-1: 5TM (10, 30, 60+cm), pyronmeter, T/RH, Judd J4-1: same as J3-1 J5-1: same as J3-1 J6-1: same as J3-1 Notes: -5TE measures soil moisture, temperature, and EC -5TM measures soil moisture and temperature -MPS1 measures matric potential -Prenart samples soil water -Pyronometer measures solar radiation -Judd measures snow depth -Tipping buckets in and out of canopy Grey Stand – Cluster 1

  5. Red Stand – Cluster 2 List of equipment: J1-2: 5TE (10, 30, 60+cm), MPS1 (10, 30 cm), Prenart (10, 30 cm), pyronmeter, T/RH, Judd J2-2: same at J1-2 J3-2: 5TM (10, 30, 60+cm), pyronmeter, T/RH, Judd J4-2: same as J3-2 J5-2: same as J3-2 J6-2: same as J3-2 Notes: -5TE measures soil moisture, temperature, and conductivity -5TM measures soil moisture and temperature -MPS1 measures matric potential -Prenart samples soil water -Pyronometer measures solar radiation -Judd measures snow depth -Tipping buckets in and out of canopy

  6. List of equipment: J1: EC5 (10, 30, 60+cm), CSI temp (10, 30, 60+ cm), MPS1 (10, 30cm) Prenart(10 cm), piezometer, pyronmeter, T/RH, Judd J2: same as J1 with Prenart at 10 and 30 cm J3: EC5 and CSI temp (10, 30, 60+cm), pyronmeter, T/RH, Judd J4: same as J3 J5: same as J1 J6:same as J1 with no piezometer J7: Judd, T/RH, and pyronometer J8: same as J1 Notes: -EC5 measures soil moisture and temperature -MPS1 measures matric potential -Prenart samples soil water -Judd measures snow depth Green Stand – Niwot Ridge

More Related